• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ISO 25539-3:2011

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Cardiovascular implants — Endovascular devices — Part 3: Vena cava filters

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Withdrawn date

17-10-2024

Language(s)

French, English

Published date

25-11-2011

£58.00
Excluding VAT

ISO 25539-3:2011 specifies requirements for vena cava filters, based upon current medical knowledge. With regard to safety, it gives requirements for intended performance, design attributes, materials, design evaluation, manufacturing, sterilization, packaging and information supplied by the manufacturer. ISO 25539-3:2011 supplements ISO 14630, which specifies general requirements for the performance of non-active surgical implants.

The following are within the scope of ISO 25539-3:2011:

  • vena cava filters used to prevent pulmonary embolism by mechanical filtration in the inferior vena cava: while ISO 25539-3:2011 might be useful with respect to filters implanted in other venous locations (e.g. superior vena cava, iliac veins), it does not specifically address use of filters in other implantation sites;
  • sheath/dilator kits, providing that they comprise an integral component of the access, delivery or retrieval/conversion of the vena cava filter.
  • delivery systems, providing that they comprise an integral component of the deployment of the vena cava filter.
  • optional filters that can be retrieved or converted, and permanent filters together with their associated endovascular systems: while ISO 25539-3:2011 might be useful with respect to the evaluation of repositioning filters after chronic implantation, it does not specifically address filter repositioning.

The following are outside the scope of ISO 25539-3:2011:

  • temporary filters (e.g. tethered) that need to be removed after a defined period of time;
  • coatings, surface modifications, and/or drugs;
  • issues associated with viable tissues and non-viable biological materials;
  • degradation and other time-dependent aspects of absorbable materials;
  • procedures and devices (e.g. venous entry needle) used prior to the vena cava filter procedure.

Committee
ISO/TC 150/SC 2
DevelopmentNote
Supersedes ISO/DIS 25539-3. (11/2011)
DocumentType
Standard
Pages
98
PublisherName
International Organization for Standardization
Status
Withdrawn

BS EN ISO 14630:2012 Non-active surgical implants. General requirements
ISO/TS 12417:2011 Cardiovascular implants and extracorporeal systems Vascular device-drug combination products
I.S. EN ISO 14630:2012 NON-ACTIVE SURGICAL IMPLANTS - GENERAL REQUIREMENTS (ISO 14630:2012)
BS EN ISO 12417-1:2015 Cardiovascular implants and extracorporeal systems. Vascular device-drug combination products General requirements
17/30250386 DC : 0 BS ISO 17327-1 - NON-ACTIVE SURGICAL IMPLANTS - IMPLANT COATING - PART 1: GENERAL REQUIREMENTS
UNI EN ISO 14630 : 2013 NON-ACTIVE SURGICAL IMPLANTS - GENERAL REQUIREMENTS
14/30251609 DC : 0 BS EN ISO 12417-1 - CARDIOVASCULAR IMPLANTS AND EXTRACORPOREAL SYSTEMS - VASCULAR DEVICE-DRUG COMBINATION PRODUCTS - PART 1: GENERAL REQUIREMENTS
I.S. EN ISO 12417-1:2015 CARDIOVASCULAR IMPLANTS AND EXTRACORPOREAL SYSTEMS - VASCULAR DEVICE-DRUG COMBINATION PRODUCTS - PART 1: GENERAL REQUIREMENTS (ISO 12417-1:2015)
UNE-EN ISO 12417-1:2016 Cardiovascular implants and extracorporeal systems - Vascular device-drug combination products - Part 1: General requirements (ISO 12417-1:2015)
ISO/TR 12417-2:2017 Cardiovascular implants and extracorporeal systems — Vascular device-drug combination products — Part 2: Local regulatory information
AAMI ISO 12417-1 : 2015 CARDIOVASCULAR IMPLANTS AND EXTRACORPOREAL SYSTEMS - VASCULAR DEVICE-DRUG COMBINATION PRODUCTS - PART 1: GENERAL REQUIREMENTS
DIN EN ISO 14630:2013-03 Non-active surgical implants - General requirements (ISO 14630:2012)
UNE-EN ISO 14630:2013 Non-active surgical implants - General requirements (ISO 14630:2012)
ISO 12417-1:2015 Cardiovascular implants and extracorporeal systems — Vascular device-drug combination products — Part 1: General requirements
EN ISO 14630:2012 Non-active surgical implants - General requirements (ISO 14630:2012)
EN ISO 12417-1:2015 Cardiovascular implants and extracorporeal systems - Vascular device-drug combination products - Part 1: General requirements (ISO 12417-1:2015)
AAMI ISO TIR 12417 : 2011 CARDIOVASCULAR IMPLANTS AND EXTRACORPOREAL SYSTEMS - VASCULAR DEVICE-DRUG COMBINATION PRODUCTS
DIN EN ISO 12417-1:2016-02 Cardiovascular implants and extracorporeal systems - Vascular device-drug combination products - Part 1: General requirements (ISO 12417-1:2015)
ISO 17327-1:2018 Non-active surgical implants — Implant coating — Part 1: General requirements
ISO 14630:2012 Non-active surgical implants — General requirements

