ISO 80601-2-13:2011
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Medical electrical equipment Part 2-13: Particular requirements for basic safety and essential performance of an anaesthetic workstation
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
29-04-2022
08-08-2011
ISO/IEC 80601-2-13:2011 is applicable to the basic safety and essential performance of an anaesthetic workstation for administering inhalational anaesthesia whilst continuously attended by a professional operator.
ISO/IEC 80601-2-13:2011 specifies particular requirements for a complete anaesthetic workstation and the following anaesthetic workstation components which, although considered as individual devices in their own right, may be utilized, in conjunction with other relevant anaesthetic workstation components, to form an anaesthetic workstation to a given specification:
- anaesthetic gas delivery system;
- anaesthetic breathing system;
- anaesthetic gas scavenging system;
- anaesthetic vapour delivery system;
- anaesthetic ventilator;
- monitoring equipment;
- alarm system;
- protection device.
ISO/IEC 80601-2-13:2011 is also applicable to those accessories intended by their manufacturer to be connected to an anaesthetic workstation where the characteristics of those accessories can affect the basic safety and essential performance of the anaesthetic workstation.
If a clause or subclause is specifically intended to be applicable to anaesthetic workstation components only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to an anaesthetic workstation and its individual components, as relevant.
Hazards inherent in the intended physiological function of an anaesthetic workstation and its individual components within the scope of ISO/IEC 80601-2-13:2011 are not covered by specific requirements in ISO/IEC 80601-2-13:2011 except in 7.2.13 and 8.4.1 of IEC 60601-1:2005.
ISO/IEC 80601-2-13:2011 is not applicable to any anaesthetic workstation intended for use with flammable anaesthetic agents, as determined by Annex BB.
DevelopmentNote |
Supersedes ISO/DIS 80601-2-13, ISO 8835-2, ISO 8835-3, ISO 8835-4 and ISO 8835-5. (08/2011) Supersedes IEC 60601-2-13. (04/2016)
|
DocumentType |
Standard
|
Pages |
99
|
ProductNote |
THIS STANDARD ALSO REFERS TO IEC 61010.
|
PublisherName |
International Organization for Standardization
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
Standards | Relationship |
IS/ISO 80601 : Part 2 : Sec 13 : 2011 | Identical |
ONORM EN ISO 80601-2-13 : 2013 | Identical |
GOST R ISO 80601-2-13 : 2013 | Identical |
NF EN ISO 80601-2-13 : 2013 AMD 1 2016 | Identical |
NBN EN ISO 80601-2-13 : 2013 | Identical |
NEN EN ISO 80601-2-13 : 2012 | Identical |
NS EN ISO 80601-2-13 : 2012 | Identical |
I.S. EN ISO 80601-2-13:2012 | Identical |
PN EN ISO 80601-2-13 : 2013 | Identical |
SN EN ISO 80601-2-13:2013 | Identical |
UNI EN ISO 80601-2-13 : 2013 | Identical |
VDE 0750-2-13 : 2013 | Identical |
DIN EN ISO 80601-2-13:2013 | Identical |
NF EN ISO 80601-2-13:2013 | Identical |
SS-EN ISO 80601-2-13: 2012 | Identical |
UNI EN ISO 80601-2-13:2020 | Identical |
UNE-EN ISO 80601-2-13:2013 | Identical |
BS EN ISO 80601-2-13:2012 | Identical |
EN ISO 80601-2-13:2012 | Identical |
ISO 5359:2014 | Anaesthetic and respiratory equipment — Low-pressure hose assemblies for use with medical gases |
09/30203808 DC : 0 | BS EN ISO 80601-2-12 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-12: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF CRITICAL CARE VENTILATORS |
CAN/CSA-C22.2 NO. 80601-2-72:17 | Medical electrical equipment — Part 2-72: Particular requirements for basic safety and essential performance of home healthcare environment ventilators for ventilator-dependent patients (Adopted ISO 80601-2-72:2015, first edition, 2015-09-01, with Canadian deviations) |
IEC 80601-2-49:2018 | Medical electrical equipment - Part 2-49: Particular requirements for the basic safety and essential performance of multifunction patient monitors |
I.S. EN 16844:2017+A2:2019 | Aesthetic medicine services - Non-surgical medical treatments |
BS EN ISO 80601-2-12:2011 | Medical electrical equipment Particular requirements for basic safety and essential performance of critical care ventilators |
17/30338753 DC : 0 | BS ISO 80601-2-79 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-79: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF VENTILATORY SUPPORT EQUIPMENT FOR VENTILATORY IMPAIRMENT |
