MIL-PRF-39007 Revision J:2005
Current
The latest, up-to-date edition.
Resistor, Fixed, Wirewound, (Power Type) Nonestablished Reliability, Established Reliability, and Space Level General Specification for
17-06-2005
1. SCOPE
2. APPLICABLE DOCUMENTS
3. REQUIREMENTS
4. VERIFICATION
5. PACKAGING
6. NOTES
APPENDIX A - PROCEDURE FOR QUALIFICATION INSPECTION
APPENDIX B - PROCEDURES FOR DESTRUCTIVE PHYSICAL
ANALYSIS (DPA) (SPACE LEVEL ONLY)
APPENDIX C - RADIOGRAPHIC INSPECTION (SPACE
LEVEL ONLY)
Specifies the general requirements for nonestablished reliability (non-ER), established reliability (ER), or space level, axial lead precision, power type, wire wound, fixed resistors having a +25 degrees C ambient operating temperature derated to zero load at +250 degrees C for use in electrical, electronic communication, and associated equipment.
DevelopmentNote |
Supersedes MIL R 39007 (G). (08/2005)
|
DocumentType |
Standard
|
Pages |
196
|
PublisherName |
US Military Specs/Standards/Handbooks
|
Status |
Current
|
Supersedes |
This specification covers the general requirements for nonestablished reliability (non-ER), established reliability (ER), or space level, axial lead precision, power type, wirewound, fixed resistors having a +25OC ambient operating temperature derated to zero load at +250OC for use in electrical, electronic communication, and associated equipment. These resistors have initial resistance tolerances of ±0.5 percent, ±0.1 percent, and ±1.0 percent, and a resistance temperature characteristic as given in table I. ER resistors covered by this specification will have failure rates (FR) ranging from 1 percent to 0.001 percent per 1,000 hours (see 1.2.1.5). These FR are established at 60 percent confidence on the basis of life tests (permissible resistance change of 1.0 percent). Resistors which are noninductively wound with solderable terminals are designated by a terminal designated \"N\" and \"Z\". Terminals designated by the letters \"S\" and \"W\" are inductively wound with solderable and weldable terminals (see 1.2.1.2).
MIL-PRF-39007-11 Revision J:2008 | RESISTOR, FIXED, WIREWOUND (POWER TYPE), NONESTABLISHED RELIABILITY, ESTABLISHED RELIABILITY, AND SPACE LEVEL STYLE RWR89 |
MIL-STD-1580 Revision B:2003 | DESTRUCTIVE PHYSICAL ANALYSIS FOR ELECTRONIC, ELECTROMAGNETIC, AND ELECTROMECHANICAL PARTS |
DSCC 10006 : A | RESISTOR, CURRENT SENSE, OPEN AIR, STANDARD LEADS, 1 WATT |
DSCC 10007 : A | RESISTOR, CURRENT SENSE, OPEN AIR, STANDARD LEADS, 3 WATT |
MIL STD 11991 : A | GENERAL STANDARD FOR PARTS, MATERIALS, AND PROCESSES |
MIL-PRF-39007-5 Revision J:2008 | RESISTOR, FIXED, WIREWOUND (POWER TYPE), NONESTABLISHED RELIABILITY, ESTABLISHED RELIABILITY, AND SPACE LEVEL STYLE RWR71 |
MIL-PRF-39007-7 Revision H:2008 | RESISTOR, FIXED, WIREWOUND (POWER TYPE), NONESTABLISHED RELIABILITY, ESTABLISHED RELIABILITY, AND SPACE LEVEL STYLE RWR78 |
MIL-HDBK-199 Revision D:2018 | Resistors, Selection and Use of |
MIL-DTL-39032 Revision E:2000 | RESISTORS, PACKAGING OF |
DSCC 10010 : A | RESISTOR, CURRENT SENSE, OPEN AIR, METAL ALLOY STRIP, 5 WATTS |
DSCC 10008 : A | RESISTOR, CURRENT SENSE, OPEN AIR, STANDARD LEADS, 5 WATT |
MIL-PRF-26 Revision H:2006 | RESISTOR, FIXED, WIREWOUND (POWER TYPE), GENERAL SPECIFICATION FOR |
DSCC 89040 : D | RESISTOR, FIXED, WIRE WOUND, SURFACE MOUNT, POWER TYPE (2.5 WATTS) |
NASA MSFC STD 3012 : 2012 | ELECTRICAL, ELECTRONIC, AND ELECTROMECHANICAL (EEE) PARTS MANAGEMENT AND CONTROL REQUIREMENTS FOR MSFC SPACE FLIGHT HARDWARE |
MIL-PRF-39007-6 Revision H:2008 | RESISTOR, FIXED, WIRE-WOUND (POWER TYPE), NONESTABLISHED RELIABILITY, ESTABLISHED RELIABILITY, AND SPACE LEVEL STYLE RWR74 |
DSCC 93075 : F | RESISTOR, FIXED, WIREWOUND, SURFACE MOUNT, POWER TYPE (1/2 WATT) |
MIL-PRF-39007-10 Revision H:2008 | RESISTOR, FIXED, WIREWOUND (POWER TYPE), NONESTABLISHED RELIABILITY, ESTABLISHED RELIABILITY, AND SPACE LEVEL STYLE RWR84 |
MIL-PRF-39007-12 Revision F:2008 | RESISTOR, FIXED, WIREWOUND (POWER TYPE), NONESTABLISHED RELIABILITY, ESTABLISHED RELIABILITY, AND SPACE LEVEL STYLE RWR82 |
DSCC 93076 : J | RESISTOR, FIXED, WIREWOUND, SURFACE MOUNT, POWER TYPE (1 WATT) |
DSCC 07002 : C | RESISTOR, FIXED, WIREWOUND, SURFACE MOUNT, POWER TYPE (3 WATT) |
DSCC 93077 : G | RESISTOR, FIXED, WIREWOUND, SURFACE MOUNT, POWER TYPE (2 WATT) |
MIL-PRF-39007-9 Revision J:2008 | RESISTOR, FIXED, WIREWOUND (POWER TYPE), NONESTABLISHED RELIABILITY, ESTABLISHED RELIABILITY, AND SPACE LEVEL STYLE RWR81 |
MIL-STD-202-211 Base Document:2015 | METHOD 211, TERMINAL STRENGTH |
MIL-STD-202-302 Base Document:2015 | Method 302, Insulation Resistance |
MIL-STD-202-304 Base Document:2015 | Method 304, Resistance-Temperature Characteristic |
MIL-STD-810 Revision G:2008 | ENVIRONMENTAL ENGINEERING CONSIDERATIONS AND LABORATORY TESTS |
MIL-STD-1276 Revision H:2013 | Leads for Electronic Component Parts |
MIL-STD-202-303 Base Document:2015 | Method 303, DC Resistance |
ASTM E 595 : 2015 : REDLINE | Standard Test Method for Total Mass Loss and Collected Volatile Condensable Materials from Outgassing in a Vacuum Environment |
MIL-STD-202-107 Base Document:2015 | Method 107, Thermal Shock |
MIL-STD-202-106 Base Document:2015 | Method 106, Moisture Resistance |
MIL-STD-202-301 Base Document:2015 | Method 301, Dielectric Withstanding Voltage |
MIL-STD-202-215 Base Document:2015 | METHOD 215, RESISTANCE TO SOLVENTS |
MIL-STD-790 Revision G:2011 | ESTABLISHED RELIABILITY AND HIGH RELIABILITY QUALIFIED PRODUCTS LIST (QPL) SYSTEMS FOR ELECTRICAL, ELECTRONIC, AND FIBER OPTIC PARTS SPECIFICATIONS |
MIL-STD-202-108 Base Document:2015 | Method 108, Life (at Elevated Ambient Temperature) |
MIL-STD-202-105 Base Document:2015 | Method 105, Barometric Pressure (Reduced) |
MIL-STD-202-208 Base Document:2015 | Method 208, Solderability |
MIL-STD-202 Revision H:2015 | ELECTRONIC AND ELECTRICAL COMPONENT PARTS |
MIL-STD-1285 Revision D:2004 | MARKING OF ELECTRICAL AND ELECTRONIC PARTS |
EIA 557 : 2006 | STATISTICAL PROCESS CONTROL SYSTEMS |
MIL-STD-690 Revision D:2005 | Failure Rate (FR) Sampling Plans and Procedures |
MIL-STD-202-204 Base Document:2015 | Method 204, Vibration, High Frequency |
MIL-STD-202-213 Base Document:2015 | Method 213, Shock (Specified Pulse) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.