IEC TR 61282-15:2017
Current
The latest, up-to-date edition.
Fibre optic communication system design guides - Part 15: Cable plant and link - Testing multi-fibre optic cable plant terminated with MPO connectors
04-05-2017
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions and abbreviated terms
4 MPO connectors
5 Test methods and measurements
6 Variations of test methods
7 Test configurations
Bibliography
IEC TR 61282-15:2017 provides guidance for the testing of multi-fibre cable, multimode or single-mode, terminated with plugs described in IEC 617547 (all parts) (multiple-fibre push on – MPO). Guidance is provided on the measurement of attenuation, polarity, length and optical return loss. The cabling can be installed in a variety of environments, including residential, commercial, industrial, and data centre premises, and possibly in outside plant environments.
Keywords: attenuation, polarity, length and optical return loss, MPO connectors, multi-fibre cable
DevelopmentNote |
Stability Date: 2021. (05/2017)
|
DocumentType |
Technical Report
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Standards | Relationship |
NEN NPR IEC/TR 61282-15 : 2017 | Identical |
PD IEC/TR 61282-15:2017 | Identical |
I.S. EN IEC 61281-1:2018 | FIBRE OPTIC COMMUNICATION SUBSYSTEMS - PART 1: GENERIC SPECIFICATION |
EN IEC 61281-1:2018 | Fibre optic communication subsystems - Part 1: Generic specification |
BS EN IEC 61281-1:2018 | Fibre optic communication subsystems Generic specification |
IEC 61281-1:2017 | Fibre optic communication subsystems - Part 1: Generic specification |
IEC 61280-4-1:2009 | Fibre-optic communication subsystem test procedures - Part 4-1: Installed cable plant - Multimode attenuation measurement |
IEC 61280-4-2:2014 | Fibre-optic communication subsystem test procedures - Part 4-2: Installed cable plant - Single-mode attenuation and optical return loss measurement |
IEC 61300-3-35:2015 RLV | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-35: Examinations and measurements - Visual inspection of fibre optic connectors and fibre-stub transceivers |
IEC 61754-7-1:2014 | Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 7-1: Type MPO connector family - One fibre row |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.