NFPA 30:2024
Current
The latest, up-to-date edition.
Flammable and Combustible Liquids Code
Hardcopy
English, Spanish, Castilian
13-05-2023
Chapter 1 Administration
1.1 Scope.
1.2 Purpose.
1.3 Application.
1.4 Retroactivity.
1.5 Equivalency.
1.6 Symbols, Units, and Formulas.
1.7 Code Adoption Requirements. (Reserved)
1.8 Permits. (Reserved)
1.9 Enforcement.
Chapter 2 Referenced Publications
2.1 General.
2.2 NFPA Publications.
2.3 Other Publications.
2.4 References for Extracts in Mandatory Sections.
Chapter 3 Definitions
3.1 General.
3.2 NFPA Official Definitions.
3.3 General Definitions.
Chapter 4 Classification of Liquids
4.1 Scope.
4.2 Classification Scheme.
4.3 Determination of Boiling Point (BP).
4.4 Determination of Flash Point (FP).
Chapter 5 General Requirements (Reserved)
Chapter 6 Fire and Explosion Prevention and Risk Control
6.1 Scope.
6.2 Definitions Specific to Chapter 6. (Reserved)
6.3 Management of Fire and Explosion Hazards.
6.4 Hazards Analysis.
6.5 Control of Ignition Sources.
6.6 Detection and Alarm Systems and Procedures.
6.7 Fire Protection and Fire Suppression Systems.
6.8 Explosion Protection Systems.
6.9 Emergency Planning and Training.
6.10 Inspection and Maintenance.
6.11 Management of Security.
6.12 Containment, Drainage, and Spill Control.
Chapter 7 Electrical Systems
7.1 Scope.
7.2 Definitions Specific to Chapter 7. (Reserved)
7.3 General Requirements.
7.4 Application of Area Classification.
Chapter 8 Reserved
Chapter 9 Storage of Ignitible (Flammable or Combustible) Liquids in Containers — General Requirements
9.1 Scope.
9.2 Definitions Specific to Chapter 9.
9.3 General Requirements.
9.4 Acceptable Containers.
9.5 Liquid Storage Cabinets.
9.6 Maximum Allowable Quantities (MAQs) per Control Area.
9.7 Control Areas.
9.8 Classification of Occupancies That Exceed the Maximum Allowable Quantities of Ignitible (Flammable or Combustible) Liquids per Control Area.
9.9 Construction Requirements.
9.10 Fire Protection.
9.11 Emergency Control Systems.
9.12 Electrical Systems.
9.13 Containment, Drainage, and Spill Control.
9.14 Ventilation.
9.15 Exhausted Enclosures. (Reserved)
9.16 Explosion Control.
9.17 Separation from Incompatible Materials.
9.18 Dispensing, Handling, and Use of Ignitible (Flammable or Combustible) Liquids in Storage Areas.
9.19 Outdoor Storage of Ignitible (Flammable or Combustible) Liquids.
Chapter 10 Storage of Ignitible (Flammable or Combustible) Liquids in Containers — Mercantile Occupancies
10.1 Scope.
10.2 Definitions Specific to Chapter 10. (Reserved)
10.3 General Requirements.
10.4 Reserved.
10.5 Reserved.
10.6 Reserved.
10.7 Control Areas.
10.8 Specific Restrictions.
10.9 Construction Requirements.
10.10 Fire Protection.
10.11 Emergency Control Systems. (Reserved)
10.12 Electrical Systems.
10.13 Containment, Drainage, and Spill Control.
10.14 Ventilation.
10.15 Exhausted Enclosures. (Reserved)
10.16 Explosion Control.
10.17 Separation from Incompatible Materials.
10.18 Dispensing, Handling, and Use of Ignitible (Flammable or Combustible) Liquids in Mercantile Occupancies.
10.19 Outdoor Storage of Ignitible (Flammable or Combustible) Liquids.
Chapter 11 Storage of Ignitible (Flammable or Combustible) Liquids in Containers — Industrial Occupancies
11.1 Scope.
11.2 Definitions Specific to Chapter 11. (Reserved)
11.3 General Requirements.
Chapter 12 Storage of Ignitible (Flammable or Combustible) Liquids in Containers — Storage Occupancies
