IEC TR 80002-3:2014
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Medical device software - Part 3: Process reference model of medical device software life cycle processes (IEC 62304)
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
03-11-2023
English
04-06-2014
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Medical device software life cycle processes
Annex A (informative) - Development of this
technical report
Annex B (informative) - Mapping between IEC 62304:2006
and ISO/IEC 12207:2008
Bibliography
IEC TR 80002-3:2014 which is a technical report (TR), provides the description of software life cycle processes for medical devices. The medical device software life cycle processes are derived from IEC 62304:2006, with corresponding safety classes. They have been aligned with the software development life cycle processes of ISO/IEC 12207:2008 and are presented herein in full compliance with ISO/IEC 24774:2010. The content of these three standards provides the foundation of this TR. This TR does not:
- address areas already covered by existing related standards, e.g. the international standards that relate to the four standards used to build this TR (see Bibliography);
- FDA guidance documents; or
- software development tools. This TR describes the process reference model for medical device software development and is limited in scope to the life cycle processes described in IEC 62304:2006. The process names correspond to those of IEC 62304:2006. The mappings provided in Annex B are essential for the alignment between IEC 62304:2006 (which is based on ISO/IEC 12207:1995) and ISO/IEC 12207:2008, developed to address the detailed normative relationship between the two standards. This technical report is not intended to be used as the basis of regulatory inspection or certification assessment activities.
DevelopmentNote |
Stability date: 2017. (06/2014)
|
DocumentType |
Technical Report
|
Pages |
28
|
PublisherName |
International Electrotechnical Committee
|
Status |
Withdrawn
|
Standards | Relationship |
AAMI/IEC TIR80002-3:2016 | Identical |
NEN NPR IEC/TR 80002-3 : 2014 | Identical |
PD IEC/TR 80002-3:2014 | Identical |
IS/IEC/TR 80002 : Part 3 : 2014 | Identical |
VDI 5702 Blatt 1:2017-04 | Medical device software - Medical SPICE Process assessment model |
ISO/IEC 14764:2006 | Software Engineering — Software Life Cycle Processes — Maintenance |
ISO 13485:2016 | Medical devices Quality management systems Requirements for regulatory purposes |
ISO/IEC 15288:2008 | Systems and software engineering — System life cycle processes |
IEC 62304:2006+AMD1:2015 CSV | Medical device software - Software life cycle processes |
ISO/IEC 12207:2008 | Systems and software engineering — Software life cycle processes |
ISO 14971:2007 | Medical devices Application of risk management to medical devices |
Access your standards online with a subscription