• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

MIL-STD-2003-2 Revision A:2009

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Electric Plant Installation Standard Methods for Surface Ships and Submarines (Equipment)

Available format(s)

PDF

Language(s)

English

Published date

03-09-2009

Superseded date

06-10-2020

£15.19
Excluding VAT

1. SCOPE
2. APPLICABLE DOCUMENTS
3. DEFINITIONS
4. GENERAL REQUIREMENTS
5. DETAILED REQUIREMENTS
6. NOTES
APPENDIX A - Standard Methods for Mounting Equipment
APPENDIX B - Switchboard Mounting
APPENDIX C - Battery Rack Mounting
APPENDIX D - Casualty Power
APPENDIX E - Shore Power

Describes standard installation methods for casualty power, shore power, electrical equipment, and switchboards.

DevelopmentNote
Supersedes DOD STD 2003/2. (09/2009)
DocumentType
Standard
Pages
137
PublisherName
US Military Specs/Standards/Handbooks
Status
Superseded
SupersededBy
Supersedes

This standard covers standard installation methods for casualty power, shore power, electrical equipment, and switchboards.

MIL-DTL-32529 Base Document:2015 POWER ELECTRONIC CONVERSION EQUIPMENT, NAVAL SHIPBOARD
MIL-DTL-24765 Revision B:2016 POWER SUPPLY, UNINTERRUPTIBLE, STATIC (NAVAL SHIPBOARD)
MIL-STD-2042-2 Revision C:2016 FIBER OPTIC CABLE TOPOLOGY INSTALLATION STANDARD METHODS FOR SURFACE SHIPS AND SUBMARINES (EQUIPMENT) (PART 2 OF 7 PARTS)
MIL-STD-2003 Revision A:2009 Electric Plant Installation Standard Methods for Surface Ships and Submarines