12.1 Scope.
12.2 Definitions Specific to Chapter 12.
12.3 General Requirements.
12.4 Reserved.
12.5 Reserved.
12.6 Maximum Allowable Quantities and Maximum Storage Heights.
12.7 Control Areas.
12.8 General-Purpose Warehouses.
12.9 Construction Requirements.
12.10 Fire Protection.
12.11 Emergency Control Systems. (Reserved)
12.12 Electrical Systems.
12.13 Containment, Drainage, and Spill Control.
12.14 Ventilation.
12.15 Exhausted Enclosures. (Reserved)
12.16 Explosion Control.
12.17 Separation from Incompatible Materials.
12.18 Dispensing, Handling, and Use of Ignitible (Flammable or Combustible) Liquids in Storage Occupancies.
12.19 Outdoor Storage of Ignitible (Flammable or Combustible) Liquids.
Chapter 13 Storage of Ignitible (Flammable or Combustible) Liquids in Containers — Detached, Unprotected Buildings
13.1 Scope.
13.2 Definitions Specific to Chapter 13. (Reserved)
13.3 General Requirements.
13.4 Reserved.
13.5 Reserved.
13.6 Maximum Allowable Quantities and Maximum Storage Heights.
13.7 Control Areas. (Reserved)
13.8 Reserved.
13.9 Construction Requirements.
13.10 Fire Protection.
13.11 Emergency Control Systems. (Reserved)
13.12 Electrical Systems.
13.13 Containment, Drainage, and Spill Control.
13.14 Ventilation.
13.15 Exhausted Enclosure. (Reserved)
13.16 Explosion Control.
13.17 Separation from Incompatible Materials.
13.18 Dispensing, Handling, and Use of Ignitible (Flammable or Combustible) Liquids in Detached, Unprotected Buildings.
13.19 Outdoor Storage of Ignitible (Flammable or Combustible) Liquids.
Chapter 14 Hazardous Materials Storage Lockers
14.1 Scope.
14.2 Definitions Specific to Chapter 14. (Reserved)
14.3 General Requirements.
14.4 Design and Construction of Hazardous Materials Storage Lockers.
14.5 Designated Sites for Hazardous Materials Storage Lockers.
14.6 Storage Requirements.
Chapter 15 Outdoor Storage
15.1 Scope.
15.2 Definitions Specific to Chapter 15. (Reserved)
15.3 General Requirements.
15.4 Outdoor Storage Adjacent to a Building.
Chapter 16 Automatic Fire Protection for Control Areas, Liquid Storage Rooms, and Liquid Warehouses
16.1 Scope.
16.2 Definitions Specific to Chapter 16.
16.3 General Requirements.
16.4 Automatic Sprinkler and Foam-Water Sprinkler Fire Protection Systems.
16.5 Fire Protection System Design Criteria.
16.6 Fire Protection System Design Schemes.
16.7 Water Supply.
16.8 Containment, Drainage, and Spill Control.
16.9 Other Automatic Fire Protection Systems.
16.10 Distilled Spirits in Wooden Barrels.
Chapter 17 Processing Facilities
17.1 Scope.
17.2 Definitions Specific to Chapter 17. (Reserved)
17.3 General Requirements.
17.4 Location of Process Vessels and Equipment.
17.5 Accessibility.
17.6 Construction Requirements.
17.7 Fire Protection.
17.8 Emergency Control Systems.
17.9 Electrical Systems.
17.10 Containment, Drainage, and Spill Control.
17.11 Ventilation.
17.12 Explosion Control.
17.13 Process Structures. (Reserved)
17.14 Process Equipment and Vessels.
17.15 Management of Operations Hazards.
Chapter 18 Dispensing, Handling, Transfer, and Use of Ignitible (Flammable or Combustible) Liquids
18.1 Scope.
18.2 Definitions Specific to Chapter 18. (Reserved)
18.3 General Requirements.
18.4 Dispensing, Handling, Transfer, and Use.
18.5 Incidental Operations.
18.6 Ventilation for Dispensing Areas.
Chapter 19 Specific Operations
19.1 Scope.
19.2 Definitions Specific to Chapter 19.
19.3 General Requirements. (Reserved)
19.4 Recirculating Heat Transfer Systems.
19.5 Vapor Recovery and Vapor Processing Systems.
19.6 Solvent Distillation Units.
19.7 Cooking Oil Storage Tank Systems in Commercial Kitchens.
Chapter 20 Reserved
Chapter 21 Storage of Ignitible (Flammable or Combustible) Liquids in Tanks — Requirements for All Storage Tanks
21.1 Scope.
21.2 Definitions Specific to Chapter 21.
21.3 General Requirements.
21.4 Design and Construction of Storage Tanks.
21.5 Testing Requirements for Tanks.
21.6 Fire Prevention and Control.
21.7 Operation of Storage Tanks.
21.8 Inspection and Maintenance of Storage Tanks and Storage Tank Appurtenances.
21.9 Change of Stored Liquid.
Chapter 22 Storage of Ignitible (Flammable or Combustible) Liquids in Tanks — Aboveground Storage Tanks
22.1 Scope.
22.2 Definitions Specific to Chapter 22.
22.3 General Requirements.
22.4 Location of Aboveground Storage Tanks.
22.5 Installation of Aboveground Storage Tanks.
22.6 Vent Piping for Aboveground Tanks.
22.7 Emergency Relief Venting for Fire Exposure for Aboveground Storage Tanks.
22.8 Fire Protection for Aboveground Storage Tanks.
22.9 Additional Requirements for Fire-Resistant Aboveground Storage Tanks.
22.10 Additional Requirements for Protected Aboveground Storage Tanks.
22.11 Control of Spills from Aboveground Storage Tanks.
22.12 Equipment, Piping, and Fire Protection Systems in Remote Impoundment Areas and Diked Areas.
22.13 Tank Openings Other than Vents.
22.14 Aboveground Storage Tanks Located in Areas Subject to Flooding.
22.15 Collision Protection for Aboveground Storage Tanks.
22.16 Installation Instructions for Aboveground Storage Tanks.
22.17 Inspection and Maintenance of Aboveground Storage Tanks.
Chapter 23 Storage of Ignitible (Flammable or Combustible) Liquids in Tanks — Underground Tanks
