1 Overview
2 Normative references
3 Definitions
4 Service conditions
5 Rating data
6 Construction
7 Short-circuit characteristics
8 Testing and calculations
9 Tolerances
10 Connection of transformers for shipment
Annex A (informative) - Bibliography
Annex B (informative) - Insulation at high
        altitude

Defines electrical and mechanical requirements of single and polyphase ventilated, nonventilated, and sealed dry-type distribution and power transformers or autotransformers, with a voltage of 601 V or higher in the highest voltage winding.

Committee
Transformers
DevelopmentNote
Supersedes IEEE DRAFT C57.12.01. (05/2006)
DocumentType
Standard
ISBN
978-0-7381-9499-8
Pages
85
PublisherName
Institute of Electrical & Electronics Engineers
Status
Superseded
SupersededBy
Supersedes

IEEE 141 : 1993 IEEE Recommended Practice for Electric Power Distribution for Industrial Plants
IEEE C57.94-1982 IEEE Recommended Practice for Installation, Application, Operation, and Maintenance of Dry-Type General Purpose Distribution and Power Transformers
IEEE DRAFT C57.123 : D1.7 OCT 2000 DRAFT GUIDE FOR TRANSFORMER LOSS MEASUREMENT
IEEE 1653.2-2009 IEEE Standard for Uncontrolled Traction Power Rectifiers for Substation Applications Up to 1500 V DC Nominal Output
IEEE DRAFT C62.22 : D8 2005 GUIDE FOR THE APPLICATION OF METAL-OXIDE SURGE ARRESTERS FOR ALTERNATING-CURRENT SYSTEMS
IEEE C57.32-2015 IEEE Standard for Requirements, Terminology, and Test Procedures for Neutral Grounding Devices
IEEE C57.123-2010 REDLINE IEEE Guide for Transformer Loss Measurement
IEEE C57.12.51-2008 IEEE Standard for Ventilated Dry- Type Power Transformers, 501 kVA and Larger, Three-Phase, with High- Voltage 601 V to 34 500 V; Low- Voltage 208Y/120 V to 4160 V- General Requirements
IEEE DRAFT C57.12.91 : D3 2000 DRAFT STANDARD TEST CODE FOR DRY-TYPE DISTRIBUTION AND POWER TRANSFORMERS
IEEE DRAFT 833 : D3 2004 PRACTICE FOR THE PROTECTION OF ELECTRIC EQUIPMENT IN NUCLEAR POWER GENERATING STATIONS FROM WATER HAZARDS
IEEE DRAFT 1147 : D8 2005 GUIDE FOR THE REHABILITATION OF HYDROELECTRIC POWER PLANTS
IEEE 1566-2015 IEEE Standard for Performance of Adjustable-Speed AC Drives Rated 375 kW and Larger
IEEE C57.110-2008 REDLINE IEEE Recommended Practice for Establishing Liquid-Filled and Dry-Type Power and Distribution Transformer Capability When Supplying Nonsinusoidal Load Currents
IEEE DRAFT C57.12.60 : OCT 97 DRAFT GUIDE FOR TEST PROCEDURES FOR THERMAL EVALUATION OF INSULATION SYSTEMS FOR SOLID-CAST AND RESIN-ENCAPSULATED POWER AND DISTRIBUTION TRANSFORMERS
IEEE DRAFT C57.110 : D7 FEB 98 DRAFT RECOMMENDED PRACTICE FOR ESTABLISHING TRANSFORMER CAPABILITY WHEN SUPPLYING NONSINUSOIDAL LOAD CURRENTS
IEEE C57.98-2011 IEEE Guide for Transformer Impulse Tests
IEEE C57.96-2013 IEEE Guide for Loading Dry-Type Distribution and Power Transformers
ANSI C57.12.52 : 2012 Sealed Dry-Type Power Transformers, 501 kVA and Higher, Three-Phase, with High-Voltage 601 to 34500 Volts, Low-Voltage 208Y/120 to 4160 Volts—General Requirements
IEEE C37.302-2015 IEEE Guide for Fault Current Limiter (FCL) Testing of FCLs Rated above 1000 V AC
NEMA ST 20:2014 Dry Type Transformers for General Applications
NEMA TP 2-2005 STANDARD TEST METHOD FOR MEASURING THE ENERGY CONSUMPTION OF DISTRIBUTION TRANSFORMERS
NEMA TR1 : 2013 TRANSFORMERS, STEP VOLTAGE REGULATORS AND REACTORS
IEEE 1100 : 2005 POWERING AND GROUNDING ELECTRONIC EQUIPMENT
UFC 3-550-01 : CHANGE 1 UNIFIED FACILITIES CRITERIA - EXTERIOR ELECTRICAL POWER DISTRIBUTION
IEEE C57.116-2014 IEEE Guide for Transformers Directly Connected to Generators
IEEE C57.12.11-1980 IEEE Guide for Installation of Oil-Immersed Transformers (10 MVA and Larger, 69-287 kV Rating)
IEEE DRAFT C37.91 : D7.0 2006 PROTECTING POWER TRANSFORMERS
IEEE 421.3-1997 IEEE Standard for High-Potential Test Requirements for Excitation Systems for Synchronous Machines
IEEE 638-2013 IEEE Standard for Qualification of Class 1E Transformers for Nuclear Power Generating Stations
