FOREWORD
1 Scope and object
2 Normative references
3 Degrees of severity of service conditions under
condensation and pollution
4 Classification of enclosed switchgear and controlgear
5 Classification procedure
6 Test facilities and associated requirements
6.1 Climatic test room
6.2 Control requirements
6.3 Energizing facilities
7 Selection and arrangement of the equipment for test
7.1 Selection of the equipment
7.2 Arrangement of the equipment
8 Ageing test
8.1 Level 1 ageing test
8.2 Level 2 ageing test
9 Diagnostic procedure after ageing test
9.1 General
9.2 Electrical diagnostic procedure
9.3 Mechanical diagnostic procedure (optional)
9.4 Evaluation
Annex A (normative) Climatic cycle
Annex B (normative) Climatic test room
Annex C (informative) Example of typical environment
IEC/TS 62271-304:2008 applies to indoor enclosed switchgear and controlgear complying with IEC 62271-200 and IEC 62271-201, intended to be used in service conditions more severe with respect to condensation and pollution than the normal service conditions specified in IEC 62271-1. This technical specification covers equipment where any of the insulation is exposed to indoor climatic conditions. This first edition of IEC/TS 62271-304 cancels and replaces the first edition of IEC/TS 60932, published in 1988, and constitutes a technical revision. This revised document has been basically changed to be updated to today's use of high-voltage switchgear and controlgear up to 52 kV.The contents of the corrigendum of January 2010 have been included in this copy.
DevelopmentNote |
Supersedes IEC TR 60932. (05/2008) Stability Date: 2019. (11/2017)
|
DocumentType |
Technical Specification
|
Pages |
32
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NEN NPR CLC IEC/TS 62271-304 : 2009 | Identical |
CLC/TS 62271-304:2008 | Identical |
CEI CLC/TS 62271-304 : 2009 | Identical |
PNE-prEN 62271-304 | Identical |
S.R. CLC/TS 62271-304:2008 | Identical |
BS EN 62625-2:2016 | Identical |
EN 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
EN 62271-201:2014 | High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
EN 60505:2011/AC:2017-03 | EVALUATION AND QUALIFICATION OF ELECTRICAL INSULATION SYSTEMS (IEC 60505:2011/COR1:2017) |
EN 62271-202:2014/AC:2014 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 202: HIGH-VOLTAGE/LOW-VOLTAGE PREFABRICATED SUBSTATION (IEC 62271-202:2014) |
I.S. EN 60505:2011 | EVALUATION AND QUALIFICATION OF ELECTRICAL INSULATION SYSTEMS |
I.S. EN 62271-202:2014 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 202: HIGH-VOLTAGE/LOW-VOLTAGE PREFABRICATED SUBSTATION |
CEI EN 62271-201 : 2015 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 201: AC SOLID-INSULATION ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV |
IEC 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
UNE-EN 62271-200:2012 | High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
12/30253935 DC : DRAFT JUNE 2012 | BS EN 62271-201 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - AC SOLID-INSULATED ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV |
BS EN 62271-1:2017 | High-voltage switchgear and controlgear Common specifications for alternating current switchgear and controlgear |
BS EN 62271-200:2012 | High-voltage switchgear and controlgear AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
EN 62271-200:2012/AC:2015 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV (IEC 62271-200:2011) |
IEC 62271-111:2012 | High-voltage switchgear and controlgear - Part 111: Automatic circuit reclosers and fault interrupters for alternating current systems up to 38 kV |
UNE-EN 62271-202:2015 | High-voltage switchgear and controlgear - Part 202: High-voltage/low-voltage prefabricated substation |
IEEE/IEC C37.60-2012 | IEEE/IEC International Standard - High-voltage switchgear and controlgear - Part 111: Automatic circuit reclosers and fault interrupters for alternating current systems up to 38 kV |
BS EN 60505:2011 | Evaluation and qualification of electrical insulation systems |
IEEE C37.10-2011 REDLINE | IEEE Guide for Investigation, Analysis, and Reporting of Power Circuit Breaker Failures |
UNE-EN 62271-201:2015 | High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
IEC 62271-202:2014 | High-voltage switchgear and controlgear - Part 202: High-voltage/ low-voltage prefabricated substation |
15/30265353 DC : 0 | BS EN 62271-1 ED 2 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: COMMON SPECIFICATIONS FOR ALTERNATING CURRENT SWITCHGEAR AND CONTROLGEAR |
BS EN 62271-201:2014 | High-voltage switchgear and controlgear AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
I.S. EN 62271-200:2012 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: A.C. METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV (IEC 62271-200:2011 (EQV)) |
I.S. EN 62271-1:2017 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: COMMON SPECIFICATIONS FOR ALTERNATING CURRENT SWITCHGEAR AND CONTROLGEAR |
I.S. EN 62271-201:2014 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 201: AC SOLID-INSULATION ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV |
IEC 62271-201:2014 | High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
IEC 62271-200:2011 | High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
BS EN 62271-202:2014 | High-voltage switchgear and controlgear High-voltage/low-voltage prefabricated substation |
IEC 62271-200:2011 | High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
IEC 62271-201:2014 | High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
IEC 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.