BS EN ISO 80601-2-72:2015 | Medical electrical equipment Particular requirements for basic safety and essential performance of home healthcare environment ventilators for ventilator-dependent patients |
PD IEC/TR 60601-4-1:2017 | Medical electrical equipment Guidance and interpretation. Medical electrical equipment and medical electrical systems employing a degree of autonomy |
UNI EN ISO 5367 : 2015 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - BREATHING SETS AND CONNECTORS |
DIN EN ISO 80601-2-72:2016-04 | Medical electrical equipment - Part 2-72: Particular requirements for basic safety and essential performance of home healthcare environment ventilators for ventilator-dependent patients (ISO 80601-2-72:2015) |
13/30278952 DC : 0 | BS EN 16372 - AESTHETIC SURGERY AND AESTHETIC NON-SURGICAL MEDICAL SERVICES |
I.S. EN 16844:2017 | AESTHETIC MEDICINE SERVICES - NON-SURGICAL MEDICAL PROCEDURES |
AAMI ISO 5367 : 2015 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - BREATHING SETS AND CONNECTORS |
UNI EN ISO 80601-2-55 : 2012 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-55: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF RESPIRATORY GAS MONITORS |
BS EN ISO 5367:2014 | Anaesthetic and respiratory equipment. Breathing sets and connectors |
UNE-EN ISO 5367:2015 | Anaesthetic and respiratory equipment - Breathing sets and connectors (ISO 5367:2014) |
CSA C22.2 No. 80601-2-12 : 2012 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-12: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF CRITICAL CARE VENTILATORS |
ISO 5367:2014 | Anaesthetic and respiratory equipment — Breathing sets and connectors |
16/30312315 DC : 0 | BS EN ISO 80601-2-55 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-55: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF RESPIRATORY GAS MONITORS |
15/30317874 DC : 0 | BS EN 16844 - AESTHETIC MEDICINE SERVICES - NON-SURGICAL MEDICAL PROCEDURES |
16/30295446 DC : 0 | BS ISO 19223 - LUNG VENTILATORS AND RELATED EQUIPMENT - VOCABULARY AND SEMANTICS |
UNE-EN 16372:2015 | Aesthetic surgery services |
12/30254927 DC : 0 | BS EN 16372 - AESTHETIC SURGERY SERVICES |
ISO 8835-7:2011 | Inhalational anaesthesia systems — Part 7: Anaesthetic systems for use in areas with limited logistical supplies of electricity and anaesthetic gases |
I.S. EN 16372:2014 | AESTHETIC SURGERY SERVICES |
CSA Z5359 : 2016 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - LOW-PRESSURE HOSE ASSEMBLIES FOR USE WITH MEDICAL GASES, MEDICAL VACUUM, MEDICAL SUPPORT GASES, AND ANAESTHETIC GAS SCAVENGING SYSTEMS |
IEC TR 60601-4-1:2017 | Medical electrical equipment - Part 4-1: Guidance and interpretation - Medical electrical equipment and medical electrical systems employing a degree of autonomy |
I.S. EN ISO 80601-2-12:2011 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-12: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF CRITICAL CARE VENTILATORS (ISO 80601-2-12:2011/COR 1:2011) |
BS EN ISO 5359 : 2014 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - LOW-PRESSURE HOSE ASSEMBLIES FOR USE WITH MEDICAL GASES |
EN 16844:2017 | Aesthetic medicine services - Non-surgical medical treatments |
EN ISO 80601-2-55:2018 | Medical electrical equipment - Part 2-55: Particular requirements for the basic safety and essential performance of respiratory gas monitors (ISO 80601-2-55:2018) |
CSA C22.2 No. 80601-2-12 : 2012(R2017) | MEDICAL ELECTRICAL EQUIPMENT - PART 2-12: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF CRITICAL CARE VENTILATORS |
BS ISO 18835:2015 | Inhalational anaesthesia systems. Draw-over anaesthetic systems |
17/30338756 DC : 0 | BS ISO 80601-2-80 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-80: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF VENTILATORY SUPPORT EQUIPMENT FOR VENTILATORY INSUFFICIENCY |
13/30264413 DC : 0 | BS EN ISO 80601-2-72 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-72: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF HOME HEALTHCARE ENVIRONMENT VENTILATORS FOR VENTILATOR-DEPENDENT PATIENTS |
13/30272807 DC : 0 | BS ISO 18835 - INHALATIONAL ANAESTHESIA SYSTEMS - DRAW-OVER VAPORIZERS AND ASSOCIATED EQUIPMENT |
12/30244415 DC : DRAFT APR 2012 | BS ISO 27427 - ANAESTHETIC AND RESPIRATORY EQUIPMENT - NEBULIZING SYSTEMS AND COMPONENTS |