SAE AMSDTL23053/5A Insulation Sleeving, Electrical, Heat Shrinkable, Polyolefin, Flexible, Crosslinked
MIL C 24231/10 : D CONNECTORS, SINGLE CABLE, TYPE III, 14-, 24-, 30- OR 40-CONDUCTOR
ASTM F 1267 : 2015-12 SPECIFICATION FOR METAL, EXPANDED, STEEL
A-A-50614 Base Document:1993 Battery, Storage (Portable, Sealed, Maintenance-Free, Lead-Acid) 12 Volt, 100 Ampere-Hour, Type 12V-S-100 AH
SAE AMSQQA250/8C Aluminum Alloy 5052, Plate and Sheet
MIL-DTL-24441-20 Revision B:2009 Paint, Epoxy-Polyamide, Green Primer, Formula 150, Type III
MIL-PRF-32273-1 Revision A:2010 Battery Cells and Modules, Valve Regulated Lead-Acid, Main Storage, Submarine, Classification Type B
MIL-C-24368-4 Revision A:1987 Connector Assemblies; Plugs and Receptacles, Electric, Power Transfer, Shore to Ship and Ship to Ship, 500 Volts, 500 Amperes, 60 Hertz, Symbol Numbers 1162.1, 1162.2 and 1162.3
MIL-DTL-16036 Revision M:2013 SWITCHGEAR, POWER, LOW VOLTAGE, NAVAL SHIPBOARD
A-A-50617 Base Document:1993 Battery, Storage (Portable, Sealed, Maintenance-Free, Lead-Acid) 6 Volt, 200 Ampere-Hour, Type 6V-S-200 AH
MIL-HDBK-2036 Base Document:1999 Electronic Equipment Specifications, Preparation of
ASTM A 1008/A1008M : 2016-09 SPECIFICATION FOR STEEL, SHEET, COLD-ROLLED, CARBON, STRUCTURAL, HIGH-STRENGTH LOW-ALLOY, HIGH-STRENGTH LOW-ALLOY WITH IMPROVED FORMABILITY, SOLUTION HARDENED, AND BAKE HARDENABLE
MIL-PRF-32273 Revision A:2010 Battery Cells and Modules, Valve Regulated Lead-Acid, Main Storage, Submarine; General Specification for
NEMA HP 6 : 2013 ELECTRICAL AND ELECTRONIC SILICONE AND SILICONE BRAIDED INSULATED, HOOK-UP WIRE, TYPES S (600 V), ZHS (600 V), SS (1000 V), ZHSS (1000 V), AND SSB BRAIDED (1000 V)
SAE AMSDTL23053/4A Insulation Sleeving, Electrical, Heat Shrinkable, Polyolefin, Dual-Wall, Outer Wall Crosslinked
MIL E 917 : E ELECTRIC POWER EQUIPMENT, BASIC REQUIREMENTS (NAVAL SHIPBOARD USE)
MIL-C-24368-5 Base Document:1987 Connector Assemblies; Plug, Submarine Shore Power Transfer, Shore to Ship and Ship to Ship, 500 Volts, 400 Amperes, 60 Hertz, Three-Phase Symbol Number 1149
DOD-STD-2134 Base Document:1981 Storage Battery Arrangement for Minimum Stray Magnetic Field (Metric)
SAE AS81765/1A INSULATING COMPONENTS, MOLDED, ELECTRICAL, HEAT SHRINKABLE POLYOLEFIN, CROSSLINKED, SEMI-RIGID AND FLEXIBLE
MIL-DTL-24552 Revision B:2001 Terminals and Seals, Plugs and Switch, Casualty Power Systems, Receptacle Type,
MIL-DTL-24552-4 Revision B:2001 Terminals and Seals, Plugs and Switch, Casualty Power, Plug, 100-Ampere, 450-Volt, Alternating Current, Three-Phase, Symbol No. 1049
MIL C 24231/25 : D CONNECTOR, HULL INSERTS
A-A-50616 Base Document:1993 Battery, Storage, (Portable, Sealed, Maintenance-Free, Lead-Acid) 12 Volt, 130 Ampere-Hour, Type 12V-S-130 AH
A-A-50618 Base Document:1993 Battery, Storage (Portable, Sealed, Maintenance-Free, Lead-Acid) 6 Volt, 300 Ampere-Hour Type 6V-S-300 AH
NASM25027:2012 NUT, SELF-LOCKING, 250 DEGREES F, 450 DEGREES F, AND 800 DEGREES F
MIL C 24231/1 : D CONNECTOR, PLUG, MOLDED, THREE, FOUR, AND FIVE CONDUCTOR
MIL-DTL-24643-3 Revision E:2009 Cable, Electrical, -4 Degrees Fahrenheit (-20 Degrees Celsius) to +194 Degrees Fahrenheit (+90 Degrees Celsius), 600 Volts, Types LSSHOF, LSDHOF, LSTHOF, and LSFHOF
MIL-DTL-24441 Revision D:2009 Paint, Epoxy-Polyamide, General Specification for
MIL-I-24768-1 Base Document:1992 Insulation, Plastic, Laminated, Thermosetting, Glass-Cloth, Melamine-Resin (GME)
MIL-STD-2003-4 Revision A:2009 Electric Plant Installation Standard Methods for Surface Ships and Submarines (Cableways)
MIL-DTL-915-6 Revision K:2002 Cable, Power Electrical, 600 Volts, for Outboard Use only (not for Inboard Use), Type THOF
MIL-STD-1310 Revision H:2009 SHIPBOARD BONDING, GROUNDING, AND OTHER TECHNIQUES FOR ELECTROMAGNETIC COMPATIBILITY, ELECTROMAGNETIC PULSE (EMP) MITIGATION, AND SAFETY
NAVSEA S9074 AR GIB 010/278 : 0 REQUIREMENTS FOR FABRICATION WELDING AND INSPECTION, AND CASTING INSPECTION AND REPAIR FOR MACHINERY, PIPING, AND PRESSURE VESSELS
A-A-50611 Base Document:1993 Battery, Storage (Portable, Sealed, Maintenance-Free, Lead-Acid) 6 Volt, 50 Ampere-Hour, Type 6V-S-50 AH (No S/S Document)
