ISO 13253:2017
Current
The latest, up-to-date edition.
Ducted air-conditioners and air-to-air heat pumps — Testing and rating for performance
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
18-07-2017
ISO 13253:2017 specifies performance testing, the standard conditions and the test methods for determining the capacity and efficiency ratings of air-cooled, air-conditioners and air-to-air heat pumps.
ISO 13253:2017 is applicable to the following equipment:
- ducted air-cooled air conditioners and ducted air to air heat pumps.
ISO 13253:2017 is limited to
- residential, commercial and industrial single-package, and split-system air conditioners and heat pumps,
- factory-made, electrically driven and use mechanical compression,
- utilizing single, multiple and variable capacity components, and
- multiple split-system utilizing one or more refrigeration systems, one outdoor unit and one or more indoor units, controlled by a single thermostat/controller.
The requirements of testing and rating contained in this document are based on the use of matched assemblies.
ISO 13253:2017 is not applicable to the rating and testing of the following:
a) water-source heat pumps or water-cooled air-conditioners;
b) multi-split-system air-conditioners and air-to-air heat pumps (see ISO 15042 for testing of such equipment);
c) mobile (windowless) units having a condenser exhaust duct;
d) individual assemblies not constituting a complete refrigeration system;
e) equipment using the absorption refrigeration cycle;
f) non-ducted equipment (see ISO 5151 for testing of such equipment);
g) ducted air conditioners and/or ducted heat pumps, rated at less than 8 kW and intended to operate at external static pressures of less than 25 Pa, controlled by a single thermostat/controller (refer to ISO 5151).
ISO 13253:2017 does not cover the determination of seasonal efficiencies, which can be required in some countries because they provide a better indication of efficiency under actual operating conditions.
NOTE Throughout this document, the terms "equipment" and "systems" mean "air-conditioners" and/or "heat pumps".
DevelopmentNote |
Supersedes ISO/DIS 13253. (07/2017) NEW CHILD AMD 1 IS NOW ADDED
|
DocumentType |
Standard
|
Pages |
89
|
ProductNote |
NEW CHILD AMD 1 IS NOW ADDED
|
PublisherName |
International Organization for Standardization
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NEN ISO 13253 : 2017 | Identical |
BS ISO 13253:2017 | Identical |
ANSI/AHRI/ASHRAE ISO 13256-2 : 1998 : R2012 | WATER-SOURCE HEAT PUMPS - TESTING AND RATING FOR PERFORMANCE - PART 2: WATER-TO-WATER AND BRINE-TO-WATER HEAT PUMPS |
PD CEN ISO/TS 16491:2012 | Guidelines for the evaluation of uncertainty of measurement in air conditioner and heat pump cooling and heating capacity tests |
15/30284307 DC : 0 | BS ISO 5151 - NON-DUCTED AIR CONDITIONERS AND HEAT PUMPS - TESTING AND RATING FOR PERFORMANCE |
12/30234071 DC : 0 | BS ISO 16358-3 - AIR-COOLED AIR CONDITIONERS AND AIR-TO-AIR HEAT PUMPS - TESTING AND CALCULATING METHODS FOR SEASONAL PERFORMANCE FACTORS - PART 3: ANNUAL PERFORMANCE FACTOR |
BS ISO 13380:2002 | Condition monitoring and diagnostics of machines. General guidelines on using performance parameters |
