ISA 61241-2 : 2006
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
ELECTRICAL APPARATUS FOR USE IN ZONE 21 AND ZONE 22 HAZARDOUS (CLASSIFIED) LOCATIONS - PROTECTION BY PRESSURIZATION "PD"
Hardcopy , PDF
19-03-2021
English
01-01-2006
Foreword
1 Scope
2 References
3 Definitions
4 Pressurization principle
4.1 Protective gas
4.2 Automatic disconnection or alarm
4.3 Cleaning
4.4 Discharge of protective gas
5 General constructional requirements
5.1 Electrical performance of apparatus
5.2 Mechanical strength
5.3 Apertures
5.5 Doors and covers
6 Temperature limits
7 Safety provisions and safety devices (except for
static pressurization)
7.1 General
7.2 Pressure- or flow-activated devices
7.4 Switching off electrical supply
7.5 Failure of pressurization
7.6 Level of overpressure
7.7 Possible sources of ignition
7.8 Enclosed components
7.9 Separate enclosures
8 Safety provisions and safety devices for static
pressurization
9 Supply of protective gas
9.1 Type of gas
9.2 Second source of supply
9.3 Temperature
10 Verification and tests
10.1 General
10.2 Type verification and tests
10.3 Overpressure test
10.4 Minimum overpressure test
10.5 Leakage test
10.7 Routine tests
11 Marking
11.1 Pressurized enclosure
11.2 Additional marking
11.3 Pressurized enclosures protected by static
pressurization
11.4 Any other marking required
11.5 Warnings required in other clauses:
Annex A (normative) Ducts for protective gas supply
Annex B (normative) Installation requirements for
pressurization
B.1 Source of protective gas
B.2 Automatic switch-off
B.3 Manual switch-off
B.4 Common supply of protective gas
B.5 Switching off electrical supply
Annex C (informative) Explanation of National Deviations
Provides requirements on the design, construction, testing and marking of electrical apparatus for use in combustible dust atmospheres in which a protective gas (air or inert gas), maintained at a pressure above that of the external atmosphere, is used to prevent the entry of dust which might otherwise lead to the formation of a combustible mixture within enclosures which do not contain a source of combustible dust.
DocumentType |
Standard
|
Pages |
36
|
PublisherName |
International Society of Automation
|
Status |
Superseded
|
SupersededBy |
CSA C22.4 No. 1 : 2009(R2018) | OBJECTIVE-BASED INDUSTRIAL ELECTRICAL CODE |
FM 3600 : 2018 | ELECTRICAL EQUIPMENT FOR USE IN HAZARDOUS (CLASSIFIED) LOCATIONS - GENERAL REQUIREMENTS |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
CSA C22.4 PACKAGE : 2009 | CONSISTS OF C22.4 NO. 1-09, OBJECTIVE-BASED INDUSTRIAL ELECTRICAL CODE AND C22.4 NO. 2-09, OBJECTIVE-BASED INDUSTRIAL ELECTRICAL CODE - SAFETY MANAGEMENT SYSTEM REQUIREMENTS |
ISA 61241-10 : 2004 | ELECTRICAL APPARATUS FOR USE IN ZONE 20, ZONE 21 AND ZONE 22 HAZARDOUS (CLASSIFIED) LOCATIONS - CLASSIFICATION OF ZONE 20, ZONE 21 AND ZONE 22 HAZARDOUS (CLASSIFIED) LOCATIONS |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
IEC 60034-1:2017 | Rotating electrical machines - Part 1: Rating and performance |
ISA 61241-0 : 2006 | ELECTRICAL APPARATUS FOR USE IN ZONE 20, ZONE 21 AND ZONE 22 HAZARDOUS (CLASSIFIED) LOCATIONS - GENERAL REQUIREMENTS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.