23.1 Scope.
23.2 Definitions Specific to Chapter 23. (Reserved)
23.3 General Requirements.
23.4 Location of Underground Storage Tanks.
23.5 Installation of Underground Storage Tanks.
23.6 Normal Venting for Underground Storage Tanks.
23.7 Reserved.
23.8 Reserved.
23.9 Reserved.
23.10 Reserved.
23.11 Control of Spills from Underground Storage Tanks.
23.12 Reserved.
23.13 Tank Openings Other than Vents.
23.14 Underground Storage Tanks Located in Areas Subject to Flooding.
23.15 Reserved.
23.16 Installation Instructions for Underground Storage Tanks.
23.17 Inspection and Maintenance of Underground Storage Tanks.
Chapter 24 Storage Tank Buildings
24.1 Scope.
24.2 Definitions Specific to Chapter 24. (Reserved)
24.3 General Requirements. (Reserved)
24.4 Location of Storage Tank Buildings.
24.5 Construction of Storage Tank Buildings.
24.6 Fire Protection for Storage Tank Buildings.
24.7 Emergency Control Systems for Storage Tank Buildings. (Reserved)
24.8 Electrical Systems for Storage Tank Buildings.
24.9 Containment, Drainage, and Spill Control from Storage Tank Buildings.
24.10 Ventilation for Storage Tank Buildings.
24.11 Reserved.
24.12 Explosion Control.
24.13 Vents for Tanks Inside Storage Tank Buildings.
24.14 Tank Openings Other than Vents for Tanks Inside Storage Tank Buildings.
24.15 Detection and Alarm Systems for Storage Tank Buildings.
24.16 Inspection and Maintenance for Storage Tank Buildings.
Chapter 25 Storage Tank Vaults
25.1 Scope.
25.2 Definitions Specific to Chapter 25. (Reserved)
25.3 General Requirements.
25.4 Location of Storage Tank Vaults.
25.5 Construction and Installation of Storage Tank Vaults.
25.6 Fire Protection for Storage Tank Vaults.
25.7 Emergency Controls for Storage Tank Vaults. (Reserved)
25.8 Electrical Systems for Storage Tank Vaults.
25.9 Containment, Drainage, and Spill Control for Storage Tank Vaults.
25.10 Ventilation Systems for Storage Tank Vaults.
25.11 Reserved.
25.12 Explosion Control.
25.13 Vents for Tanks Inside Storage Tank Vaults.
25.14 Tank Openings Other than Vents for Tanks Inside Storage Tank Vaults. (Reserved)
25.15 Detection and Alarm Systems for Storage Tank Vaults.
25.16 Inspection and Maintenance of Storage Tank Vaults and Equipment.
Chapter 26 Petroleum Production Sites
26.1 Scope.
26.2 Definitions Specific to Chapter 26.
26.3 Tank Design Standards.
26.4 Identification for Emergency Responders.
26.5 Emergency Venting.
26.6 Operation and Maintenance.
26.7 Overfill Protection Requirements.
26.8 Security.
Chapter 27 Piping Systems
27.1 Scope.
27.2 Definitions Specific to Chapter 27.
27.3 General Requirements.
27.4 Materials of Construction for Piping Systems.
27.5 Pipe Joints.
27.6 Installation of Piping Systems.
27.7 Testing of Piping Systems.
27.8 Vent Piping.
27.9 Bonding and Grounding.
27.10 Identification and Marking of Piping Systems.
27.11 Special Requirements for Marine Piping Systems.
27.12 Removal from Service of Piping Systems.
Chapter 28 Bulk Loading and Unloading Facilities for Tank Cars and Tank Vehicles
28.1 Scope.
28.2 Definitions Specific to Chapter 28. (Reserved)
28.3 General Requirements.
28.4 Location of Loading and Unloading Facilities.
28.5 Roofed Structures.
28.6 Fire Protection. (Reserved)
28.7 Emergency Control Systems. (Reserved)
28.8 Electrical Systems.
28.9 Containment, Drainage, and Spill Control.
28.10 Equipment.
28.11 Operating Requirements.
Chapter 29 Wharves
29.1 Scope.
29.2 Definitions Specific to Chapter 29. (Reserved)
29.3 General Requirements.
Annex A Explanatory Material
Annex B Background on Ignitible (Flammable and Combustible) Liquid Nomenclature Change
Annex C Emergency Relief Venting for Fire Exposure for Aboveground Tanks
Annex D Temporarily Out of Service, Closure in Place, or Closure by Removal of Underground Storage Tanks
Annex E Development of Fire Protection System Design Criteria for Chapter 16 and Suggested Fire Protection for Some Containers of Ignitible (Flammable and Combustible) Liquids Not Covered in Chapter 16
Annex F Using Thermal Radiation Modeling for Tank Spacing
Annex G Suggested Test Protocol for Developing Fire Protection System Design Criteria for Containers of Ignitible (Flammable and Combustible) Liquids
Annex H Fugitive Emissions Calculations
Annex I Management of Security
Annex J Sample Ordinance Adopting NFPA 30
Annex K Informational References
This code shall apply to the storage, handling, and use of ignitible (flammable or combustible) liquids, including waste liquids, as herein defined and classified.
DevelopmentNote |
TIA 24-1, Reference: 6.8.2(4)(new), Issue date:29-Aug-2024
|
DocumentType |
Standard
|
