IEC 61000-2-11:1999

Current

Current

The latest, up-to-date edition.

Electromagnetic compatibility (EMC) - Part 2-11: Environment - Classification of HEMP environments

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English - French, Spanish, Castilian

Published date

29-10-1999

£71.17
Excluding VAT

Foreword
      Introduction
1 Scope
2 Normative References
3 General
4 Definitions
5 Description of Protective Concepts
6 Classification of Environments, Early-Time HEMP
7 Classification of Environments, Intermediate-Time HEMP
8 Classification of Environments, Late-Time HEMP
9 Principles of the selection of Immunity Levels
      9.1 Approach
      9.2 Test Uncertainties
      9.3 Criticality Criteria
      9.4 Conclusion
Table 1 - Minimum required attenuation of peak time domain
          external environments for the six principal
          protection concepts
Table 2 - Classification of radiated early-time HEMP
          environments
Table 3 - Classification of conducted common-mode early-time
          HEMP environments
Table 4 - Classification of radiated intermediate-time HEMP
          environments
Table 5 - Classification of conducted common-mode
          intermediate-time HEMP environments for power or
          communications lines
Table 6 - Classification example of electric field and
          conducted common-mode late-time HEMP environment
          for a grounded power transmission line
Table 7 - Classification example of electric field and
          conducted common-mode late-time HEMP environment
          for a telecommunication line
Bibliography

The purpose of this publication is to help specify the immunity requirements of an item (e.g. equipment or subsystem) containing electrical or electronic parts to ensure that it will operate during and/or after exposure to a high-altitude electromagnetic pulse (HEMP) waveform. It provides basic guidance for the selection of immunity test levels for any component, device, equipment, subsystem or system which contains electrical circuits that may be disturbed by electromagnetic signals.

Committee
TC 77/SC 77C
DevelopmentNote
Stability date: 2020. (11/2017)
DocumentType
Standard
Pages
31
PublisherName
International Electrotechnical Committee
Status
Current

