• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

IEEE 43-2013 REDLINE

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

IEEE Recommended Practice for Testing Insulation Resistance of Electric Machinery

Available format(s)

PDF

Withdrawn date

21-03-2024

Language(s)

English

Published date

06-03-2014

£97.03
Excluding VAT

1 Overview
2 Normative references
3 Definitions
4 Safety considerations
5 Insulation resistance-general theory
6 Factors affecting insulation resistance
7 Conditions for measuring insulation resistance
8 Winding connections for insulation
   resistance tests
9 Methods of measuring insulation resistance
10 Precautions
11 Interpretation of insulation resistance and
   polarization index test results
12 Recommended minimum value of polarization
   index and insulation resistance
Annex A (informative) - Variants in polarization index
Annex B (informative) - Direct versus alternating
        voltage testing
Annex C (informative) - Monitoring charge and
        discharge currents
Annex D (informative) - Insulation resistance profiling
        (IRP)
Annex E (informative) - Bibliography

This document describes a recommended procedure for measuring insulation resistance of armature and field windings in rotating machines rated 750 W or greater.

Committee
Electric Machinery
DevelopmentNote
Supersedes IEEE DRAFT 43. (04/2001)
DocumentType
Standard
ISBN
978-0-7381-8937-6
Pages
75
PublisherName
Institute of Electrical & Electronics Engineers
Status
Withdrawn
Supersedes

