MIL-PRF-83383 Revision F:2017
Current
The latest, up-to-date edition.
Circuit Breakers, Remote Control, Thermal, Trip Free General Specification For
English
27-06-2017
1. SCOPE
2. APPLICABLE DOCUMENTS
3. REQUIREMENTS
4. VERIFICATION
5. PACKAGING
6. NOTES
APPENDIX A - ELECTRONIC COMPONENTS
APPENDIX B - DC INDUCTOR CALIBRATION PROCESS
Specifies the general requirements and test procedures for single and triple pole, trip-free, thermal, remote control circuit breakers for use in electric systems conforming to MIL-STD-704.
| DevelopmentNote |
Supersedes MIL C 83383 (C). (04/2002)
|
| DocumentType |
Standard
|
| Pages |
40
|
| PublisherName |
US Military Specs/Standards/Handbooks
|
| Status |
Current
|
| Supersedes |
This specification covers the general requirements and test procedures for single and triple pole, trip-free, thermal, remote control circuit breakers for use in electric systems conforming to MIL-STD-704. These remote control circuit breakers are capable of being remotely set or tripped and provide indication of the main contact position by use of a 0.5 ampere, push-pull, trip-free circuit breaker (not covered by this specification). These remote control circuit breakers include auxiliary contacts (see 6.5.4) and terminals for control/monitor circuits. Hereinafter, a remote control circuit breaker is referred to as an RCCB (see 6.9).
| MIL-PRF-83383-4 Revision G:2017 | Circuit Breakers, Remote Control, AC-DC, Thermal, Trip-Free, Series Trip, Triple Pole, Auxiliary Contacts (5 to 100 Amperes) |
| MIL-PRF-83383-11 Base Document:2007 | Circuit Breakers, Remote Control, AC-DC, Thermal, Trip-Free, Series Trip, Single Pole, Auxiliary Contacts, Internal Wiring Connection for Multiple Line Protection (5 to 100 Amperes) (No S/S Document) |
| MIL-PRF-83383-10 Base Document:2007 | Circuit Breakers, Remote Control, AC-DC, Thermal, Trip-Free, Series Trip, Single Pole, Internal Wiring Connection for Multiple Line Protection (5 TO 100 Amperes) (No S/S Document) |
| MIL-PRF-83383-2 Revision G:2016 | Circuit Breakers, Remote Control, AC-DC, Thermal, Trip-Free, Series Trip, Single Pole, Auxiliary Contacts (5 to 100 Amperes) |
| MIL-PRF-83383-1 Revision G:2016 | Circuit Breakers, Remote Control, AC-DC, Thermal, Trip-Free, Series Trip, Single Pole, (5 to 100 Amperes) |
| MIL-STD-202-211 Base Document:2015 | Method 211, Terminal Strength |
| SAE AMS1424M | Deicing/Anti-Icing Fluid, Aircraft SAE Type 1 |
| MIL-STD-704 Revision F:2004 | Aircraft Electric Power Characteristics |
| MIL-STD-202-302 Base Document:2015 | Method 302, Insulation Resistance |
| MIL-DTL-5624 Revision W:2016 | Turbine Fuel, Aviation, Grades JP-5 (NATO F-44) |
| MIL-STD-883 Revision K:2016 | Microcircuits |
| MIL-STD-202-109 Base Document:2015 | Method 109, Explosion |
| MIL-PRF-7808 Revision L:1997 | Lubricating Oil, Aircraft Turbine Engine, Synthetic Base |
| ANSI/NCSL Z540 3 : 2006(R2013) | REQUIREMENTS FOR THE CALIBRATION OF MEASURING AND TEST EQUIPMENT |
| MIL-PRF-5606 Revision H:2002 | Hydraulic Fluid, Petroleum Base; Aircraft, Missile, and Ordnance |
| MIL-PRF-19500 Revision P:2010 | Semiconductor Devices, General Specification for |
| MIL-PRF-87937 Revision D:2001 | Cleaning Compound, Aerospace Equipment |
| MIL-STD-202-101 Base Document:2015 | Method 101, Salt Atmosphere (Corrosion) |
| MIL-STD-202-107 Base Document : 2015 | Method 107, Thermal Shock |
| MIL-HDBK-454 Revision B:2007 | General Guidelines for Electronic Equipment |
| MIL-STD-202-106 Base Document:2015 | Method 106, Moisture Resistance |
| MIL-STD-202-301 Base Document:2015 | Method 301, Dielectric Withstanding Voltage |
| MIL-STD-202-215 Base Document:2015 | Method 215, Resistance to Solvents |
| MIL-PRF-23699 Revision G:2014 | Lubricating Oil, Aircraft Turbine Engine, Synthetic Base, NATO Code Numbers: O-152, O-154, O-156, and O-167 |
| SAE AS81714B | Terminal Junction System (TJS), Environment Resistant General Specification For |
| MIL-STD-461 Revision G:2015 | Requirements for the Control of Electromagnetic Interference Characteristics of Subsystems and Equipment |
| MIL-PRF-83383-4 Revision G:2017 | Circuit Breakers, Remote Control, AC-DC, Thermal, Trip-Free, Series Trip, Triple Pole, Auxiliary Contacts (5 to 100 Amperes) |
| MIL-PRF-83383-1 Revision G:2016 | Circuit Breakers, Remote Control, AC-DC, Thermal, Trip-Free, Series Trip, Single Pole, (5 to 100 Amperes) |
| SAE AS39029/1C | CONTACTS, ELECTRICAL CONNECTOR, PIN, CRIMP REMOVABLE (FOR AS81714 TERMINAL JUNCTION SYSTEM) |
| SAE AS1241D | Fire Resistant Phosphate Ester Hydraulic Fluid for Aircraft |
| MIL-PRF-83282 Revision D:1997 | Hydraulic Fluid, Fire Resistant, Synthetic Hydrocarbon Base, Metric, NATO Code Number H-537 |
| MIL-STD-202-310 Base Document:2015 | Method 310, Contact-Chatter Monitoring |
| MIL-STD-202-110 Base Document:2015 | Method 110, Sand and Dust |
| MIL-PRF-38535 Revision K:2013 | Integrated Circuits (Microcircuits) Manufacturing, General Specification for |
| MIL-STD-202 Revision H:2015 | Electronic and Electrical Component Parts |
| MIL-STD-1285 Revision D:2004 | Marking of Electrical and Electronic Parts |
| FED-STD-H28 Revision A:1994 | Screw-Thread Standards for Federal Services |
| ISO 10012-1:1992 | Quality assurance requirements for measuring equipment — Part 1: Metrological confirmation system for measuring equipment |
| MIL-STD-202-204 Base Document:2015 | Method 204, Vibration, High Frequency |
| MIL-PRF-83383-2 Revision G:2016 | Circuit Breakers, Remote Control, AC-DC, Thermal, Trip-Free, Series Trip, Single Pole, Auxiliary Contacts (5 to 100 Amperes) |
| MIL-STD-202-213 Base Document:2015 | Method 213, Shock (Specified Pulse) |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.