I.S. EN 61000-4-25:2002 ELECTROMAGNETIC COMPATIBILITY (EMC) - TESTING AND MEASUREMENT TECHNIQUES - HEMP IMMUNITY TEST METHODS FOR EQUIPMENT AND SYSTEMS (IEC 61000-4-25:2001 (EQV))
01/204707 DC : DRAFT JUL 2001 IEC 61000-6-6 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-6: GENERIC STANDARDS - HEMP IMMUNITY FOR INDOOR EQUIPMENT
95/210789 DC : DRAFT AUG 1995 IEC 61000-5-6 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 5: MITIGATION METHODS AND INSTALLATION GUIDELINES - SECTION 6: MITIGATION OF EXTERNAL INFLUENCES - TECHNICAL REPORT TYPE 2
02/204753 DC : DRAFT APR 2002 IEC 61000-2-13. ED. 1 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-13: ENVIRONMENT - HIGH-POWER ELECTROMAGNETIC ENVIRONMENTS (HPEM) - RADIATED AND CONDUCTED
BS IEC 61000-6-6:2003 Electromagnetic compatibility (EMC) Generic standards - HEMP immunity for indoor equipment
EN 61000-4-20:2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-20: TESTING AND MEASUREMENT TECHNIQUES - EMISSION AND IMMUNITY TESTING IN TRANSVERSE ELECTROMAGNETIC (TEM) WAVEGUIDES
PD IEC/TS 61000-5-10:2017 Electromagnetic compatibility (EMC) Installation and mitigation guidelines. Guidance on the protection of facilities against HEMP and IEMI
BS EN 61000-4-20:2003 Electromagnetic Compatibility (EMC) Testing and measurement techniques. Emission and immunity testing in transverse electromagnetic (TEM) waveguides
IEC 61000-4-33:2005 Electromagnetic compatibility (EMC) - Part 4-33: Testing and measurement techniques - Measurement methods for high-power transient parameters
IEC TR 61000-5-6:2002 Electromagnetic compatibility (EMC) - Part 5-6: Installation and mitigation guidelines - Mitigation of external EM influences
IEC 61000-6-6:2003 Electromagnetic compatibility (EMC) - Part 6-6: Generic standards - HEMP immunity for indoor equipment
IEC TR 61000-2-5:2017 Electromagnetic compatibility (EMC) - Part 2-5: Environment - Description and classification of electromagnetic environments
NF EN 61000-4-20 : 2011 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-20: TESTING AND MEASUREMENT TECHNIQUES - EMISSION AND IMMUNITY TESTING IN TRANSVERSE ELECTROMAGNETIC (TEM) WAVEGUIDES
IEC 61000-2-13:2005 Electromagnetic compatibility (EMC) - Part 2-13: Environment - High-power electromagnetic (HPEM) environments - Radiated and conducted
IEC TS 61000-5-9:2009 Electromagnetic compatibility (EMC) - Part 5-9: Installation and mitigation guidelines - System-level susceptibility assessments for HEMP and HPEM
IEC 61000-4-24:2015 Electromagnetic compatibility (EMC) - Part 4-24: Testing and measurement techniques - Test methods for protective devices for HEMP conducted disturbance
CEI EN 61000-4-20 : 2013 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-20: TESTING AND MEASUREMENT TECHNIQUES - EMISSION AND IMMUNITY TESTING IN TRANSVERSE ELECTROMAGNETIC (TEM) WAVEGUIDES
IEC TS 61000-5-8:2009 Electromagnetic compatibility (EMC) - Part 5-8: Installation and mitigation guidelines - HEMP protection methods for the distributed infrastructure
08/30181498 DC : DRAFT APR 2008 BS EN 61000-5-8 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 5-8: INSTALLATION AND MITIGATION GUIDELINES - HEMP PROTECTION METHODS FOR THE DISTRIBUTED INFRASTRUCTURE
BS EN 61000-4-25 : 2002 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-25: TESTING AND MEASUREMENT TECHNIQUES - HEMP IMMUNITY TEST METHODS FOR EQUIPMENT AND SYSTEMS
DD IEC/TS 61000-5-9:2009 Electromagnetic compatibility (EMC) Installation and mitigation guidelines. System-level susceptibility assessments for HEMP and HPEM
PD IEC TR 61000-5-6:2002 Electromagnetic compatibility (EMC). Installation and mitigation guidelines Mitigation of external EM influences
DD IEC/TS 61000-5-8:2009 Electromagnetic compatibility (EMC) Installation and mitigation guidelines. HEMP protection methods for the distributed infrastructure
PD IEC/TR 61000-2-5:2017 Electromagnetic compatibility (EMC) Environment. Description and classification of electromagnetic environments
IEC TR 61000-5-3:1999 Electromagnetic compatibility (EMC) - Part 5-3: Installation and mitigation guidelines - HEMP protection concepts
07/30168004 DC : 0 BS EN 61000-4-35 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-35: TESTING AND MEASUREMENT TECHNIQUES - HIGH POWER ELECTROMAGNETIC (HPEM) SIMULATOR COMPENDIUM
13/30285924 DC : 0 BS EN 61000-4-24 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-24: TESTING AND MEASUREMENT TECHNIQUES - TEST METHODS FOR PROTECTIVE DEVICES FOR HEMP CONDUCTED DISTURBANCE
BS EN 60044-7:2000 Instrument transformers Electronic voltage transformers
07/30167970 DC : 0 BS EN 61000-5-9 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 5-9: INSTALLATION AND MITIGATION GUIDELINES - SYSTEM-LEVEL SUSCEPTIBILITY ASSESSMENTS FOR HEMP AND HPEM
IEC 61000-4-25:2001+AMD1:2012 CSV Electromagnetic compatibility (EMC) - Part 4-25: Testing and measurement techniques - HEMP immunity test methods for equipment and systems
I.S. EN 61000-4-20:2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-20: TESTING AND MEASUREMENT TECHNIQUES - EMISSION AND IMMUNITY TESTING IN TRANSVERSE ELECTROMAGNETIC (TEM) WAVEGUIDES
UNE-EN 61000-4-20:2011 Electromagnetic compatibility (EMC) -- Part 4-20: Testing and measurement techniques - Emission and immunity testing in Transverse Electromagnetic (TEM) waveguides - Basic EMC publication
IEC TS 61000-5-10:2017 Electromagnetic compatibility (EMC) - Part 5-10: Installation and mitigation guidelines - Guidance on the protection of facilities against HEMP and IEMI
EN 61000-4-25 : 2002 AMD 1 2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-25: TESTING AND MEASUREMENT TECHNIQUES - HEMP IMMUNITY TEST METHODS FOR EQUIPMENT AND SYSTEMS (IEC 61000-4-25:2001/A1:2012)
IEC 61000-4-20:2010 Electromagnetic compatibility (EMC) - Part 4-20: Testing and measurement techniques - Emission and immunity testing in transverse electromagnetic (TEM) waveguides
IEC TR 61000-2-5:2017 RLV Electromagnetic compatibility (EMC) - Part 2-5: Environment - Description and classification of electromagnetic environments

IEC TR 61000-5-3:1999 Electromagnetic compatibility (EMC) - Part 5-3: Installation and mitigation guidelines - HEMP protection concepts
IEC 61000-2-10:1998 Electromagnetic compatibility (EMC) - Part 2-10: Environment - Description of HEMP environment - Conducted disturbance
SA TR IEC 61000.2.5:2019 Electromagnetic compatibility (EMC) Environment - Description and classification of electromagnetic environments
IEC 61000-2-9:1996 Electromagnetic compatibility (EMC) - Part 2: Environment - Section 9: Description of HEMP environment - Radiated disturbance. Basic EMC publication