IEEE 902-1998 IEEE Guide for Maintenance, Operation, and Safety of Industrial and Commercial Power Systems (Yellow Book)
IEEE 1095-2012 REDLINE IEEE Guide for the Installation of Vertical Generators and Generator/Motors for Hydroelectric Applications
CSA C392 : 2011 TESTING OF THREE-PHASE SQUIRREL CAGE INDUCTION MOTORS DURING REFURBISHMENT
CSA C392 : 2011 : INC : UPD 2 : 2012 TESTING OF THREE-PHASE SQUIRREL CAGE INDUCTION MOTORS DURING REFURBISHMENT
IEEE 1068-2015 IEEE Standard for the Repair and Rewinding of AC Electric Motors in the Petroleum, Chemical, and Process Industries
IEEE 3004.8-2016 IEEE Recommended Practice for Motor Protection in Industrial and Commercial Power Systems
IEEE 1665 : 2009 GUIDE FOR THE REWIND OF SYNCHRONOUS GENERATORS, 50 HZ AND 60 HZ, RATED 1 MVA AND ABOVE
NFPA 70B : 2016 RECOMMENDED PRACTICE FOR ELECTRICAL EQUIPMENT MAINTENANCE
IEEE DRAFT 1147 : D8 2005 GUIDE FOR THE REHABILITATION OF HYDROELECTRIC POWER PLANTS
ASME AG-1 : 2019 CODE ON NUCLEAR AIR AND GAS TREATMENT
ASME AG 1 : 2012 CODE ON NUCLEAR AIR AND GAS TREATMENT
IEEE 115-2019 IEEE Guide for Test Procedures for Synchronous Machines Including Acceptance and Performance Testing and Parameter Determination for Dynamic Analysis
IEEE C62.21 : 2003 GUIDE FOR THE APPLICATION OF SURGE VOLTAGE PROTECTIVE EQUIPMENT ON AC ROTATING MACHINERY 1000 V AND GREATER
IEEE DRAFT 1248 : D7 97 DRAFT GUIDE FOR THE COMMISSIONING OF ELECTRICAL SYSTEMS IN HYDROELECTRIC POWER PLANTS
IEEE 334 : 2007 QUALIFYING CONTINUOUS DUTY CLASS 1E MOTORS FOR NUCLEAR POWER GENERATING STATIONS
CSA C392 : 2011 : INC : UPD 1 : 2011 TESTING OF THREE-PHASE SQUIRREL CAGE INDUCTION MOTORS DURING REFURBISHMENT
IEEE DRAFT C50.12 : D10 2004 SALIENT-POLE 50 AND 60 HZ SYNCHRONOUS GENERATORS AND GENERATOR/MOTORS FOR HYDRAULIC TURBINE APPLICATIONS RATED 5 MVA AND ABOVE
S.R. CLC/TS 60034-27:2011 ROTATING ELECTRICAL MACHINES - PART 27: OFF-LINE PARTIAL DISCHARGE MEASUREMENTS ON THE STATOR WINDING INSULATION OF ROTATING ELECTRICAL MACHINES
NETA ATS : 2017 ACCEPTANCE TESTING SPECIFICATIONS FOR ELECTRICAL POWER EQUIPMENT AND SYSTEMS
IEEE DRAFT 434 : D10 2006 FUNCTIONAL EVALUATION OF INSULATION SYSTEMS FOR AC ELECTRIC MACHINES RATED 2300 V AND ABOVE
NEMA ICS 16:2001 Motion/Position Control Motors, Controls and Feedback Devices
NEMA MG 7 : 93 REV 1 96 MOTION/POSITION CONTROL MOTORS AND CONTROLS
IEEE 3006.3-2017 IEEE Recommended Practice for Determining the Impact of Preventative Maintenance on the Reliability of Industrial and Commercial Power Systems
IEEE 1290-2015 IEEE Guide for Motor-Operated Valve (MOV) Motor Application, Protection, Control, and Testing in Nuclear Power-Generating Stations
CSA C392 : 2011 : R2016 TESTING OF THREE-PHASE SQUIRREL CAGE INDUCTION MOTORS DURING REFURBISHMENT
IEEE 95-2002 IEEE Recommended Practice for Insulation Testing of AC Electric Machinery (2300 V and Above) With High Direct Voltage
API STD 541 : 2014 FORM-WOUND SQUIRREL CAGE INDUCTION MOTORS - 375 KW (500 HORSEPOWER) AND LARGER
IEEE C50.13 : 2014 CYLINDRICAL-ROTOR 50 HZ AND 60 HZ, SYNCHRONOUS GENERATORS RATED 10 MVA AND ABOVE
IEEE DRAFT 67 : D5 2005 GUIDE FOR THE OPERATION AND MAINTENANCE OF TURBINE GENERATORS
IEEE 434-2006 IEEE Guide for Functional Evaluation of Insulation Systems for AC Electric Machines Rated 2300 V and Above
API 546 : 2008 BRUSHLESS SYNCHRONOUS MACHINES - 500 KVA AND LARGER
IEEE 252 : 1995 TEST PROCEDURE FOR POLYPHASE INDUCTION MOTORS HAVING LIQUID IN THE MAGNETIC GAP
IEEE 1205-2014 IEEE Guide for Assessing, Monitoring, and Mitigating Aging Effects on Electrical Equipment Used in Nuclear Power Generating Stations and Other Nuclear Facilities
IEEE 115-2009 REDLINE IEEE Guide for Test Procedures for Synchronous Machines Part I—Acceptance and Performance Testing Part II—Test Procedures and Parameter Determination for Dynamic Analysis
CSA C391 : 2015 TESTING OF THREE-PHASE SYNCHRONOUS MACHINES DURING REFURBISHMENT