ISO 11070:2014 Sterile single-use intravascular introducers, dilators and guidewires
ISO 11137-1:2006 Sterilization of health care products Radiation Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices
ISO 11607-2:2006 Packaging for terminally sterilized medical devices Part 2: Validation requirements for forming, sealing and assembly processes
ISO 10555-2:1996 Sterile, single-use intravascular catheters Part 2: Angiographic catheters
ASTM F 2503 : 2013 : REDLINE Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment
ISO 17475:2005 Corrosion of metals and alloys — Electrochemical test methods — Guidelines for conducting potentiostatic and potentiodynamic polarization measurements
ISO 13485:2016 Medical devices Quality management systems Requirements for regulatory purposes
ISO 14937:2009 Sterilization of health care products General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices
ISO/TR 14969:2004 Medical devices Quality management systems Guidance on the application of ISO 13485: 2003
ASTM G 71 : 1981 GUIDE FOR CONDUCTING AND EVALUATING GALVANIC CORROSION TESTS IN ELECTROLYTES
ISO 11135-1:2007 Sterilization of health care products Ethylene oxide Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices
ISO 14630:2012 Non-active surgical implants — General requirements
ASTM F 2052 : 2015 : REDLINE Standard Test Method for Measurement of Magnetically Induced Displacement Force on Medical Devices in the Magnetic Resonance Environment
ISO/TS 15539:2000 Cardiovascular implants Endovascular prostheses
ASTM F 2213 : 2017 : REDLINE Standard Test Method for Measurement of Magnetically Induced Torque on Medical Devices in the Magnetic Resonance Environment
ISO/TS 12417:2011 Cardiovascular implants and extracorporeal systems Vascular device-drug combination products
EN 12006-3:1998+A1:2009 Non active surgical implants - Particular requirements for cardiac and vascular implants - Part 3: Endovascular devices
ISO 10555-3:2013 Intravascular catheters — Sterile and single-use catheters — Part 3: Central venous catheters
CFR 21(PTS1-99) : 0 FOOD AND DRUGS - FOOD AND DRUG ADMINISTRATION, CHAPTER 1 DEPARTMENT OF HEALTH AND HUMAN SERVICES - PARTS 1-99
ISO 10555-1:2013 Intravascular catheters — Sterile and single-use catheters — Part 1: General requirements
ISO 14155:2011 Clinical investigation of medical devices for human subjects Good clinical practice
ISO 14971:2007 Medical devices Application of risk management to medical devices
ISO 11607-1:2006 Packaging for terminally sterilized medical devices Part 1: Requirements for materials, sterile barrier systems and packaging systems
ASTM D 638 : 2014 : REDLINE Standard Test Method for Tensile Properties of Plastics
ISO 17665-1:2006 Sterilization of health care products — Moist heat — Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices
ASTM F 640 : 2012 : REDLINE Standard Test Methods for Determining Radiopacity for Medical Use

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.