ISO 15042:2017 | Multiple split-system air conditioners and air-to-air heat pumps — Testing and rating for performance |
CSA C748 : 2013 | PERFORMANCE OF DIRECT-EXPANSION (DX) GROUND-SOURCE HEAT PUMPS |
ISO 16358-3:2013 | Air-cooled air conditioners and air-to-air heat pumps — Testing and calculating methods for seasonal performance factors — Part 3: Annual performance factor |
IEC 60335-2-40:2018 | Household and similar electrical appliances - Safety - Part 2-40: Particular requirements for electrical heat pumps, air-conditioners and dehumidifiers |
IEC 60335-2-40:2018 RLV | Household and similar electrical appliances - Safety - Part 2-40: Particular requirements for electrical heat pumps, air-conditioners and dehumidifiers |
CEN ISO/TS 16491:2012 | Guidelines for the evaluation of uncertainty of measurement in air conditioner and heat pump cooling and heating capacity tests (ISO/TS 16491:2012) |
12/30234064 DC : 0 | BS ISO 16358-1 - AIR-COOLED AIR CONDITIONERS AND AIR-TO-AIR HEAT PUMPS - TESTING AND CALCULATING METHODS FOR SEASONAL PERFORMANCE FACTORS - PART 1: COOLING SEASONAL PERFORMANCE FACTOR |
12/30234068 DC : 0 | BS ISO 16358-2 - AIR-COOLED AIR CONDITIONERS AND AIR-TO-AIR HEAT PUMPS - TESTING AND CALCULATING METHODS FOR SEASONAL PERFORMANCE FACTORS - PART 2: HEATING SEASONAL PERFORMANCE FACTOR |
ISO 16358-2:2013 | Air-cooled air conditioners and air-to-air heat pumps Testing and calculating methods for seasonal performance factors Part 2: Heating seasonal performance factor |
BS ISO 16358-3:2013 | Air-cooled air conditioners and air-to-air heat pumps. Testing and calculating methods for seasonal performance factors Annual performance factor |
BS ISO 16358-2:2013 | Air-cooled air conditioners and air-to-air heat pumps. Testing and calculating methods for seasonal performance factors Heating seasonal performance factor |
BS ISO 5151:2017 | Non-ducted air conditioners and heat pumps. Testing and rating for performance |
CSA C13256.1 : 2001 : R2016 | WATER-SOURCE HEAT PUMPS - TESTING AND RATING FOR PERFORMANCE - PART 1: WATER-TO-AIR AND BRINE-TO-AIR HEAT PUMPS |
ISO 16358-1:2013 | Air-cooled air conditioners and air-to-air heat pumps — Testing and calculating methods for seasonal performance factors — Part 1: Cooling seasonal performance factor |
ISO 13261-1:1998 | Sound power rating of air-conditioning and air-source heat pump equipment Part 1: Non-ducted outdoor equipment |
16/30300176 DC : 0 | BS ISO 19659-1 - RAILWAY APPLICATIONS - HEATING, VENTILATION AND AIR CONDITIONING SYSTEMS FOR ROLLING STOCK - PART 1: TERMS AND DEFINITIONS |
UNI ISO 13380 : 2010 | CONDITION MONITORING AND DIAGNOSTICS OF MACHINES - GENERAL GUIDELINES ON USING PERFORMANCE PARAMETERS |
CSA C13256.1:2001 | WATER-SOURCE HEAT PUMPS - TESTING AND RATING FOR PERFORMANCE - PART 1: WATER-TO-AIR AND BRINE-TO-AIR HEAT PUMPS |
00/702358 DC : DRAFT JAN 2000 | ISO/DIS 13380 - CONDITION MONITORING AND DIAGNOSTICS OF MACHINES - USE OF PERFORMANCE PARAMETERS - GENERAL GUIDELINES |
CSA PLUS 14021 : 2008 | ENVIRONMENTAL CLAIMS: A GUIDE FOR INDUSTRY AND ADVERTISERS |
S.R. CEN ISO/TS 16491:2012 | GUIDELINES FOR THE EVALUATION OF UNCERTAINTY OF MEASUREMENT IN AIR CONDITIONER AND HEAT PUMP COOLING AND HEATING CAPACITY TESTS (ISO/TS 16491:2012) |
