IEC 61037:1990+AMD1:1996+AMD2:1998 CSV
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Electricity metering - Tariff and load control - Particular requirements for electronic ripple control receivers
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
17-05-2004
English - French
12-08-1998
FOREWORD
INTRODUCTION
Clause
1 Scope
2 Normative references
3 Definitions
4 Requirements
5 Tests and test conditions
Annexes (normative)
A Relationship between ambient air temperature and
relative humidity
B Reference and limiting values of the influence
quantities
C Electromagnet for testing the influence of
externally-produced magnetic fields
D Harmonic levels
E Selection of frequency for tests with harmonics
F Combination of parameters for operation and
non-operation tests
Annexes (informative)
G Acceptance tests
H Code terms
J Example of a test configuration
K Values of the influence quantities for the different
tests
Tables
Specifies requirements for the type test of indoor self-contained static ripple control receivers for the reception and interpretation of pulses of a single audio frequency superimposed on the voltage of the electricity distribution network and for the execution of the corresponding switching operations.Requirements for constructional details internal to the receivers are not specified.
DocumentType |
Standard
|
Pages |
83
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NF EN 61037 : 93 AMD 2 1998 | Identical |
GOST IEC 61037 : 2011 | Identical |
NBN EN 61037 : 93 AMD 2 98 | Similar to |
NEN EN IEC 61037 : 92 AMD 2 1998 | Identical |
NEN 11037 : 93 AMD 1 1996 | Similar to |
I.S. EN 61037:1993 | Identical |
SN EN 61037 : 1992 AMD 2 1998 | Identical |
VDE 0420-1 : 94 AMD 2 99 | Identical |
BS EN 61037:1993 | Identical |
CEI EN 61037 : 1998 AMD 2 1999 | Identical |
EN 61037:1992/A2:1998 | Identical |
BS 7401(1990) : 1990 AMD 7673 | Identical |
GOST R IEC 61037 : 2001 | Identical |
BS EN 61000-2-12:2003 | Electromagnetic compatibility (EMC). Environment Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems |
I.S. EN 61000-2-12:2003 | ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC MEDIUM-VOLTAGE POWER SUPPLY SYSTEMS |
EN 61000-2-12:2003 | Electromagnetic compatibility (EMC) - Part 2-12: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems |
EN 61000-2-2:2002/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS (IEC 61000-2-2:2002/A1:2017) |
BS EN 61000-2-2 : 2002 | ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS |
CEI EN 61000-2-12 : 2004 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-12: ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC MEDIUM-VOLTAGE POWER SUPPLY SYSTEMS |
IEC 61000-2-2:2002+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems |
IEC 61000-2-12:2003 | Electromagnetic compatibility (EMC) - Part 2-12: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems |
CSA C61000.2.2 : 2004 : R2014 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-2: ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS |
CSA C61000.2.2 : 2004 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-2: ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS |
CSA C61000.2.12 : 2004 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-12: ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC MEDIUM-VOLTAGE POWER SUPPLY SYSTEMS |
CSA C61000.2.12 : 2004 : R2014 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-12: ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC MEDIUM-VOLTAGE POWER SUPPLY SYSTEMS |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) |
IEC 60817:1984 | Spring-operated impact-test apparatus and its calibration |
CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
IEC 60410:1973 | Sampling plans and procedures for inspection by attributes |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60269-3:2010+AMD1:2013 CSV | Low-voltage fuses - Part 3: Supplementary requirements for fuses foruse by unskilled persons (fuses mainly for household or similar applications) - Examples of standardized systems of fuses A to F |
IEC 60417-2:1998 | Graphical symbols for use on equipment - Part 2: Symbol originals |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV | Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |