ISO/IEC 14763-3:2014
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Information technology — Implementation and operation of customer premises cabling — Part 3: Testing of optical fibre cabling
Hardcopy , PDF
08-07-2014
24-05-2024
ISO/IEC 14763-3:2014(E) specifies systems and methods for the inspection and testing of installed optical fibre cabling designed in accordance with premises cabling standards including ISO/IEC 11801, ISO/IEC 24764, ISO/IEC 24702 and ISO/IEC 15018. The test methods refer to existing standards-based procedures where they exist. This second edition cancels and replaces the first edition published in 2006 and its Amendment 1:2009. It constitutes a technical revision. This edition includes the following changes:- general requirements have been revised; - OTDR characterization (6.2) and requirements for cabling interface adapters and test cords have been revised; - enhanced three-test-cord reference method has been introduced; - information on optical time domain reflectometry (Annex C) has been revised; - examples of calculations of channel and permanent link limits (Annex G) have been revised and information regarding cleaning and inspection of fibre optic connections have been added (Annex H).
| Committee |
ISO/IEC JTC 1/SC 25
|
| DevelopmentNote |
Supersedes ISO/IEC TR 14763-3. (06/2006)
|
| DocumentType |
Standard
|
| Pages |
51
|
| PublisherName |
International Organization for Standardization
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
| Standards | Relationship |
| DIN ISO/IEC 14763-3 : 2014 | Identical |
| VDE 0800-763-3 : 2014 | Identical |
| NEN ISO/IEC 14763-3 : 2014 C1 2015 | Identical |
| CAN/CSA-ISO/IEC 14763-3:15 (R2020) | Identical |
| JIS X 5151:2018 | Identical |
| DS ISO/IEC 14763-3 : 2014 COR 1 2015 | Identical |
| BS ISO/IEC 14763-3 : 2006 | Identical |
| PN ISO/IEC 14763-3 : 2009 AMD 1 2010 | Identical |
| CSA ISO/IEC 14763-3A : 2010(R2012) | Identical |
| 12/30268386 DC : 0 | BS EN 50700 - INFORMATION TECHNOLOGY - PREMISES DISTRIBUTION ACCESS NETWORK (PDAN) CABLING TO SUPPORT DEPLOYMENT OF OPTICAL BROADBAND NETWORKS |
| BS ISO/IEC 11801-1:2017 | Information technology. Generic cabling for customer premises General requirements |
| PREN 50700 : DRAFT 2012 | INFORMATION TECHNOLOGY - PREMISES DISTRIBUTION ACCESS NETWORK (PDAN) CABLING TO SUPPORT DEPLOYMENT OF OPTICAL BROADBAND NETWORKS |
| 16/30325966 DC : 0 | BS ISO/IEC 11801-6 - INFORMATION TECHNOLOGY - GENERIC CABLING FOR CUSTOMER PREMISES - PART 6: DISTRIBUTED BUILDING SERVICES |
| 09/30211785 DC : 0 | BS ISO/IEC 14763-2 - INFORMATION TECHNOLOGY - IMPLEMENTATION AND OPERATION OF CUSTOMER PREMISES CABLING - PART 2: PLANNING AND INSTALLATION |
| BS EN 61280-4-1:2009 | Fibre optic communication subsystem test procedures Installed cable plant. Multimode attenuation measurement |
| BS ISO/IEC 11801-5:2017 | Information technology. Generic cabling for customer premises Data centres |
| ISO/IEC 11801-2:2017 | Information technology — Generic cabling for customer premises — Part 2: Office premises |
| I.S. EN 61280-4-2:2014 | FIBRE-OPTIC COMMUNICATION SUBSYSTEM TEST PROCEDURES - PART 4-2: INSTALLED CABLE PLANT - SINGLE-MODE ATTENUATION AND OPTICAL RETURN LOSS MEASUREMENT |
| PD IEC/TR 61282-14:2016 | Fibre optic communication system design guides Determination of the uncertainties of attenuation measurements in fibre plants |
| ISO/IEC 11801-4:2017 | Information technology — Generic cabling for customer premises — Part 4: Single-tenant homes |
| ISO/IEC 14763-2:2012 | Information technology — Implementation and operation of customer premises cabling — Part 2: Planning and installation |
| I.S. EN 50346:2003 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - TESTING OF INSTALLED CABLING |
| ISO/IEC 24702:2006 | Information technology — Generic cabling — Industrial premises |
| ISO/IEC 14543-3-4:2007 | Information technology — Home electronic system (HES) architecture — Part 3-4: System management — Management procedures for network based control of HES Class 1 |
| ISO/IEC 14543-3-6:2007 | Information technology — Home electronic system (HES) architecture — Part 3-6: Media and media dependent layers — Network based on HES Class 1, twisted pair |
| EN 61280-4-2:2014 | Fibre-optic communication subsystem test procedures - Part 4-2: Installed cable plant - Single-mode attenuation and optical return loss measurement |
| EN 61280-4-1:2009 | Fibre optic communication subsystem test procedures - Part 4-1: Installed cable plant - Multimode attenuation measurement |
| EN 50700:2014 | Information technology - Premises distribution access network (PDAN) cabling to support deployment of optical broadband networks |
| EN 50346 : 2002 AMD 2 2009 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - TESTING OF INSTALLED CABLING |
| BS EN 61280-4-2:2014 | Fibre-optic communication subsystem test procedures Installed cable plant. Single-mode attenuation and optical return loss measurement |
| 16/30325955 DC : 0 | BS ISO/IEC 11801-5 - INFORMATION TECHNOLOGY - GENERIC CABLING FOR CUSTOMER PREMISES - PART 5: DATA CENTRES |
| BS EN 50346 : 2002 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - TESTING OF INSTALLED CABLING |
| ISO/IEC 11801-1:2017 | Information technology — Generic cabling for customer premises — Part 1: General requirements |
| IEC TR 61282-11:2012 | Fibre optic communication system design guides - Part 11: Multimode launch conditions |
| BS PD ISO/IEC TR 29106 : 2007 | INFORMATION TECHNOLOGY - GENERIC CABLING - INTRODUCTION TO THE MICE ENVIRONMENTAL CLASSIFICATION |
| BS EN 50174-1 : 2009 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 1: INSTALLATION SPECIFICATION AND QUALITY ASSURANCE |
| IEC TR 62614-2:2015 | Fibre optics - Multimode launch conditions - Part 2: Determination of launch condition requirements for measuring multimode attenuation |
| IEC 61280-4-1:2009 | Fibre-optic communication subsystem test procedures - Part 4-1: Installed cable plant - Multimode attenuation measurement |
| I.S. EN 61918:2013 | INDUSTRIAL COMMUNICATION NETWORKS - INSTALLATION OF COMMUNICATION NETWORKS IN INDUSTRIAL PREMISES |
| 16/30325974 DC : 0 | BS ISO/IEC 11801-2 - INFORMATION TECHNOLOGY - GENERIC CABLING FOR CUSTOMER PREMISES - PART 2: OFFICE PREMISES |
| 16/30325952 DC : 0 | BS ISO/IEC 11801-4 - INFORMATION TECHNOLOGY - GENERIC CABLING FOR CUSTOMER PREMISES - PART 4: HOMES |
| BS ISO/IEC 11801-2:2017 | Information technology. Generic cabling for customer premises Office premises |
| CEI EN 61280-4-1 : 2011 | FIBRE OPTIC COMMUNICATION SUBSYSTEM TEST PROCEDURES - PART 4-1: INSTALLED CABLE PLANT - MULTIMODE ATTENUATION MEASUREMENT |
| BS IEC/IEEE 62582-5:2015 | Nuclear power plants. Instrumentation and control important to safety. Electrical equipment condition monitoring methods Optical time domain reflectometry |
| ISO/IEC 11801-6:2017 | Information technology — Generic cabling for customer premises — Part 6: Distributed building services |
| CEI EN 61280-4-2 : 2015 | FIBRE-OPTIC COMMUNICATION SUBSYSTEM TEST PROCEDURES - PART 4-2: INSTALLED CABLE PLANT - SINGLE-MODE ATTENUATION AND OPTICAL RETURN LOSS MEASUREMENT |
| ISO/IEC 14762:2009 | Information technology — Functional safety requirements for Home and Building Electronic Systems (HBES) |
| I.S. EN 50174-1:2009 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 1: INSTALLATION SPECIFICATION AND QUALITY ASSURANCE |
| ISO/IEC 30129:2015 | Information technology — Telecommunications bonding networks for buildings and other structures |
| ISO/IEC 14543-3-7:2007 | Information technology — Home electronic system (HES) architecture — Part 3-7: Media and media dependent layers — Radio frequency for network based control of HES Class 1 |
| ISO/IEC 14543-3-5:2007 | Information technology — Home electronic system (HES) architecture — Part 3-5: Media and media dependent layers — Power line for network based control of HES Class 1 |
| IEC 61918:2013 | Industrial communication networks - Installation of communication networks in industrial premises |
| BS EN 61918:2013 | Industrial communication networks. Installation of communication networks in industrial premises |
| 10/30240050 DC : DRAFT DEC 2010 | BS EN 61280-4-2 - FIBRE-OPTIC COMMUNICATION SUBSYSTEM TEST PROCEDURES - PART 4-2: INSTALLED CABLE PLANT - SINGLEMODE ATTENUATION AND OPTICAL RETURN LOSS MEASUREMENT |
| 11/30244353 DC : 0 | BS EN 61753-123-2 - FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - PERFORMANCE STANDARD - PART 123-2: SIMPLEX AND DUPLEX REFERENCE CORDS WITH SINGLE-MODE FIBRE AND CYLINDRICAL FERRULE CONNECTORS |
| PD IEC/TR 61282-11:2012 | Fibre optic communication system design guides Multimode launch conditions |
| 15/30326655 DC : 0 | BS EN 61280-4-1 - FIBRE-OPTIC COMMUNICATION SUBSYSTEM TEST PROCEDURES - PART 4-1: INSTALLED CABLE PLANT - MULTIMODE ATTENUATION MEASUREMENT |
| 09/30211750 DC : 0 | BS EN 50174-1:200/PRA1:2 - INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 1: INSTALLATION SPECIFICATION AND QUALITY ASSURANCE |
| BS EN 50700:2014 | Information technology. Premises distribution access network (PDAN) cabling to support deployment of optical broadband networks |
| 16/30325949 DC : 0 | BS ISO/IEC 11801-3 - INFORMATION TECHNOLOGY - GENERIC CABLING FOR CUSTOMER PREMISES - PART 3: INDUSTRIAL PREMISES |
| 16/30325971 DC : 0 | BS ISO/IEC 11801-1 - INFORMATION TECHNOLOGY - GENERIC CABLING FOR CUSTOMER PREMISES - PART 1: GENERAL REQUIREMENTS |
| ISO/IEC 11801-5:2017 | Information technology — Generic cabling for customer premises — Part 5: Data centres |
| UFC 3-580-01 : Change 1 | UNIFIED FACILITIES CRITERIA - TELECOMMUNICATIONS INTERIOR INFRASTRUCTURE PLANNING AND DESIGN |
| IEEE 802.3-2012 | IEEE Standard for Ethernet |
| ISO/IEC 14543-3-3:2007 | Information technology — Home electronic system (HES) architecture — Part 3-3: User process for network based control of HES Class 1 |
| ISO/IEC TR 29106:2007 | Information technology — Generic cabling — Introduction to the MICE environmental classification |
| EN 50174-1:2009/A2:2014 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 1: INSTALLATION SPECIFICATION AND QUALITY ASSURANCE |
| IEC 61280-4-2:2014 | Fibre-optic communication subsystem test procedures - Part 4-2: Installed cable plant - Single-mode attenuation and optical return loss measurement |
| BS ISO/IEC 30129 : 2015 | INFORMATION TECHNOLOGY - TELECOMMUNICATIONS BONDING NETWORKS FOR BUILDINGS AND OTHER STRUCTURES |
| 11/30247511 DC : 0 | BS EN 61753-124-2 - FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - PART 124-2: SIMPLEX AND DUPLEX REFERENCE CORDS WITH MULTIMODE FIBRE AND CYLINDRICAL FERRULE CONNECTORS FOR CATEGORY C - CONTROLLED ENVIRONMENT |
| 14/30189466 DC : 0 | BS IEC/IEEE 62582-5 ED 1.0 - NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL IMPORTANT TO SAFETY - ELECTRICAL EQUIPMENT CONDITION MONITORING METHODS - PART 5: OPTICAL TIME DOMAIN REFLECTOMETRY |
| ISO/IEC 11801-3:2017 | Information technology — Generic cabling for customer premises — Part 3: Industrial premises |
| I.S. EN 61280-4-1:2009 | FIBRE OPTIC COMMUNICATION SUBSYSTEM TEST PROCEDURES - PART 4-1: INSTALLED CABLE PLANT - MULTIMODE ATTENUATION MEASUREMENT |
| I.S. EN 50700:2014 | INFORMATION TECHNOLOGY - PREMISES DISTRIBUTION ACCESS NETWORK (PDAN) CABLING TO SUPPORT DEPLOYMENT OF OPTICAL BROADBAND NETWORKS |
| EN 61918:2013/AC:2014 | INDUSTRIAL COMMUNICATION NETWORKS - INSTALLATION OF COMMUNICATION NETWORKS IN INDUSTRIAL PREMISES (IEC 61918:2013, MODIFIED) |
| 11/30258071 DC : 0 | BS EN 61918 - INDUSTRIAL COMMUNICATION NETWORKS - INSTALLATION OF COMMUNICATION NETWORKS IN INDUSTRIAL PREMISES |
| CEI EN 61918 : 2014 | INDUSTRIAL COMMUNICATION NETWORKS - INSTALLATION OF COMMUNICATION NETWORKS IN INDUSTRIAL PREMISES |
| ISO/IEC 14763-2:2012 | Information technology — Implementation and operation of customer premises cabling — Part 2: Planning and installation |
| IEC 60825-2:2004+AMD1:2006+AMD2:2010 CSV | Safety of laser products - Part 2: Safety of optical fibre communication systems (OFCS) |
| ISO/IEC 15018:2004 | Information technology — Generic cabling for homes |
| IEC 60050-731:1991 | International Electrotechnical Vocabulary (IEV) - Part 731: Optical fibre communication |
| IEC 61280-1-3:2010 | Fibre optic communication subsystem test procedures - Part 1-3: General communication subsystems - Central wavelength and spectral width measurement |
| IEC 60793-2-10:2017 | Optical fibres - Part 2-10: Product specifications - Sectional specification for category A1 multimode fibres |
| ISO/IEC 24702:2006 | Information technology — Generic cabling — Industrial premises |
| AS 11801.6:2019 | Information technology - Generic cabling for customer premises Distributed building services (ISO/IEC 11801-6:2017, MOD) |
| ISO/IEC 11801:2002 | Information technology — Generic cabling for customer premises |
| IEC 60793-2-40:2015 | Optical fibres - Part 2-40: Product specifications - Sectional specification for category A4 multimode fibres |
| IEC 62664-1-1:2013 | Fibre optic interconnecting devices and passive components - Fibre optic connector product specifications - Part 1-1: LC-PC duplex multimode connectors terminated on IEC 60793-2-10 category A1a fibre |
| IEC 61746-1:2009 | Calibration of optical time-domain reflectometers (OTDR) - Part 1: OTDR for single mode fibres |
| IEC TR 62627-01:2016 | Fibre optic interconnecting devices and passive components - Part 01: Fibre optic connector cleaning methods |
| IEC 60874-19-1:2007 | Fibre optic interconnecting devices and passive components - Connectors for optical fibres and cables - Part 19-1: Fibre optic patch cord connector type SC-PC (floating duplex) standard terminated on multimode fibre type A1a, A1b - Detail specification |
| IEC 61935-3:2008 | Testing of balanced and coaxial information technology cabling - Part 3: Installed cabling as specified in ISO/IEC 15018 and related standards |
| ISO/IEC 14763-1:1999 | Information technology — Implementation and operation of customer premises cabling — Part 1: Administration |
| AS 11801.3:2019 | Information technology - Generic cabling for customer premises Industrial premises (ISO/IEC 11801-3:2017, MOD) |
| IEC 60874-14-3:1997 | Connectors for optical fibres and cables - Part 14-3: Detail specification for fibre optic adaptor (simplex) type SC for single-mode fibre |
| IEC 60874-1:2011 | Fibre optic interconnecting devices and passive components - Connectors for optical fibres and cables - Part 1: Generic specification |
| IEC 61280-4-1:2009 | Fibre-optic communication subsystem test procedures - Part 4-1: Installed cable plant - Multimode attenuation measurement |
| IEC 61280-4-2:2014 | Fibre-optic communication subsystem test procedures - Part 4-2: Installed cable plant - Single-mode attenuation and optical return loss measurement |
| AS 11801.2:2019 | Information technology - Generic cabling for customer premises Office premises (ISO/IEC 11801-2:2017, MOD) |
| IEC 61300-3-6:2008 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-6: Examinations and measurements - Return loss |
| IEC 61300-3-35:2015 RLV | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-35: Examinations and measurements - Visual inspection of fibre optic connectors and fibre-stub transceivers |
| IEC 61300-3-4:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-4: Examinations and measurements - Attenuation |
| IEC 61935-1:2015 | Specification for the testing of balanced and coaxial information technology cabling - Part 1: Installed balanced cabling as specified in ISO/IEC 11801 and related standards |
| IEC 61746-2:2010 | Calibration of optical time-domain reflectometers (OTDR) - Part 2: OTDR for multimode fibres |
| IEC 60793-2-50:2015 | Optical fibres - Part 2-50: Product specifications - Sectional specification for class B single-mode fibres |
| IEC 61755-3-2:2006 | Fibre optic connector optical interfaces - Part 3-2: Optical interface, 2,5 mm and 1,25 mm diameter cylindrical full zirconia ferrules for 8 degrees angled-PC single mode fibres |
| IEC 61315:2005 | Calibration of fibre-optic power meters |
| ISO/IEC 24764:2010 | Information technology — Generic cabling systems for data centres |
| IEC 62614:2010 | Fibre optics - Launch condition requirements for measuring multimode attenuation |
| IEC 61755-3-1:2006 | Fibre optic connector optical interfaces - Part 3-1: Optical interface, 2,5 mm and 1,25 mm diameter cylindrical full zirconia PC ferrule, single mode fibre |
| IEC 61300-3-42:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-42: Examinations and measurements - Attenuation of single mode alignment sleeves and or adaptors with resilient alignment sleeves |
| IEC 61280-1-4:2009 | Fibre optic communication subsystem test procedures - Part 1-4: General communication subsystems - Light source encircled flux measurement method |
| IEC TR 61282-11:2012 | Fibre optic communication system design guides - Part 11: Multimode launch conditions |
| IEC 61745:2017 | End-face image analysis procedure for the calibration of optical fibre geometry test sets |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.