IEC 61034-2:2005+AMD1:2013 CSV
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Measurement of smoke density of cables burning under definedconditions - Part 2: Test procedure and requirements
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
26-11-2019
English - French
27-06-2013
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Test apparatus
5 Test assembly
6 Test procedure
7 Evaluation of test results
8 Retest procedure
9 Test report
Annex A (informative) - Guidance on the principles
and use of smoke measurements
Annex B (informative) - Recommended performance
requirement
Bibliography
IEC 61034-2:2005+A1:2013 Provides details of the test procedure to be employed for the measurement of the density of smoke emitted from cables burning under defined conditions. It describes the means of preparing and assembling cables for test, the method of burning the cables, and gives recommended requirements for evaluating test results. The principal changes with respect to the previous edition are as follows:
a) inclusion of cables down to 1 mm diameter;
b) inclusion of non-circular cables;
c) addition of guidance on testing cables above 80 mm diameter;
d) delineation of elements of the test report;
e) addition of guidance on the calculation for other parameters for fire safety engineering purposes;
f) removal of minor differences with equivalent CENELEC work to allow parallel voting with that body. Has the status of a group safety publication in accordance with IEC Guide 104. This consolidated version consists of the third edition (2005) and its amendment 1 (2013). Therefore, no need to order amendment in addition to this publication.
Committee |
TC 20
|
DevelopmentNote |
Stability Date: 2018. (10/2012)
|
DocumentType |
Standard
|
Pages |
32
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
OVE/ONORM EN 61034-2 : 2014 | Identical |
UNE-EN 61034-2:2005 | Identical |
GOST IEC 61034-2 : 2011 ERRATA 2015 | Identical |
NEN EN IEC 61034-2 : 2006 AMD 1 2013 | Identical |
I.S. EN 61034-2:2005 | Identical |
AS/NZS IEC 61034.2:2017 | Identical |
PN EN 61034-2 : 2010 AMD 1 2014 | Identical |
DIN EN 61034-2 : 2014 | Identical |
VDE 0482-1034-2 : 2014 | Identical |
BS EN 61034-2 : 2005 | Identical |
CEI 20-37/5 : 2ED 1997 | Identical |
EN 61034-2:2005/A1:2013 | Identical |
NF EN 61034-2 : 2005 AMD 1 2013 | Identical |
SAC GB/T 17651.2 : 1998 | Identical |
UNE 21172-2:1993 | Identical |
CEI 18-49 : 2013 | ELECTRICAL INSTALLATIONS IN SHIPS - PART 350: GENERAL CONSTRUCTION AND TEST METHODS OF POWER, CONTROL AND INSTRUMENTATION CABLES FOR SHIPBOARD AND OFFSHORE APPLICATIONS |
BS EN 50411-3-8:2016 | Fibre organizers and closures to be used in optical fibre communication systems. Product specifications Fibre management system, terminal equipment box type 1 for category C |
IEC 62930:2017 | Electric cables for photovoltaic systems with a voltage rating of 1,5 kV DC |
BS EN 50382-2 : 2008 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C |
BS EN 50525-3-41:2011 | Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke |
12/30211334 DC : 0 | BS ISO 15791-1 - PLASTICS - DEVELOPMENT AND USE OF INTERMEDIATE-SCALE FIRE TESTS FOR PLASTICS PRODUCTS - PART 1: GENERAL GUIDANCE (ISO/DIS 15791-1:2012) |
UNE-EN 50525-3-11:2012 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 3-11: Cables with special fire performance - Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke |
07/30164222 DC : 0 | BS EN 60794-2-20 - OPTICAL FIBRE CABLES - PART 2-20: INDOOR OPTICAL FIBRE CABLES - FAMILY SPECIFICATION FOR MULTI-FIBRE OPTICAL DISTRIBUTION CABLES |
CEI EN 50143 : 2012 | CABLES FOR SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1000 V BUT NOT EXCEEDING 10000 V |
I.S. EN 62012-1:2002 | MULTICORE AND SYMMETRICAL PAIR/QUAD CABLES FOR DIGITAL COMMUNICATIONS TO BE USED IN HARSH ENVIRONMENTS - PART 1: GENERIC SPECIFICATION |