CSA C22.2 No. 80601-2-55 : 2014(R2019) | MEDICAL ELECTRICAL EQUIPMENT - PART 2-55: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF RESPIRATORY GAS MONITORS |
I.S. EN ISO 80601-2-72:2015 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-72: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF HOME HEALTHCARE ENVIRONMENT VENTILATORS FOR VENTILATOR-DEPENDENT PATIENTS (ISO 80601-2-72:2015) |
ISO 80601-2-70:2015 | Medical electrical equipment Part 2-70: Particular requirements for basic safety and essential performance of sleep apnoea breathing therapy equipment |
ISO 80601-2-72:2015 | Medical electrical equipment — Part 2-72: Particular requirements for basic safety and essential performance of home healthcare environment ventilators for ventilator-dependent patients |
EN 16372:2014 | Aesthetic surgery services |
EN ISO 80601-2-72:2015 | Medical electrical equipment - Part 2-72: Particular requirements for basic safety and essential performance of home healthcare environment ventilators for ventilator-dependent patients (ISO 80601-2-72:2015) |
EN ISO 5367:2014 | Anaesthetic and respiratory equipment - Breathing sets and connectors (ISO 5367:2014) |
12/30210881 DC : DRAFT APR 2012 | BS EN ISO 5367 - ANAESTHETIC AND RESPIRATORY EQUIPMENT - BREATHING SETS AND CONNECTORS |
CSA ISO 27427 : 2014 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - NEBULIZING SYSTEMS AND COMPONENTS |
I.S. EN ISO 5359:2014 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - LOW-PRESSURE HOSE ASSEMBLIES FOR USE WITH MEDICAL GASES (ISO 5359:2014) |
BS EN 16372:2014 | Aesthetic surgery services |
BS ISO 27427:2013 | Anaesthetic and respiratory equipment. Nebulizing systems and components |
CAN/CSA-C22.2 NO. 80601-2-70:17 | Medical electrical equipment — Part 2-70: Particular requirements for basic safety and essential performance of sleep apnoea breathing therapy equipment (Adopted ISO 80601-2-70:2015, first edition, 2015-01 , with Canadian deviations) |
DIN EN ISO 5367:2015-02 | Anaesthetic and respiratory equipment - Breathing sets and connectors (ISO 5367:2014) |
I.S. EN ISO 5367:2014 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - BREATHING SETS AND CONNECTORS (ISO 5367:2014) |
I.S. EN ISO 80601-2-55:2018 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-55: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF RESPIRATORY GAS MONITORS (ISO 80601-2-55:2018) |
ISO 80601-2-55:2018 | Medical electrical equipment — Part 2-55: Particular requirements for the basic safety and essential performance of respiratory gas monitors |
DIN EN ISO 5359:2015-02 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - LOW-PRESSURE HOSE ASSEMBLIES FOR USE WITH MEDICAL GASES (ISO 5359:2014) |
BS EN 16844 : 2017 | AESTHETIC MEDICINE SERVICES - NON-SURGICAL MEDICAL TREATMENTS |
ISO 18835:2015 | Inhalational anaesthesia systems Draw-over anaesthetic systems |
ISO 27427:2013 | Anaesthetic and respiratory equipment — Nebulizing systems and components |
OVE/ONORM EN ISO 80601-2-12 : 2012 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-12: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF CRITICAL CARE VENTILATORS (ISO/IEC 80601-2-12:2011 + COR.:2011) |
ISO 8836:2014 | Suction catheters for use in the respiratory tract |
EN 15986:2011 | Symbol for use in the labelling of medical devices - Requirements for labelling of medical devices containing phthalates |
IEC 60601-1:2005+AMD1:2012 CSV | Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
IEC TR 60083:2015 | Plugs and socket-outlets for domestic and similar general use standardized in member countries of IEC |
IEC 60601-1-6:2010+AMD1:2013 CSV | Medical electrical equipment - Part 1-6: General requirements for basic safety and essential performance - Collateral standard: Usability |
BS 4272-3:1989 | Anaesthetic and analgesic machines Specification for continuous flow anaesthetic machines |
ISO 13485:2016 | Medical devices Quality management systems Requirements for regulatory purposes |
ISO 5356-1:2015 | Anaesthetic and respiratory equipment Conical connectors Part 1: Cones and sockets |
ISO 9170-2:2008 | Terminal units for medical gas pipeline systems — Part 2: Terminal units for anaesthetic gas scavenging systems |
ISO 10651-4:2002 | Lung ventilators — Part 4: Particular requirements for operator-powered resuscitators |
IEC 60601-1-10:2007+AMD1:2013 CSV | Medical electrical equipment - Part 1-10: General requirements forbasic safety and essential performance - Collateral Standard: Requirements for the development of physiologic closed-loopcontrollers |
