IEC 61219:1993
Current
The latest, up-to-date edition.
Live working - Earthing or earthing and short-circuiting equipment using lances as a short-circuiting device - Lance earthing
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
15-10-1993
Foreword
1. Scope
2. Normative references
3. Definitions
3.1 Tests
3.2 Special terms
4. Electrical characteristics
5. Requirements
5.1 General
5.2 Earthing cables
5.3 Lances, lance contacts and guiding components
5.4 Insulation co-ordination with assemblies
5.5 Co-ordination with assembly enclosure
5.6 Marking
5.7 Manufacturer's instructions for use
6. Tests
6.1 General
6.2 Lance insertion and removal test
6.3 Test on reliability of stops and ability of lances,
couplings, handles and stops to withstand connecting
forces
6.4 Short-circuit current tests
6.5 Dielectric tests
6.6 Testing durability of marking
Figures
1 Illustrations of multi-phase earthing and short-circuiting
with one single lance
2 Illustration of multiple lance
3 Illustrations of multi-phase lance earthings with a set
of single lances
4 Illustrations of single-phase lance earthings
5 Typical test set-up for multi-phase lance earthings with
one single lance (used for voltages less than or equal to
36 kV)
6 Insulating handle and its preparation for voltage test
7 Typical test set-up for lance earthings with voltages
more than 36 kV
Tables
1 Special temperature categories
2 List of tests referred to subclauses and test categories
3 Peak current factor
Annexes
A Sampling procedure
B Short-circuit testing in a standardized test set-up of
multi-phase devices using a set of single lances
C Selection, use and maintenance of lance earthings
Applies to equipment for temporary earthing or earthing and short-circuiting of electrically isolated parts of a.c. installations, the disconnection of which has been verified, for the protection of workers while work is in progress using lance(s) as the earthing or earthing and short-circuiting device. Specifies the perfomance and safety requirements and tests for lance devices with matching fixed contacts, guiding arrangements, enclosure, insulating elements and earthing cables, if any. For devices containing short-circuiting cables see IEC 61230. The contents of the corrigendum of May 2000 have been included in this copy.
DevelopmentNote |
Stability Date: 2017. (10/2012)
|
DocumentType |
Standard
|
Pages |
65
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Standards | Relationship |
NF EN 61219 : 1994 | Identical |
NEN EN IEC 61219 : 1994 C1 2000 | Identical |
NEN 11219 : 1994 | Identical |
I.S. EN 61219:1994 | Identical |
PN EN 61219 : 1997 | Identical |
SN EN 61219 : 1993 | Identical |
VDE 0683-200 : 1995 | Identical |
DIN EN 61219 : 1995 | Identical |
BIS IS 14981 : 2001(R2016) | Identical |
BS EN 61219:1994 | Identical |
UNE-EN 61219:1998 | Identical |
CEI EN 61219 : 1996 | Identical |
EN 61219:1993 | Identical |
UNE-EN 61219:1993 | Identical |
CEI 18-66 : 2013 | ELECTRICAL INSTALLATIONS IN SHIPS - PART 509: OPERATION OF ELECTRICAL INSTALLATIONS |
07/30162245 DC : 0 | BS EN 60092-XXX - ELECTRICAL INSTALLATIONS IN SHIPS - PART XXX - OPERATION OF ELECTRICAL INSTALLATIONS |
I.S. EN 50110-1:2013 | OPERATION OF ELECTRICAL INSTALLATIONS - PART 1: GENERAL REQUIREMENTS |
EN 50191:2010 | ERECTION AND OPERATION OF ELECTRICAL TEST EQUIPMENT |
UNE-EN 50122-1:2011 | Railway applications - Fixed installations - Electrical safety, earthing and the return circuit -- Part 1: Protective provisions against electric shock |
IEC 60092-509:2011 | Electrical installations in ships - Part 509: Operation of electrical installations |
I.S. EN 50122-1:2011 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRICAL SAFETY, EARTHING AND THE RETURN CIRCUIT - PART 1: PROTECTIVE PROVISIONS AGAINST ELECTRIC SHOCK |