BS EN 50143:2009 | Cables for signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1000 V but not exceeding 10000 V |
08/30188833 DC : 0 | BS EN 50525-3-11 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-11: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE |
06/30151267 DC : 0 | BS ISO CD 10840 - PLASTICS - GUIDANCE FOR THE USE OF STANDARD FIRE TESTS |
08/30188839 DC : 0 | BS EN 50525-3-31 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-31: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE |
BS EN 50264-2-2:2008 | Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation. Multicore cables |
17/30309558 DC : 0 | BS IEC 60772 ED 2.0 - NUCLEAR POWER PLANTS - INSTRUMENTATION SYSTEMS IMPORTANT TO SAFETY - ELECTRICAL PENETRATION ASSEMBLIES IN CONTAINMENT STRUCTURES |
09/30166429 DC : 0 | BS 8492 - TELECOMMUNICATIONS EQUIPMENT AND TELECOMMUNICATIONS CABLING - CODE OF PRACTICE FOR FIRE PERFORMANCE AND PROTECTION |
08/30188842 DC : 0 | BS EN 50525-3-41 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-41: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE CROSS LINKED INSULATION, AND LOW EMISSION OF SMOKE |
KTA 2101.3 : 2015(R2017) | FIRE PROTECTION IN NUCLEAR POWER PLANTS - PART 3: FIRE PROTECTION OF MECHANICAL AND ELECTRICAL PLANT COMPONENTS |
IEC 60092-376:2017 | Electrical installations in ships - Part 376: Cables for control and instrumentation circuits 150/250 V (300 V) |
S.R. HD 60364-4-42:2011 | LOW VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-42: PROTECTION FOR SAFETY - PROTECTION AGAINST THERMAL EFFECTS |
S.R. CLC/TS 50576:2016 | ELECTRIC CABLES - EXTENDED APPLICATION OF TEST RESULTS FOR REACTION TO FIRE |
I.S. EN 50264-3-2:2008 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - MULTICORE CABLES |
I.S. EN 50618:2014 | ELECTRIC CABLES FOR PHOTOVOLTAIC SYSTEMS |
IEC 60092-352:2005 | Electrical installations in ships - Part 352: Choice and installation of electrical cables |
BS EN 50575 : 2014 | POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS |
I.S. EN 50264-3-1:2008 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - SINGLE CORE CABLES |
CEI EN 50525-3-11 : 2012 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-11: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE |
NFC 32 102-13 : 2007 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 13: HALOGEN-FREE FLEXIBLE CABLES HAVING LOW EMISSION OF SMOKE |
NF EN 50143 : 2009 | CABLES FOR SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1000 V BUT NOT EXCEEDING 10000 V |
03/318326 DC : DRAFT NOV 2003 | |
BS EN ISO 15791-1:2013 | Plastics. Development and use of intermediate-scale fire tests for plastics products General guidance |
EN 50264-2-1:2008 | Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables |
EN 50411-3-5:2015 | Fibre organisers and closures to be used in optical fibre communication systems - Product specifications - Part 3-5: Wall outlet |
HD 620 : 2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV |
EN 187103:2003 | Family specification - Optical fibre cables for indoor applications |
EN 50575:2014/A1:2016 | POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS |
EN 50525-3-11:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-11: Cables with special fire performance - Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke |
EN 50411-3-8:2016 | Fibre organizers and closures to be used in optical fibre communication systems - Product specifications - Part 3-8: Fibre management system, terminal equipment box type 1 for category C |
HD 60364-4-42 : 2011 AMD 1 2015 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-42: PROTECTION FOR SAFETY - PROTECTION AGAINST THERMAL EFFECTS (IEC 60364-4-42:2010/A1:2014) |
EN 60702-1:2002/A1:2015 | MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES (IEC 60702-1:2002/A1:2015) |
CEI 18-64 : 2008 | MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 4: CABLES |
EN 50382-1 : 2008 AMD 1 2013 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS |
EN 50264-1:2008 | Railway applications - Railway rolling stock power and control cables having special fire performance - Part 1: General requirements |
EN 50525-3-31:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-31: Cables with special fire performance - Single core non-sheathed cables with halogen-free thermoplastic insulation, and low emission of smoke |
HD 22.13 : 200S2 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 13: HALOGEN-FREE FLEXIBLE CABLES HAVING LOW EMISSION OF SMOKE |
EN 50264-3-2:2008 | Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables |
BS IEC 61196-9:2014 | Coaxial communication cables Sectional specification for RF flexible cables |
I.S. EN 60702-1:2002 | MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES |
I.S. EN 50575:2014 | POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS |
UNE-EN 50264-3-2:2010 | Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables |
BS EN 50525-3-31:2011 | Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Single core non-sheathed cables with halogen-free thermoplastic insulation, and low emission of smoke |
ISO 10840:2008 | Plastics — Guidance for the use of standard fire tests |
BS EN 50525-3-11:2011 | Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke |
IEC 61196-9:2014 | Coaxial communication cables - Part 9: Sectional specification for RF flexible cables |
BS ISO 10840:2008 | Plastics. Guidance for the use of standard fire tests |
07/30164159 DC : 0 | BS EN 60794-2-30 - OPTICAL FIBRE CABLES - PART 2-30: INDOOR OPTICAL FIBRE CABLES - FAMILY SPECIFICATION FOR OPTICAL FIBRE RIBBON CABLES |
HD 605 S2:2008/corrigendum:2010 | ELECTRIC CABLES - ADDITIONAL TEST METHODS |
BS EN 50264-2-1:2008 | Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation. Single core cables |
CEI EN 50551-2 : 2014 | SIMPLEX AND DUPLEX CABLES TO BE USED FOR CORDS - PART 2: DETAILED SPECIFICATION AND MINIMUM REQUIREMENTS FOR A 3,0 MM SIMPLEX RUGGEDISED SINGLE MODE FIBRE CABLE TO BE USED FOR PATCHCORDS/CORDS CATEGORY U |
CEI EN 50525-3-31 : 2012 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-31: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE |
I.S. HD 60364-4-42:2011 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-42: PROTECTION FOR SAFETY - PROTECTION AGAINST THERMAL EFFECTS |
I.S. EN 50411-3-5:2015 | FIBRE ORGANISERS AND CLOSURES TO BE USED IN OPTICAL FIBRE COMMUNICATION SYSTEMS - PRODUCT SPECIFICATIONS - PART 3-5: WALL OUTLET |
I.S. HD 22.9:2007 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 9: SINGLE CORE HALOGEN-FREE NON-SHEATHED CABLES FOR FIXED WIRING HAVING LOW EMISSION OF SMOKE |
I.S. EN 50264-2-1:2008 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES |
CEI CLC/TS 50576 : 2015 | ELECTRIC CABLES - EXTENDED APPLICATION OF TEST RESULTS FOR REACTION TO FIRE |
IEC TS 60695-6-2:2005 | Fire hazard testing - Part 6-2: Smoke obscuration - Summary and relevance of test methods |
UNE-IEC 60092-350:2015 | Electrical installations in ships - Part 350: General construction and test methods of power, control and instrumentation cables for shipboard and offshore applications |
BS EN 60695-6-1 : 2005 | FIRE HAZARD TESTING - PART 6-1: SMOKE OBSCURATION - GENERAL GUIDANCE |
I.S. EN 50525-3-31:2011 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-31: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE |
I.S. EN 50525-3-41:2011 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-41: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE |
EN 13501-6:2014 | Fire classification of construction products and building elements - Part 6: Classification using data from reaction to fire tests on electric cables |
UNE-CLC/TS 50576:2017 | Electric cables - Extended application of test results for reaction to fire |
NF EN 50264-3-1 : 2008 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - SINGLE CORE CABLES |
UNE-EN 50525-3-21:2012 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 3-21: Cables with special fire performance - Flexible cables with halogen-free crosslinked insulation, and low emission of smoke |
PREN 50575 : DRAFT 2012 | POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS |
NF EN 60794-1-1 : 2002 | OPTICAL FIBER CABLES - PART 1-1: GENERIC SPECIFICATION - GENERAL |
S.R. CEN/TS 45545-2:2009 | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAVIOUR OF MATERIALS AND COMPONENTS |
EN 60695-6-1:2005/A1:2010 | FIRE HAZARD TESTING - PART 6-1: SMOKE OBSCURATION - GENERAL GUIDANCE |
IEC 60092-354:2014 | Electrical installations in ships - Part 354: Single- and three-core power cables with extruded solid insulation for rated voltages 6 kV (U<sub>m</sub> = 7,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV) |
IEC 60092-353:2016 | Electrical installations in ships - Part 353: Power cables for rated voltages 1 kV and 3 kV |
IEC PAS 60794-2-50:2004 | Optical fibre cables - Part 2-50: Indoor optical fibre cables - Family specification for simplex and duplex cables for use in patch cords |
CEI EN 60695-6-2 : 2013 | FIRE HAZARD TESTING - PART 6-2: SMOKE OBSCURATION - SUMMARY AND RELEVANCE OF TEST METHODS |
IEC 60092-376:2017 RLV | Electrical installations in ships - Part 376: Cables for control and instrumentation circuits 150/250 V (300 V) |
PD IEC/TR 62222:2012 | Fire performance of communication cables installed in buildings |
I.S. EN ISO 15791-1:2013 | PLASTICS - DEVELOPMENT AND USE OF INTERMEDIATE-SCALE FIRE TESTS FOR PLASTICS PRODUCTS - PART 1: GENERAL GUIDANCE (ISO 15791-1:2014) |
12/30273098 DC : 0 | BS EN 60702-1:2002+A1 - MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES |
PREN 50525-3-11 : DRAFT 2008 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-11: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE |
UNE-EN 50618:2015 | Electric cables for photovoltaic systems |
10/30216687 DC : 0 | BS EN 45545-2 - RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAVIOUR OF MATERIALS AND COMPONENTS |
BS EN 50382-1 : 2008 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS |
BS EN 50264-1:2008 | Railway applications. Railway rolling stock power and control cables having special fire performance General requirements |
BS EN 50618:2014 | Electric cables for photovoltaic systems (BT(DE/NOT)258) |
17/30348256 DC : 0 | BS EN 13501-6 - FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 6: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS ON ELECTRIC CABLES |
IEC 62821-1:2015 | Electric cables - Halogen-free, low smoke, thermoplastic insulated and sheathed cables of rated voltages up to and including 450/750 V - Part 1: General requirements |
BS IEC 61892-3:2012 | Mobile and fixed offshore units. Electrical installations Equipment |
BS ISO/TR 11696-2:1999 | Uses of reaction to fire test results Fire hazard assessment of construction products |
BS EN 62012-1:2002 | Multicore and symmetrical pair/quad cables for digital communications to be used in harsh environments Generic specification |
BS EN 50525-3-21:2011 | Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Flexible cables with halogen-free crosslinked insulation, and low emission of smoke |
CEI EN 50264-2-1 : 2009 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES |
CEI EN 50525-3-41 : 2012 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-41: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE |
BS EN 50264-3-2:2008 | Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation with reduced dimensions. Multicore cables |
NF EN 187103 : 2003 | FAMILY SPECIFICATION - OPTICAL FIBRE CABLES FOR INDOOR APPLICATIONS |
UNE-IEC 60092-353:2017 | Electrical installations in ships - Part 353: Power cables for rated voltages 1 kV and 3 kV |
CEI EN 50264-2-2 : 2009 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - MULTICORE CABLES |
05/30131385 DC : DRAFT MAR 2005 | IEC 61156-1 ED 3 - MULTICORE AND SYMMETRICAL PAIR/QUAD CABLES FOR DIGITAL COMMUNICATIONS - PART 1: GENERIC SPECIFICATION |
UNE-EN 50264-2-1:2010 | Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables |
NFC 32 102-9 : 2007 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 9: SINGLE CORE HALOGEN-FREE NON-SHEATHED CABLES FOR FIXED WIRING HAVING LOW EMISSION OF SMOKE |
I.S. EN 50551-2:2013 | SIMPLEX AND DUPLEX CABLES TO BE USED FOR CORDS - PART 2: DETAILED SPECIFICATION AND MINIMUM REQUIREMENTS FOR A 3,0 MM SIMPLEX RUGGEDISED SINGLE MODE FIBRE CABLE TO BE USED FOR PATCHCORDS/CORDS CATEGORY U |
I.S. EN 50382-1:2008 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS |
BS EN 13501-6:2014 | Fire classification of construction products and building elements Classification using data from reaction to fire tests on electric cables |
IEC TR 60092-370:2009 | Electrical installations in ships - Part 370: Guidance on the selection of cables for telecommunication and data transfer including radio-frequency cables |
BS EN 60702-1 : 2002 | MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES |
PREN 13501-6 : DRAFT 2017 | FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 6: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS ON ELECTRIC CABLES |
UNI EN 13501-6 : 2014 | FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 6: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS ON ELECTRIC CABLES |
CEI EN 50264-3-2 : 2009 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - MULTICORE CABLES |
I.S. EN 13501-6:2014 | FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 6: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS ON ELECTRIC CABLES |
I.S. EN 60695-6-2:2011 | FIRE HAZARD TESTING - PART 6-2: SMOKE OBSCURATION - SUMMARY AND RELEVANCE OF TEST METHODS (IEC 60695-6-2:2011) |
NF EN 50382-2 : 2008 AMD 1 2013 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C |
ISO/TR 10840:1993 | Plastics Burning behaviour Guidance for development and use of fire tests |
IEC 61196-4:2015 | Coaxial communication cables - Part 4: Sectional specification for radiating cables |
IEC 61892-3:2012 | Mobile and fixed offshore units - Electrical installations - Part 3: Equipment |
IEC 60695-6-2:2011 | Fire hazard testing - Part 6-2: Smoke obscuration - Summary and relevance of test methods |
IEC 60092-353:2016 RLV | Electrical installations in ships - Part 353: Power cables for rated voltages 1 kV and 3 kV |
UNE-HD 620-9E:2012 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 9: HEPR insulated single core cables, and single core pre-assembled cables. Section E: Cables with polyolefine compound sheath (types 9E-1, 9E-3, 9E-4 and 9E-5). |
EN ISO 15791-1:2013 | Plastics - Development and use of intermediate-scale fire tests for plastics products - Part 1: General guidance (ISO 15791-1:2014) |
UNI EN ISO 15791-1 : 2014 | PLASTICS - DEVELOPMENT AND USE OF INTERMEDIATE-SCALE FIRE TESTS FOR PLASTICS PRODUCTS - PART 1: GENERAL GUIDANCE |
UNE-EN 50264-1:2010 | Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 1: General requirements |
EA 0052:2014 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV. HPTR insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1, type 2 and type 3). |
UNE-EN 50264-3-1:2010 | Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables |
BS EN 50264-3-1:2008 | Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation with reduced dimensions. Single core cables |
CEI EN 50264-3-1 : 2009 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - SINGLE CORE CABLES |
CEI EN 62012-1 : 2003 | MULTICORE AND SYMMETRICAL PAIR/QUAD CABLES FOR DIGITAL COMMUNICATIONS TO BE USED IN HARSH ENVIRONMENT - PART 1: GENERIC SPECIFICATION |
UNI CEI CEN/TS 45545-2 : 2009 | RAILWAY APPLICATIONS - FIRE PROTECTION OF RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAVIOUR OF MATERIALS AND COMPONENTS |
12/30259025 DC : 0 | BS EN 50575 - POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS |
CEI EN 50264-1 : 2009 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS |
BS ISO 15791-1 : 2002 AMD 15256 | PLASTICS - DEVELOPMENT AND USE OF INTERMEDIATE-SCALE FIRE TESTS FOR PLASTICS PRODUCTS - PART 1: GENERAL GUIDANCE |
I.S. EN 60695-6-1:2005 | FIRE HAZARD TESTING - PART 6-1: SMOKE OBSCURATION - GENERAL GUIDANCE |
DD CEN/TS 45545-2:2009 | Railway applications. Fire protection on railway vehicles Requirements for fire behaviour of materials and components |
CEI EN 50525-3-21 : 2012 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE |
I.S. EN 50382-2:2008 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C |
I.S. EN 50525-3-11:2011 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-11: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE |
NF EN 50264-2-2 : 2008 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - MULTICORE CABLES |
I.S. EN 187103:2003 | FAMILY SPECIFICATION - OPTICAL FIBRE CABLES FOR INDOOR APPLICATIONS |
UNE-EN 60695-6-2:2012 | Fire hazard testing - Part 6-2: Smoke obscuration - Summary and relevance of test methods |
UNE-IEC 60092-376:2017 | Electrical installations in ships - Part 376: Cables for control and instrumentation circuits 150/250 V (300 V) |
IEC 60092-350:2014 | Electrical installations in ships - Part 350: General construction and test methods of power, control and instrumentation cables for shipboard and offshore applications |
I.S. EN 50264-1:2008 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS |
I.S. HD 620:2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV |
IEC 61196-11:2016 | Coaxial communication cables - Part 11: Sectional specification for semi-rigid cables with polyethylene (PE) dielectric |
IEC 62012-1:2002 | Multicore and symmetrical pair/quad cables for digital communications to be used in harsh environments - Part 1: Generic specification |
DD IEC TS 60695-6-2 : DRAFT 2005 | FIRE HAZARD TESTING - PART 6-2: SMOKE OBSCURATION - SUMMARY AND RELEVANCE OF TEST METHODS |
UNE-EN ISO 15791-1:2014 | Plastics - Development and use of intermediate-scale fire tests for plastics products - Part 1: General guidance (ISO 15791-1:2014) |
IEC 60695-6-1:2005+AMD1:2010 CSV | Fire hazard testing - Part 6-1: Smoke obscuration - General guidance |
IEC 60702-1:2002+AMD1:2015 CSV | Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V - Part 1: Cables |
IEC TR 62222:2012 | Fire performance of communication cables installed in buildings |
10/30230568 DC : 0 | BS EN 61892-3 - MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 3: EQUIPMENT |
ISO 15791-1:2014 | Plastics — Development and use of intermediate-scale fire tests for plastics products — Part 1: General guidance |
UNE-IEC 61892-4:2016 | Mobile and fixed offshore units - Electrical installations - Part 4: Cables |
PREN 50525-3-41 : DRAFT 2008 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-41: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE |
BS EN 187103:2003 | Harmonized system of quality assessment for electronic components. Family specification. Optical fibre cables for indoor applications |
04/30114758 DC : 0 | IEC 60092-350 ED.3 - ELECTRICAL INSTALLATION IN SHIP - PART 350: SHIPBOARD POWER CABLES - GENERAL CONSTRUCTION AND TEST REQUIREMENTS |