IEC 60034-27-4:2018 Rotating electrical machines - Part 27-4: Measurement of insulation resistance and polarization index of winding insulation of rotating electrical machines
IEC TS 60034-27:2006 Rotating electrical machines - Part 27: Off-line partial discharge measurements on the stator winding insulation of rotating electrical machines
IEC 60034-27-1:2017 Rotating electrical machines - Part 27-1: Off-line partial discharge measurements on the winding insulation
IEEE 1147-2005 IEEE Guide for the Rehabilitation of Hydroelectric Power Plants
CLC/TS 60034-27:2011 Rotating electrical machines - Part 27: Off-line partial discharge measurements on the stator winding insulation of rotating electrical machines
05/30128254 DC : DRAFT JAN 2005 IEC 60034-27 - ROTATING ELECTRICAL MACHINES - PART 27: PARTIAL DISCHARGE OFF-LINE MEASUREMENTS ON THE STATOR WINDING INSULATION OF ROTATING MACHINERY
DD CLC/TS 60034-27:2011 Rotating electrical machines Off-line partial discharge measurements on the stator winding insulation of rotating electrical machines
IEEE 45.6-2016 IEEE Recommended Practice for Electrical Installations on Shipboard--Electrical Testing
(INACTIVE RECORD)IEEE C50.12 : 2005 SALIENT-POLE 50 HZ AND 60 HZ SYNCHRONOUS GENERATORS AND GENERATOR/MOTORS FOR HYDRAULIC TURBINE APPLICATIONS RATED 5 MVA AND ABOVE
IEEE 2030.2-2015 IEEE Guide for the Interoperability of Energy Storage Systems Integrated with the Electric Power Infrastructure
IEEE 1415 : 2006 INDUCTION MACHINERY MAINTENANCE TESTING AND FAILURE ANALYSIS
IEEE 112-2004 IEEE Standard Test Procedure for Polyphase Induction Motors and Generators
IEEE DRAFT 1068 : D3 JUN 96 RECOMMENDED PRACTICE FOR THE REPAIR AND REWINDING OF MOTORS FOR THE PETROLEUM AND CHEMICAL INDUSTRY
IEEE 841.1-2023 IEEE Standard for Process Industry--International Energy Efficiency Class 3 (IE3) Premium-Efficiency, Severe Duty, Totally Enclosed Frame Surface Cooled Squirrel Cage Induction Motors--0.75 kW to 370 kW (1 hp to 500 hp)
IEEE C50.13-2014 IEEE Standard for Cylindrical-Rotor 50 Hz and 60 Hz Synchronous Generators Rated 10 MVA and Above
IEEE 841-2021 IEEE Standard for Petroleum and Chemical Industry--Premium-Efficiency, Severe-Duty, Totally Enclosed Squirrel Cage Induction Motors from 0.75 kW to 370 kW (1 hp to 500 hp)
IEEE 1812-2014 IEEE Trial-Use Guide for Testing Permanent Magnet Machines
IEEE 522-2023 IEEE Guide for Testing Turn Insulation of Form-Wound Stator Coils for Alternating-Current Electric Machines
IEEE 252-2022 IEEE Standard Test Procedure for Polyphase Induction Motors Having Liquid in the Magnetic Gap
NEMA MG 10012:2023 Safety Standard for Construction and Guide for Selection, Installation and Use of Electric Motors and Generators
IEEE 56-2016 IEEE Guide for Insulation Maintenance of Electric Machines
IEEE 1017.4-2023 IEEE Recommended Practice for Testing and Rating of Electrical Submersible Pump Motors
IEEE 112-2017 IEEE Standard Test Procedure for Polyphase Induction Motors and Generators
IEEE 1812-2023 REDLINE IEEE Guide for Testing Permanent Magnet Machines

IEEE 1-2000 IEEE Recommended Practice - General Principles for Temperature Limits in the Rating of Electrical Equipment and for the Evaluation of Electrical Insulation
NEMA MG 1 : 2016 MOTORS AND GENERATORS
IEEE 67-2005 IEEE Guide for Operation and Maintenance of Turbine Generators
IEEE 62.2-2004 IEEE Guide for Diagnostic Field Testing of Electric Power Apparatus - Electrical Machinery
IEEE 56-1977 IEEE Guide for Insulation Maintenance of Large Alternating-Current Rotating Machinery (10,000 kVA and Larger)
IEEE 510-1983 IEEE Recommended Practices for Safety in High-Voltage and High-Power Testing
IEC 60085:2007 Electrical insulation - Thermal evaluation and designation
IEEE 95-2002 IEEE Recommended Practice for Insulation Testing of AC Electric Machinery (2300 V and Above) With High Direct Voltage

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.