IEEE DRAFT C57.18.10 : D12 APR 97 DRAFT PRACTICES AND REQUIREMENTS FOR SEMICONDUCTOR POWER RECTIFIER TRANSFORMER
IEEE C57.12.60-2009 REDLINE IEEE Standard Test Procedure for Thermal Evaluation of Insulation Systems for Dry-Type Power and Distribution Transformers, Including Open-Wound, Solid-Cast, and Resin-Encapsulated Transformers
API 540 : 1999 : R2006 ELECTRICAL INSTALLATIONS IN PETROLEUM PROCESSING PLANTS
IEEE 3001.5-2013 IEEE Recommended Practice for the Application of Power Distribution Apparatus in Industrial and Commercial Power Systems
IEEE 1531-2003 IEEE Guide for Application and Specification of Harmonic Filters
IEEE C57.134-2013 IEEE Guide for Determination of Hottest-Spot Temperature in Dry-Type Transformers
IEEE DRAFT C57.96 : D4.0 JAN 99 DRAFT GUIDE FOR LOADING DRY-TYPE DISTRIBUTION AND POWER TRANSFORMERS
IEEE DRAFT 1313.2 : D6 DEC 98 DRAFT GUIDE FOR THE APPLICATION OF INSULATED COORDINATION
ANSI C57.12.57 : 1987 AMERICAN NATIONAL STANDARD FOR TRANSFORMERS - VENTILATED DRY-TYPE NETWORK TRANSFORMERS 2500 KVA AND BELOW, THREE-PHASE, WITH HIGH-VOLTAGE 34500 VOLTS AND BELOW, LOW-VOLTAGE 216Y/125 AND 480Y/227 VOLTS - REQUIREMENTS
IEEE C57.159-2016 IEEE Guide on Transformers for Application in Distributed Photovoltaic (DPV) Power Generation Systems
IEEE C57.12.59-2015 IEEE Guide for Dry-Type Transformer Through-Fault Current Duration
IEEE C57.12.50 : 1981 REQUIREMENTS FOR VENTILATED DRY-TYPE DISTRIBUTION TRANSFORMERS, 1 TO 500 KVA, SINGLE-PHASE, AND 15 TO 500 KVA, THREE-PHASE, WITH HIGH-VOLTAGE 601 TO 34500 VOLTS, LOW-VOLTAGE 120 TO 600 VOLTS
IEEE C37.121-2012 GUIDE FOR SWITCHGEAR - UNIT SUBSTATION - REQUIREMENTS
IEEE C57.12.52-2012 IEEE Standard for Sealed Dry-Type Power Transformers, 501 kVA and Higher, Three-Phase, with High-Voltage 601 to 34500 Volts, Low-Voltage 208Y/120 to 4160 Volts—General Requirements
IEEE C57.12.91-2011 IEEE Standard Test Code for Dry-Type Distribution and Power Transformers
IEEE DRAFT 1531 : D2 OCT 2000 DRAFT GUIDE FOR APPLICATION FOR SPECIFICATION OF HARMONIC FILTERS
API 540:1999 ELECTRICAL INSTALLATIONS IN PETROLEUM PROCESSING PLANTS
IEEE 242-2001 IEEE Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems (IEEE Buff Book)
IEEE 1147-2005 IEEE Guide for the Rehabilitation of Hydroelectric Power Plants
IEEE 241 : 1990 ELECTRIC POWER SYSTEMS IN COMMERCIAL BUILDINGS
IEEE C57.12.70-2011 IEEE Standard for Standard Terminal Markings and Connections for Distribution and Power Transformers
IEEE DRAFT 1313.1 : D11 MAY 95 INSULATION COORDINATION - DEFINITIONS, PRINCIPLES AND RULES
IEEE 1653.1-2016 IEEE Standard for Traction Power Rectifier Transformers for Substation Applications up to 1500 V DC Nominal Output
C9-17 Dry-type transformers
IEEE 1313.1-1996 IEEE Standard for Insulation Coordination - Definitions, Principles and Rules
IEEE C37.121-2012 REDLINE IEEE Guide for Switchgear - Unit Substation - Requirements
ASHRAE 90.4 : 2016 ENERGY STANDARD FOR DATA CENTERS
IEEE C57.110-2018 IEEE Recommended Practice for Establishing Liquid Immersed and Dry-Type Power and Distribution Transformer Capability when Supplying Nonsinusoidal Load Currents
IEEE 1653.2-2020 IEEE Standard for Uncontrolled Traction Power Rectifiers for Substation Applications up to 1500 V DC Nominal Output
IEEE/IEC 60076-16-2018 IEC/IEEE International Standard - Power transformers - Part 16: Transformers for wind turbine applications
IEEE C57.12.51-2019 IEEE Guide for Mechanical Interchangeability of Ventilated Dry-Type Transformers
IEEE C57.94-2015 IEEE Recommended Practice for Installation, Application, Operation, and Maintenance of Dry-Type Distribution and Power Transformers
IEEE C57.123-2019 IEEE Guide for Transformer Loss Measurement
IEEE/IEC 60214-2-2019 IEEE/IEC International Standard for TAP-changers --Part 2: Application guidelines
IEEE C57.12.60-2020 IEEE Standard for Thermal Evaluation of Insulation Systems for Dry-Type Power and Distribution Transformers
IEEE 421.3-2016 IEEE Standard for High-Potential Test Requirements for Excitation Systems for Synchronous Machines

