• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ISO 11318:2002

Current

Current

The latest, up-to-date edition.

Cardiac defibrillators — Connector assembly DF-1 for implantable defibrillators — Dimensions and test requirements

Available format(s)

PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English, French

Published date

15-08-2002

This International Standard specifies a unipolar connector assembly, DF-1, intended for use in connecting implantable defibrillator leads to implantable defibrillator generators that do not produce more than 1 kV/50 A peak output. Essential dimensions and performance requirements related to connector fit are specified, along with test methods.

This International Standard does not specify other connector features such as fastening means and material. This International Standard is applicable to the form and fit of the connector assembly, and does not address all aspects of functional compatibility, system performance, or reliability of different implantable defibrillator leads and implantable defibrillator generator assemblies.

Committee
ISO/TC 150/SC 6
DevelopmentNote
Supersedes ISO/DIS 11318 (08/2002)
DocumentType
Standard
Pages
21
PublisherName
International Organization for Standardization
Status
Current
Supersedes

Standards Relationship
NEN ISO 11318 : 2002 Identical
GOST R ISO 11318 : 2010 Identical
BS ISO 11318:2002 Identical
IS 17709 : 2022 Identical
BS 7778:1994 Identical

NF EN 45502-2-1 : 2004 ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 2-1: PARTICULAR REQUIREMENTS FOR ACTIVE IMPLANTABLE MEDICAL DEVICES INTENDED TO TREAT BRADYARRHYTHMIA (CARDIAC PACEMAKERS)
ISO 16142-1:2016 Medical devices — Recognized essential principles of safety and performance of medical devices — Part 1: General essential principles and additional specific essential principles for all non-IVD medical devices and guidance on the selection of standards
AAMI ISO 27186 : 2010 ACTIVE IMPLANTABLE MEDICAL DEVICES - FOUR-POLE CONNECTOR SYSTEM FOR IMPLANTABLE CARDIAC RHYTHM MANAGEMENT DEVICES - DIMENSIONAL AND TEST REQUIREMENTS
08/30191626 DC : DRAFT OCT 2008 BS ISO 27186 - ACTIVE IMPLANTABLE MEDICAL DEVICES - FOUR-POLE CONNECTOR SYSTEM FOR IMPLANTABLE CARDIAC RHYTHM MANAGEMENT DEVICES - DIMENSIONAL AND TEST REQUIREMENTS
BS ISO 27186:2010 Active implantable medical devices. Four-pole connector system for implantable cardiac rhythm management devices. Dimensional and test requirements
BS EN 45502-2-1:2003 Active implantable medical devices Particular requirements for active implantable medical devices intended to treat bradyarrhythmia (cardiac pacemakers)
EN 45502-2-2 : 2008 COR 2009 ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 2-2: PARTICULAR REQUIREMENTS FOR ACTIVE IMPLANTABLE MEDICAL DEVICES INTENDED TO TREAT TACHYARRHYTHMIA (INCLUDES IMPLANTABLE DEFIBRILLATORS)
08/30191609 DC : DRAFT DEC 2008 BS ISO 14708-6 - IMPLANTS FOR SURGERY - ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 6: PARTICULAR REQUIREMENTS FOR ACTIVE IMPLANTABLE MEDICAL DEVICES INTENDED TO TREAT TACHYARRHYTHMIA (INCLUDING IMPLANTABLE DEFIBRILLATORS)
BS ISO 16142-1:2016 Medical devices. Recognized essential principles of safety and performance of medical devices General essential principles and additional specific essential principles for all non-IVD medical devices and guidance on the selection of standards
BS EN 45502-2-2:2008 Active implantable medical devices Particular requirements for active implantable medical devices intended to treat tachyarrhythmia (includes implantable defibrillators)
ISO 14708-6:2010 Implants for surgery Active implantable medical devices Part 6: Particular requirements for active implantable medical devices intended to treat tachyarrhythmia (including implantable defibrillators)
ISO 27186:2010 Active implantable medical devices Four-pole connector system for implantable cardiac rhythm management devices - Dimensional and test requirements
ISO 14708-2:2012 Implants for surgery Active implantable medical devices Part 2: Cardiac pacemakers
AAMI TIR41 : 2011 ACTIVE IMPLANTABLE MEDICAL DEVICES - GUIDANCE FOR DESIGNATION OF LEFT VENTRICLE AND IMPLANTABLE CARDIOVERTER DEFIBRILLATOR LEAD CONNECTORS AND PULSE GENERATOR CONNECTOR CAVITIES FOR IMPLANTABLE PACEMAKERS AND IMPLANTABLE CARDIOVERTER DEFIBRILLATORS
NF EN 45502-2-2 : 2008 ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 2-2: PARTICULAR REQUIREMENTS FOR ACTIVE IMPLANTABLE MEDICAL DEVICES INTENDED TO TREAT TACHYARRHYTHMIA (INCLUDES IMPLANTABLE DEFIBRILLATORS)
I.S. EN 45502-2-2:2008 ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 2-2: PARTICULAR REQUIREMENTS FOR ACTIVE IMPLANTABLE MEDICAL DEVICES INTENDED TO TREAT TACHYARRHYTHMIA (INCLUDES IMPLANTABLE DEFIBRILLATORS)
I.S. EN 45502-2-1:2004 ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 2-1: PARTICULAR REQUIREMENTS FOR ACTIVE IMPLANTABLE MEDICAL DEVICES INTENDED TO TREAT BRADYARRHYTHMIA (CARDIAC PACEMAKERS)
EN 45502-2-2 : 2008 COR 2009 ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 2-2: PARTICULAR REQUIREMENTS FOR ACTIVE IMPLANTABLE MEDICAL DEVICES INTENDED TO TREAT TACHYARRHYTHMIA (INCLUDES IMPLANTABLE DEFIBRILLATORS)

ISO 7436:1983 Slotted set screws with cup point

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.