CSA C22.3 No. 61936-1 : 2008 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES |
CLC/TR 50488:2006 | Railway applications - Safety measures for the personnel working on or near overhead contact lines |
IEC 61936-1:2010+AMD1:2014 CSV | Power installations exceeding 1 kV a.c. - Part 1: Common rules |
CEI EN 50110-1 : 2014 | OPERATION OF ELECTRICAL INSTALLATIONS - PART 1: GENERAL REQUIREMENTS |
08/30191891 DC : DRAFT OCT 2008 | BS EN 61936-1 - POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES |
08/30181631 DC : DRAFT APR 2008 | BS IEC 60092-509 - ELECTRICAL INSTALLATIONS IN SHIPS - PART 509: OPERATION OF ELECTRICAL INSTALLATIONS |
IEC 62128-1:2013 | Railway applications - Fixed installations - Electrical safety, earthing and the return circuit - Part 1: Protective provisions against electric shock |
CSA C22.3 No. 61936-1 : 2008 : R2015 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES |
EN 61936-1 : 2010 AMD 1 2014 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES (IEC 61936-1:2010/A1:2014) |
I.S. EN 50191:2010 | ERECTION AND OPERATION OF ELECTRICAL TEST EQUIPMENT |
CEI CLC/TR 50488 : 2007 | RAILWAY APPLICATIONS - SAFETY MEASURES FOR PERSONNEL WORKING NEAR OVERHEAD CONTACT LINES |
UNE-EN 50110-1:2014 | Operation of electrical installations - Part 1: General requirements |
S.R. CLC TR 50488:2007 | RAILWAY APPLICATIONS - SAFETY MEASURES FOR THE PERSONNEL WORKING ON OR NEAR OVERHEAD CONTACT LINES |
I.S. EN 61936-1:2010 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES |
08/30160532 DC : DRAFT MAY 2008 | BS EN 50122-1 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRICAL SAFETY, EARTHING AND BONDING - PART 1: PROTECTIVE PROVISIONS AGAINST ELECTRIC SHOCK |
BS EN 61936-1 : 2010 | POWER INSTALLATIONS EXCEEDING 1 KV A.C - PART 1: COMMON RULES |
UNE-EN 61936-1:2012 | Power installations exceeding 1 kV a.c. -- Part 1: Common rules |
09/30205281 DC : 0 | BS EN 50191 - ERECTION AND OPERATION OF ELECTRICAL TEST EQUIPMENT |
BS EN 50122-1 : 2011 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRICAL SAFETY, EARTHING AND THE RETURN CIRCUIT - PART 1: PROTECTIVE PROVISIONS AGAINST ELECTRIC SHOCK |
BS IEC 60092-509:2011 | Electrical installations in ships Operation of electrical installations |
BS EN 50191:2010 | Erection and operation of electrical test equipment |
BS EN 50110-1:2013 | Operation of electrical installations General requirements |
12/30251569 DC | BS IEC 62128-1. Railway applications. Fixed installations. Electrical safety, earthing and the return circuit. Part 1. Protective provisions against electric shock |
EN 50110-1:2013 | Operation of electrical installations - Part 1: General requirements |
EN 50122-1:2011/A4:2017 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRICAL SAFETY, EARTHING AND THE RETURN CIRCUIT - PART 1: PROTECTIVE PROVISIONS AGAINST ELECTRIC SHOCK |
IEC TS 60479-1:2005+AMD1:2016 CSV | Effects of current on human beings and livestock - Part 1: Generalaspects |
IEC 61138:2007 | Cables for portable earthing and short-circuiting equipment |
IEC 60855:1985 | Insulating foam-filled tubes and solid rods for live working |
IEC 61235:1993 | Live working - Insulating hollow tubes for electrical purposes |
IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
IEC 60410:1973 | Sampling plans and procedures for inspection by attributes |
IEC 60439-1:1999+AMD1:2004 CSV | Low-voltage switchgear and controlgear assemblies - Part 1: Type-tested and partially type-tested assemblies |
IEC 61230:2008 | Live working - Portable equipment for earthing or earthing and short-circuiting |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60298:1990 | A.C. metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.