IEEE C57.12.60-2009 REDLINE IEEE Standard Test Procedure for Thermal Evaluation of Insulation Systems for Dry-Type Power and Distribution Transformers, Including Open-Wound, Solid-Cast, and Resin-Encapsulated Transformers
IEEE C57.96-2013 IEEE Guide for Loading Dry-Type Distribution and Power Transformers
IEEE C57.12.80-2010 IEEE Standard Terminology for Power and Distribution Transformers
IEEE 315 : 1975 GRAPHIC SYMBOLS FOR ELECTRICAL AND ELECTRONICS DIAGRAMS (INCLUDING REFERENCE DESIGNATION LETTERS)
IEEE C57.124 : 1991 RECOMMENDED PRACTICE FOR THE DETECTION OF PARTIAL DISCHARGE AND THE MEASUREMENT OF APPARENT CHARGE IN DRY-TYPE TRANSFORMERS
ANSI C84.1 : 2016 ELECTRIC POWER SYSTEMS AND EQUIPMENT - VOLTAGE RATINGS (60 HERTZ)
IEEE C57.142 : 2010 GUIDE TO DESCRIBE THE OCCURRENCE AND MITIGATION OF SWITCHING TRANSIENTS INDUCED BY TRANSFORMERS, SWITCHING DEVICE, AND SYSTEM INTERACTION
IEEE C57.12.70-2011 IEEE Standard for Standard Terminal Markings and Connections for Distribution and Power Transformers
IEEE C57.12.91-2011 IEEE Standard Test Code for Dry-Type Distribution and Power Transformers

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.