IEC 61223-3-3:1996

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Evaluation and routine testing in medical imaging departments -Part 3-3: Acceptance tests - Imaging performance of X-ray equipmentfor digital subtraction angiography (DSA)

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Withdrawn date

31-12-2021

Language(s)

English - French, Spanish, Castilian

Published date

08-11-1996

£102.31
Excluding VAT

FOREWORD
INTRODUCTION
Clause
1 Scope and object
   1.1 Scope
   1.2 Object
2 Normative references
3 Terminology
   3.1 Degree of requirements
   3.2 Use of terms
   3.3 Defined terms
4 General aspects of ACCEPTANCE TESTS
   4.1 General conditions to be considered in test
        procedures
   4.2 Documents and data for the tests
   4.3 Test conditions
   4.4 Test parameters
   4.5 Test equipment including PHANTOMS and TEST DEVICES
   4.6 Evaluating the test results
5 Test methods for mammographic X-RAY EQUIPMENT
   5.1 Identification
   5.2 Check of documents
   5.3 Decision on representative DSA operation modes
   5.4 Visual and functional tests
   5.5 AIR KERMA measurements
   5.6 DYNAMIC RANGE
   5.7 DSA CONTRAST SENSITIVITY
   5.8 DSA VISUAL SPATIAL RESOLUTION
   5.9 ARTIFACTS
   5.10 Compensation for ATTENUATION non-linearity (optional)
6 Test report and statement of compliance
Annexes
A Terminology - Index of defined terms
B Example of a DSA PHANTOM without test step for
   compensation
C Example of a DSA PHANTOM with test step for compensation

Applies to those components of X-ray equipment which influence theimage quality of equipment for digital subtraction angiography(DSA) with an imaging system consisting of an X-ray generationsubsystem, a detection device comprising an X-ray image intensifiertelevision chain, means of digitization and digital imageprocessing, image storage and image manipulation includingsubtraction, and facilities for image display.Defines the essential parameters which describe the performance ofthe above-mentioned components of X-ray equipment with regard toimaging properties, and defines methods of testing whether measuredquantities related to those parameters comply with specifiedtolerances.

DevelopmentNote
Also numbered as BS EN 61223-3.3 and BS 7725-3.3(1997) (11/2005)
DocumentType
Standard
Pages
39
PublisherName
International Electrotechnical Committee
Status
Withdrawn

BS EN 61223-3-2:2008 Evaluation and routine testing in medical imaging departments Acceptance tests. Imaging performance of mammographic X-ray equipment
IEC TR 60788:2004 Medical electrical equipment - Glossary of defined terms
I.S. EN 61223-3-2:2008 EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 3-2: ACCEPTANCE TESTS - IMAGING PERFORMANCE OF MAMMOGRAPHIC X-RAY EQUIPMENT
IEC 61223-3-2:2007 Evaluation and routine testing in medical imaging departments - Part 3-2: Acceptance tests - Imaging performance of mammographic X-ray equipment
PD IEC TR 60788:2004 Medical electrical equipment. Glossary of defined terms
EN 61223-3-2:2008 Evaluation and routine testing in medical imaging departments - Part 3-2: Acceptance tests - Imaging performance of mammographic X-ray equipment

IEC 60601-2-7:1998 Medical electrical equipment - Part 2-7: Particular requirements for the safety of high-voltage generators of diagnostic X-ray generators
IEC 60417N:1995 Thirteenth supplement
IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
IEC TR 60788:2004 Medical electrical equipment - Glossary of defined terms
ISO 2092:1981 Light metals and their alloys Code of designation based on chemical symbols
IEC 60601-1-3:2008+AMD1:2013 CSV Medical electrical equipment - Part 1-3: General requirements forbasic safety and essential performance - Collateral Standard: Radiation protection in diagnostic X-ray equipment
IEC 61223-2-4:1994 Evaluation and routine testing in medical imaging departments - Part 2-4: Constancy tests - Hard copy cameras
IEC 61223-2-5:1994 Evaluation and routine testing in medical imaging departments - Part 2-5: Constancy tests - Image display devices

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.