Pages |
186
|
PublisherName |
National Fire Protection Association
|
Status |
Current
|
Supersedes |
NFPA 58:2024 | Liquefied Petroleum Gas Code |
NFPA 101:2024 | Life Safety Code |
NFPA 59:2024 | Utility LP-Gas Plant Code |
NFPA 45:2024 | Standard on Fire Protection for Laboratories Using Chemicals |
NFPA 5000:2024 | Building Construction and Safety Code |
NFPA 17:2024 | Standard for Dry Chemical Extinguishing Systems |
NFPA 76:2024 | Standard for the Fire Protection of Telecommunications Facilities |
NFPA 326:2025 | Standard for the Safeguarding of Tanks and Containers for Entry, Cleaning, or Repair |
NFPA 110:2025 | Standard for Emergency and Standby Power Systems |
NFPA 90A:2024 | Standard for the Installation of Air-Conditioning and Ventilating Systems |
NFPA 34:2024 | Standard for Dipping, Coating, and Printing Processes Using Flammable or Combustible Liquids |
NFPA 30A:2024 | Code for Motor Fuel Dispensing Facilities and Repair Garages |
NFPA 1960:2024 | Standard for Fire Hose Connections, Spray Nozzles, Manufacturer’s Design of Fire Department Ground Ladders, Fire Hose, and Powered Rescue Tools |
NFPA 418:2024 | Standard for Heliports and Vertiports |
NFPA 400:2025 | Hazardous Materials Code |
PIP VEETA001:2024 | Tank Selection Guide |
NFPA 31:2024 | Standard for the Installation of Oil-Burning Equipment |
NFPA 220:2024 | Standard on Types of Building Construction |
NFPA 59A:2023 | Standard for the Production, Storage, and Handling of Liquefied Natural Gas (LNG) |
NFPA 704:2022 | Standard System for the Identification of the Hazards of Materials for Emergency Response |
NFPA 31:2020 | Standard for the Installation of Oil-Burning Equipment |
NFPA 10:2022 | Standard for Portable Fire Extinguishers |
NFPA 37:2021 | Standard for the Installation and Use of Stationary Combustion Engines and Gas Turbines |
NFPA 5000:2021 | Building Construction and Safety Code |
NFPA 13 : 2022 | Standard for the Installation of Sprinkler Systems, 2022 and 2019 Editions |
NFPA 85:2023 | Boiler and Combustion Systems Hazards Code |
NFPA 68:2023 | Standard on Explosion Protection by Deflagration Venting |
NFPA 505 : 2018 | FIRE SAFETY STANDARD FOR POWERED INDUSTRIAL TRUCKS INCLUDING TYPE DESIGNATIONS, AREAS OF USE, CONVERSIONS, MAINTENANCE, AND OPERATIONS |
NFPA 221:2024 | Standard for High Challenge Fire Walls, Fire Walls, and Fire Barrier Walls |
NFPA 34:2021 | Standard for Dipping, Coating, and Printing Processes Using Flammable or Combustible Liquids |
NFPA 24:2022 | Standard for the Installation of Private Fire Service Mains and Their Appurtenances |
NFPA 96:2024 | Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations |
NFPA 45:2019 | Standard on Fire Protection for Laboratories Using Chemicals |
NFPA 307:2021 | Standard for the Construction and Fire Protection of Marine Terminals, Piers, and Wharves |
NFPA 58:2020 | Liquefied Petroleum Gas Code. |
NFPA 12:2022 | Standard on Carbon Dioxide Extinguishing Systems |
NFPA 326 : 2020 | Standard for the Safeguarding of Tanks and Containers for Entry, Cleaning, or Repair |
NFPA 33:2021 | Standard for Spray Application Using Flammable or Combustible Materials |
NFPA 11:2021 | Standard for Low-, Medium, and High-Expansion Foam |
NFPA 303:2021 | Fire Protection Standard for Marinas and Boatyards |
NFPA 750:2023 | Standard on Water Mist Fire Protection Systems |
NFPA 12A:2022 | Standard on Halon 1301 Fire Extinguishing Systems |
NFPA 99:2021 | Health Care Facilities Code |
NFPA 70:2023 | National Electrical Code (NEC) Softbound |
NFPA 14 : 2019 | Standard for the Installation of Standpipe and Hose Systems |
NFPA 32:2021 | Standard for Drycleaning Facilities |
NFPA 770:2021 | Standard on Hybrid (Water and Inert Gas) Fire Extinguishing Systems |
NFPA 25:2023 | Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems |
NFPA 35:2021 | Standard for the Manufacture of Organic Coatings |
NFPA 2001:2022 | Standard on Clean Agent Fire Extinguishing Systems |
NFPA 80:2022 | Standard for Fire Doors and Other Opening Protectives |
NFPA 30A:2021 | Code for Motor Fuel Dispensing Facilities and Repair Garages |
NFPA 69 : 2019 | Standard on Explosion Prevention Systems |
NFPA 20:2022 | Standard for the Installation of Stationary Pumps for Fire Protection |
NFPA 91:2020 | Standard for Exhaust Systems for Air Conveying of Vapors, Gases, Mists, and Particulate Solids |
NFPA 30B:2023 | Manufacture and Storage of Aerosol Products |
NFPA 101:2021 | Life Safety Code |
NFPA 1 : 2021 | FIRE CODE |
NFPA 15:2022 | Standard for Water Spray Fixed Systems for Fire Protection |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.