08/30188836 DC : 0 | BS EN 50525-3-21 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSS LINKED INSULATION, AND LOW EMISSION OF SMOKE |
BIS IS/IEC 60794-1-1 : 2001 | OPTICAL FIBRE CABLES - PART 1: GENERIC SPECIFICATION - SECTION 1: GENERAL |
CEI EN 187103 : 2003 | FAMILY SPECIFICATION - OPTICAL FIBRE CABLES FOR INDOOR APPLICATIONS |
BS EN 50551-2:2013 | Simplex and duplex cables to be used for cords Detailed specification and minimum requirements for a 3,0 mm simplex ruggedised single mode fibre cable to be used for patchcords/cords category U |
UNE-EN 50525-3-41:2012 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 3-41: Cables with special fire performance - Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke |
I.S. EN 50525-3-21:2011 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE |
BS 8492:2009 | Telecommunications equipment and telecommunications cabling. Code of practice for fire performance and protection |
DIN EN 13501-6:2014-07 | FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 6: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS ON ELECTRIC CABLES |
PREN 50525-3-31 : DRAFT 2008 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-31: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE |
BS EN 50411-3-5:2015 | Fibre organisers and closures to be used in optical fibre communication systems. Product specifications Wall outlet |
12/30265027 DC : 0 | BS EN 61196-9 ED.1 - COAXIAL COMMUNICATION CABLES - PART 9: SECTIONAL SPECIFICATION FOR FLEXIBLE RF COAXIAL CABLES |
I.S. EN 50264-2-2:2008 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - MULTICORE CABLES |
NFC 32 201-15 : 2006 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - PART 15: SINGLE CORE CABLES, INSULATED WITH HALOGEN-FREE THERMOPLASTIC COMPOUND, FOR FIXED WIRING |
I.S. HD 605:2008 | ELECTRIC CABLES - ADDITIONAL TEST METHODS |
UNE-EN 50575:2015 | Power, control and communication cables - Cables for general applications in construction works subject to reaction to fire requirements |
05/30139161 DC : DRAFT SEP 2005 | IEC 60794-2-42 - OPTICAL FIBRE CABLES - PART 2-42: INDOOR OPTICAL FIBRE CABLES - PRODUCT SPECIFICATION FOR SIMPLEX AND DUPLEX CABLES WITH A4 FIBRES |
IEC 62821-3:2015 | Electric cables - Halogen-free, low smoke, thermoplastic insulated and sheathed cables of rated voltages up to and including 450/750 V - Part 3: Flexible cables (cords) |
NF EN 50382-1 : 2008 AMD 1 2013 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS |
IEC 61892-4:2007 | Mobile and fixed offshore units - Electrical installations - Part 4: Cables |
UNE-EN 50264-2-2:2010 | Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables |
NF EN 50264-3-2 : 2008 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - MULTICORE CABLES |
I.S. EN 50411-3-8:2016 | FIBRE ORGANIZERS AND CLOSURES TO BE USED IN OPTICAL FIBRE COMMUNICATION SYSTEMS - PRODUCT SPECIFICATIONS - PART 3-8: FIBRE MANAGEMENT SYSTEM, TERMINAL EQUIPMENT BOX TYPE 1 FOR CATEGORY C |
I.S. HD 22.13:2007 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 13: HALOGEN-FREE FLEXIBLE CABLES HAVING LOW EMISSION OF SMOKE |
UNE-IEC 60092-354:2015 | Electrical installations in ships - Part 354: Single- and three-core power cables with extruded solid insulation for rated voltages 6 kV (U<sub>m</sub> = 7,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV) |
UNE-EN 50143:2010 | Cables for signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 000 V but not exceeding 10 000 V |
UNE-IEC 60092-352:2015 | Electrical installations in ships - Part 352: Choice and installation of electrical cables |
NF EN 50264-2-1 : 2008 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES |
PREN 50525-3-21 : DRAFT 2008 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE |
TS 105 175-1 : 2.0.0 | ACCESS, TERMINALS, TRANSMISSION AND MULTIPLEXING (ATTM); PLASTIC OPTICAL FIBRE SYSTEM SPECIFICATIONS FOR 100 MBIT/S AND 1 GBIT/S |
IEC 60502-1:2004+AMD1:2009 CSV | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV(<em>U</em><sub>m</sub> = 36 kV) - Part 1: Cables for rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV) |
I.S. EN 50143:2009 | CABLES FOR SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1000 V BUT NOT EXCEEDING 10000 V |
IEC 60364-4-42:2010+AMD1:2014 CSV | Low-voltage electrical installations - Part 4-42: Protection forsafety - Protection against thermal effects |
ISO/TR 11696-2:1999 | Uses of reaction to fire test results Part 2: Fire hazard assessment of construction products |
DIN EN ISO 15791-1:2014-05 | Plastics - Development and use of intermediate-scale fire tests for plastics products - Part 1: General guidance (ISO 15791-1:2014) |
BS EN 60695-6-2:2011 | Fire hazard testing Smoke obscuration. Summary and relevance of test methods |
HD 22-9 : 200S3 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 9: SINGLE CORE HALOGEN-FREE NON-SHEATHED CABLES FOR FIXED WIRING HAVING LOW EMISSION OF SMOKE |
EN 50143:2009 | Cables for signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 000 V but not exceeding 10 000 V |
CEN/TS 45545-2:2009 | Railway applications - Fire protection on railway vehicles - Part 2: Requirements for fire behaviour of materials and components |
EN 50264-2-2:2008 | Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables |
EN 50551-2:2013 | Simplex and duplex cables to be used for cords - Part 2: Detailed specification and minimum requirements for a 3,0 mm simplex ruggedised single mode fibre cable to be used for patchcords/cords category U |
EN 50264-3-1:2008 | Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables |
EN 62012-1:2002 | Multicore and symmetrical pair/quad cables for digital communications to be used in harsh environments - Part 1: Generic specification |
EN 50382-2:2008/A1:2013 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C |
EN 50525-3-21:2011/AC:2013 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE |
EN 60695-6-2:2011 | FIRE HAZARD TESTING - PART 6-2: SMOKE OBSCURATION - SUMMARY AND RELEVANCE OF TEST METHODS (IEC 60695-6-2:2011) |
EN 50525-3-41:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-41: Cables with special fire performance - Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke |
CEI 18-58 : 2013 | MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 3: EQUIPMENT |
EN 50618:2014 | Electric cables for photovoltaic systems |
UNE-HD 60364-4-42:2014 | Low voltage electrical installations -- Part 4-42: Protection for safety - Protection against thermal effects |
IEC 60695-4:2012 | Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products |
AS/NZS IEC 60092.376:2020 | Electrical installations in ships Cables for control and instrumentation circuits 150/250 V (300 V) |
IEC 60695-6-1:2005+AMD1:2010 CSV | Fire hazard testing - Part 6-1: Smoke obscuration - General guidance |
ISO 13943:2017 | Fire safety — Vocabulary |
IEC GUIDE 104:2010 | The preparation of safety publications and the use of basic safety publications and group safety publications |
AS/NZS 60092.354:2020 | Electrical installations in ships Single- and three-core power cables with extruded solid insulation for rated voltages 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV) (IEC 60092-354:2014 (ED.3.0) MOD) |
AS/NZS IEC 60092.353:2020 | Electrical installations in ships Power cables for rated voltages 1 kV and 3 kV |
IEC 61034-1:2005+AMD1:2013 CSV | Measurement of smoke density of cables burning under defined conditions - Part 1: Test apparatus |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.