MIL-W-21157 Revision A:1971 Weldment,Steel, Carbon and Low Alloy (Yield Strength 30,000-60,000 Psi
SAE AMSDTL23053/18A Insulation Sleeving, Electrical, Heat Shrinkable, Modified Fluoropolymer, Crosslinked
MM-L-736 Revision D:2008 Lumber; Hardwood
MIL C 24368/1 : B CONNECTOR ASSEMBLIES, PLUG, POWER TRANSFER, SHORE TO SHIP AND SHIP TO SHIP, 5OO VOLTS, 5OO AMPERES, 6O HERTZ, SYMBOL NUMBER 116O
A-A-50609 Base Document:1993 Battery, Storage (Portable, Sealed, Maintenance-Free, Lead-Acid) 12 Volt, 15 Ampere-Hour, Type 12V-S-15 AH
A-A-50615 Base Document:1993 Battery, Storage (Portable, Sealed, Maintenance-Free, Lead-Acid) 6 Volt, 130 Ampere-Hour, Type 6V-S-130 AH
MIL-DTL-5516 Revision D:2008 Packing, Preformed, Petroleum Hydraulic Fluid Resistant, 160 Degrees F (71 Degrees C)
MIL S 901 : D SHOCK TESTS, HI [HIGH IMPACT] SHIPBOARD MACHINERY, EQUIPMENT AND SYSTEMS, REQUIREMENTS FOR
ASTM B 209 : 2014 : REDLINE Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate
A-A-50612 Base Document:1993 Battery, Storage (Portable, Sealed, Maintenance-Free, Lead-Acid) 12 Volt, 50 Ampere-Hour, Type 12V-S-50 AH
A-A-59125 Revision B:2012 Terminal Boards, Molded, Barrier Screw and Stud Types and Associated Accessories
A-A-59296 Base Document:1998 Insulating Compound, Electrical (for Field Splicing Applications)
A-A-50610 Base Document:1993 Battery, Storage (Portable, Sealed, Maintenance-Free, Lead-Acid) 2 Volt, 20 Ampere-Hour, Type 2V-S-20 AH
FF-S-92 Revision C:2014 SCREW, MACHINE, SLOTTED, CROSS-RECESSED OR HEXAGON HEAD
MIL-DTL-24552-2 Revision B:2001 Terminals and Seals, Plugs and Switch, Casualty Power, Receptacle Type, Upper and Lower Riser, 200-Ampere, 450-Volt, Alternating Current, Three-Phase, Symbol No. 1047
SAE AMSDTL23053/15A Insulation Sleeving, Electrical, Heat Shrinkable, Polyolefin, Heavy-Wall, Coated, Flexible, Outer Wall Crosslinked
MIL-S-24149 Revision C:1989 Studs, Welding, and Arc Shields (Ferrules), General Specification for
MIL-STD-2003-3 Revision A:2009 Electric Plant Installation Standard Methods for Surface Ships and Submarines (Penetrations)
MIL-PRF-32273-2 Revision A:2010 Battery Cells and Modules, Valve Regulated Lead-Acid, Main Storage, Submarine, Classification Type C
MIL-STD-3007 Revision F:2006 Unified Facilities Criteria, Facilities Criteria and Unified Facilities Guide Specifications
MIL-C-24368-6 Base Document:1987 Connector Assemblies; Dual Purpose, Submarine Shore Power Transfer (AC) and DSRV Battery Charging (DC), 500 Volts, 400 Amperes, 60 Hertz, Three-Phase, Symbols 1150 and 1150.1
MIL-DTL-15024 Revision F:1997 Plates and Tags for Identification of Equipment, General Specification for
MIL-I-15265 Revision C:1992 Insulation, Electrical, Plastic (Submarine Bus Bar Covering) (No S/S Document)
FED-STD-H28 Revision A:1994 Screw-Thread Standards for Federal Services
MIL-DTL-24643-16 Revision F:2009 Cable, Electrical, -4 Degrees Fahrenheit (-20 Degrees Celsius) to +221 Degrees Fahrenheit (+105 Degrees Celsius), 1,000 Volts, Type LSTSGU
MIL-DTL-24552-1 Revision B:2001 Terminals and Seals, Plugs and Switch, Casualty Power, Receptacle Type, Back Connected 200 Ampere, 450-Volt, Alternating Current, Three-Phase, Symbol No. 1046
MIL-DTL-24552-3 Revision B:2001 Terminals and Seals, Plugs and Switch, Casualty Power, Seal, Symbol No. 1048
MIL-S-24235 Revision C:1992 Stuffing Tubes, Metal, and Packing Assemblies for Electric Cables, General Specification for
MIL C 24368/2 : B CONNECTOR ASSEMBLIES, RECEPTACLE, AND RECEPTACLE - CABLED, POWER TRANSFER, SHORE TO SHIP AND SHIP TO SHIP, 5OO VOLTS, 5OO AMPERES, 6O HERTZ, SYMBOL NUMBER 1161
A-A-50613 Base Document:1993 Battery, Storage (Portable, Sealed, Maintenance-Free, Lead-Acid) 6 Volt, 100 Ampere-Hour, Type 6V-S-100 AH
MIL-PRF-23236 Revision D:2009 Coating Systems for Ship Structures
MIL-STD-2003-1 Revision A:2009 Electric Plant Installation Standard Methods for Surface Ships and Submarines (Cable)

Access your standards online with a subscription

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

£15.19
Excluding VAT