NF EN 61557-3 : 2007
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 3: LOOP IMPEDANCE
14-01-2023
12-01-2013
AVANT-PROPOS
1 Domaine d'application
2 Références normatives
3 Termes et définitions
4 Exigences
5 Marquages et instructions de fonctionnement
5.1 Marquage
5.2 Instructions de fonctionnement
6 Essais
Bibliographie
Annexe ZA (normative) Références normatives à d'autres
publications internationales avec les
publications européennes correspondantes
Defines the requirements applying to equipment for measurement of the loop impedance between a phase and protective conductor, or between a phase conductor and neutral or between two phase conductors by means of the voltage drop when the circuit being tested is loaded.
DevelopmentNote |
Indice de classement: C42-198-3PR. PR NF EN 61557-3 November 2005. (11/2005) PR NF EN 61557-3 April 2018. (05/2018)
|
DocumentType |
Standard
|
PublisherName |
Association Francaise de Normalisation
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
UNE-EN 61557-3:2007 | Identical |
IEC 61557-3:2007 | Identical |
I.S. EN 61557-3:2007 | Identical |
DIN EN 61557-3 : 2008 | Identical |
BS EN 61557-3:2007 | Identical |
NBN EN 61557-3 : 2007 | Identical |
EN 61557-3:2007 | Identical |
SN EN 61557-3 : 1997 | Identical |
NF EN 61557-1 : 2007 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 1: GENERAL REQUIREMENTS |
NF EN 61557-1 : 2007 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 1: GENERAL REQUIREMENTS |
IEC 61557-1:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 1: General requirements |
NF EN 61010-1 : 2011 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
IEC 61010-1:2010+AMD1:2016 CSV | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.