ISO 15712-4:2005
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Building acoustics Estimation of acoustic performance of buildings from the performance of elements Part 4: Transmission of indoor sound to the outside
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
28-09-2018
English, French
05-01-2005
ISO 15712-4:2005 describes a calculation model for the sound power level radiated by the envelope of a building due to airborne sound inside that building, primarily by means of measured sound pressure levels inside the building and measured data which characterize the sound transmission by the relevant elements and openings in the building envelope. These sound power levels, together with those of other sound sources in or in front of the building envelope, form the basis for the calculation of the sound pressure level at a chosen distance from a building as a measure for the acoustic performance of buildings.
The prediction of the inside sound pressure level from knowledge of the indoor sound sources is outside the scope of ISO 15712-4:2005.
The prediction of the outdoor sound propagation is outside the scope of ISO 15712-4:2005.
ISO 15712-4:2005 describes the principles of the calculation model, lists the relevant quantities and defines its applications and restrictions. It is intended for acoustical experts and provides the framework for the development of application documents and tools for other users in the field of building construction, taking into account local circumstances.
DevelopmentNote |
Supersedes ISO/DIS 15712-4 (01/2005)
|
DocumentType |
Standard
|
Pages |
23
|
PublisherName |
International Organization for Standardization
|
Status |
Withdrawn
|
SupersededBy |
ISO 140-5:1998 | Acoustics Measurement of sound insulation in buildings and of building elements Part 5: Field measurements of airborne sound insulation of faade elements and faades |
ISO 140-10:1991 | Acoustics Measurement of sound insulation in buildings and of building elements Part 10: Laboratory measurement of airborne sound insulation of small building elements |
ISO 140-3:1995 | Acoustics — Measurement of sound insulation in buildings and of building elements — Part 3: Laboratory measurements of airborne sound insulation of building elements |
ISO 9613-2:1996 | Acoustics — Attenuation of sound during propagation outdoors — Part 2: General method of calculation |
EN ISO 140-5:1998 | Acoustics - Measurement of sound insulation in buildings and of building elements - Part 5: Field measurements of airborne sound insulation of façade elements and façades (ISO 140-5:1998) |
EN ISO 7235:2009 | Acoustics - Laboratory measurement procedures for ducted silencers and air-terminal units - Insertion loss, flow noise and total pressure loss (ISO 7235:2003) |
EN 12354-1:2000 | Building Acoustics - Estimation of acoustic performance of buildings from the performance of elements - Part 1: Airborne sound insulation between rooms |
EN 12354-3:2000 | Building acoustics - Estimation of acoustic performance of buildings from the performance of elements - Part 3: Airborne sound insulation against outdoor sound |
ISO 717-1:2013 | Acoustics Rating of sound insulation in buildings and of building elements Part 1: Airborne sound insulation |
EN 20140-10 : 1992 | ACOUSTICS - MEASUREMENT OF SOUND INSULATION IN BUILDINGS AND OF BUILDING ELEMENTS - PART 10: LABORATORY MEASUREMENT OF AIRBORNE SOUND INSULATION OF SMALL BUILDING ELEMENTS |
ISO 7235:2003 | Acoustics — Laboratory measurement procedures for ducted silencers and air-terminal units — Insertion loss, flow noise and total pressure loss |