EN ISO 14021:2016 | Environmental labels and declarations - Self-declared environmental claims (Type II environmental labelling) (ISO 14021:2016) |
UNE-EN ISO 14021:2017 | Environmental labels and declarations - Self-declared environmental claims (Type II environmental labelling) (ISO 14021:2016) |
ASHRAE HDBK REFRIGERATION : 2014 | ASHRAE HANDBOOK - REFRIGERATION |
BS ISO 15042:2017 | Multiple split-system air conditioners and air-to-air heat pumps. Testing and rating for performance |
BS ISO 16358-1:2013 | Air-cooled air conditioners and air-to-air heat pumps. Testing and calculating methods for seasonal performance factors Cooling seasonal performance factor |
ISO 5151:2017 | Non-ducted air conditioners and heat pumps — Testing and rating for performance |
CSA C13256.2 : 2001 : R2015 | WATER-SOURCE HEAT PUMPS - TESTING AND RATING FOR PERFORMANCE - PART 2: WATER-TO-WATER AND BRINE-TO-WATER HEAT PUMPS |
CSA C13256.2 : 2001 | WATER-SOURCE HEAT PUMPS - TESTING AND RATING FOR PERFORMANCE - PART 2: WATER-TO-WATER AND BRINE-TO-WATER HEAT PUMPS |
I.S. EN ISO 14021:2016 | ENVIRONMENTAL LABELS AND DECLARATIONS - SELF-DECLARED ENVIRONMENTAL CLAIMS (TYPE 2 ENVIRONMENTAL LABELLING) (ISO 14021:2016) |
ISO 14021:2016 | Environmental labels and declarations — Self-declared environmental claims (Type II environmental labelling) |
ISO/TS 16491:2012 | Guidelines for the evaluation of uncertainty of measurement in air conditioner and heat pump cooling and heating capacity tests |
BS EN ISO 14021:2016 | Environmental labels and declarations. Self-declared environmental claims (Type II environmental labelling) |
ANSI/AHRI/ASHRAE ISO 13256-2 : 1998 | WATER-SOURCE HEAT PUMPS - TESTING AND RATING FOR PERFORMANCE - PART 2: WATER-TO-WATER AND BRINE-TO-WATER HEAT PUMPS |
15/30284304 DC : 0 | BS ISO 15042 - MULTIPLE SPLIT-SYSTEM AIR-CONDITIONERS AND AIR-TO-AIR HEAT PUMPS - TESTING AND RATING FOR PERFORMANCE |
ANSI/AHRI/ASHRAE ISO 13256-1 : 1998 : R2012 | WATER-SOURCE HEAT PUMPS - TESTING AND RATING FOR PERFORMANCE - PART 1: WATER-TO-AIR AND BRINE-TO-AIR HEAT PUMPS |
CSA C13256.2 : 2001 : R2005 | WATER-SOURCE HEAT PUMPS - TESTING AND RATING FOR PERFORMANCE - PART 2: WATER-TO-WATER AND BRINE-TO-WATER HEAT PUMPS |
ANSI/AHRI/ASHRAE ISO 13256-1:1998 | WATER-SOURCE HEAT PUMPS - TESTING AND RATING FOR PERFORMANCE - PART 1: WATER-TO-AIR AND BRINE-TO-AIR HEAT PUMPS |
ISO 13380:2002 | Condition monitoring and diagnostics of machines General guidelines on using performance parameters |
AHRI 340/360 (I-P) : 2015 | PERFORMANCE RATING OF COMMERCIAL AND INDUSTRIAL UNITARY AIR-CONDITIONING AND HEAT PUMP EQUIPMENT |
ISO 5151:2017 | Non-ducted air conditioners and heat pumps — Testing and rating for performance |
ISO 5167-1:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements |
ISO 15042:2017 | Multiple split-system air conditioners and air-to-air heat pumps — Testing and rating for performance |
ISO 817:2014 | Refrigerants Designation and safety classification |
ISO 3966:2008 | Measurement of fluid flow in closed conduits Velocity area method using Pitot static tubes |
ISO/TS 16491:2012 | Guidelines for the evaluation of uncertainty of measurement in air conditioner and heat pump cooling and heating capacity tests |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.