ISO 8835-7:2011 | Inhalational anaesthesia systems — Part 7: Anaesthetic systems for use in areas with limited logistical supplies of electricity and anaesthetic gases |
ISO/TR 14969:2004 | Medical devices Quality management systems Guidance on the application of ISO 13485: 2003 |
IEC 60079-20-1:2010 | Explosive atmospheres - Part 20-1: Material characteristics for gas and vapour classification - Test methods and data |
IEC 60601-1-8:2006+AMD1:2012 CSV | Medical electrical equipment - Part 1-8: General requirements forbasic safety and essential performance - Collateral Standard: General requirements, tests and guidance for alarm systems inmedical electrical equipment and medical electrical systems |
ISO 7396-2:2007 | Medical gas pipeline systems Part 2: Anaesthetic gas scavenging disposal systems |
ISO 5145:2014 | Cylinder valve outlets for gases and gas mixtures Selection and dimensioning |
ISO 5356-2:2012 | Anaesthetic and respiratory equipment — Conical connectors — Part 2: Screw-threaded weight-bearing connectors |
ISO 10079-1:2015 | Medical suction equipment Part 1: Electrically powered suction equipment |
ISO 5367:2014 | Anaesthetic and respiratory equipment — Breathing sets and connectors |
IEC 60601-1-2:2014 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
ISO 5362:2006 | Anaesthetic reservoir bags |
IEC 60079-11:2011 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
ISO 8185:2007 | Respiratory tract humidifiers for medical use Particular requirements for respiratory humidification systems |
ISO/TR 16142:2006 | Medical devices Guidance on the selection of standards in support of recognized essential principles of safety and performance of medical devices |
ISO 3746:2010 | Acoustics Determination of sound power levels and sound energy levels of noise sources using sound pressure Survey method using an enveloping measurement surface over a reflecting plane |
ASTM F 2761 : 2009 : R2013 | Medical Devices and Medical Systems - Essential safety requirements for equipment comprising the patient-centric integrated clinical environment (ICE) - Part 1: General requirements and conceptual model |
IEC 60601-1-3:2008+AMD1:2013 CSV | Medical electrical equipment - Part 1-3: General requirements forbasic safety and essential performance - Collateral Standard: Radiation protection in diagnostic X-ray equipment |
ISO 80601-2-55:2011 | Medical electrical equipment Part 2-55: Particular requirements for the basic safety and essential performance of respiratory gas monitors |
ISO 10079-3:2014 | Medical suction equipment Part 3: Suction equipment powered from a vacuum or positive pressure gas source |
ISO 407:2004 | Small medical gas cylinders Pin-index yoke-type valve connections |
ISO 14155:2011 | Clinical investigation of medical devices for human subjects Good clinical practice |
ISO 9170-1:2017 | Terminal units for medical gas pipeline systems — Part 1: Terminal units for use with compressed medical gases and vacuum |
ISO 14971:2007 | Medical devices Application of risk management to medical devices |
ISO 4135:2001 | Anaesthetic and respiratory equipment Vocabulary |
ISO 10524-1:2006 | Pressure regulators for use with medical gases Part 1: Pressure regulators and pressure regulators with flow-metering devices |
ISO 594-2:1998 | Conical fittings with 6 % (Luer) taper for syringes, needles and certain other medical equipment Part 2: Lock fittings |
ISO 15223-1:2016 | Medical devices Symbols to be used with medical device labels, labelling and information to be supplied Part 1: General requirements |
IEC 60601-2-49:2011 | Medical electrical equipment - Part 2-49: Particular requirements for the basic safety and essential performance of multifunction patient monitoring equipment |
IEC 60601-1-9:2007+AMD1:2013 CSV | Medical electrical equipment - Part 1-9: General requirements forbasic safety and essential performance - Collateral Standard: Requirements for environmentally conscious design |
IEC 60601-1-4:1996+AMD1:1999 CSV | Medical electrical equipment - Part 1-4: General requirements for safety - Collateral Standard: Programmable electrical medical systems |
ISO 7396-1:2016 | Medical gas pipeline systems — Part 1: Pipeline systems for compressed medical gases and vacuum |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.