IEC 60947-5-4:2002
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Low-voltage switchgear and controlgear - Part 5-4: Control circuit devices and switching elements - Method of assessing the performance of low-energy contacts - Special tests
Hardcopy , PDF
Spanish, Castilian
15-10-2002
22-05-2019
FOREWORD
INTRODUCTION
1 Scope and object
2 Normative references
3 Definitions and list of symbols used
3.1 Definitions
3.2 List of symbols used
4 General principles
5 General test method
6 General characteristics
6.1 Measurement methods
6.2 Sequences of operations
6.3 Electrical characteristics
6.4 Characteristics of operation
7 Characterization of defects
7.1 Basic method
7.2 Monitoring the load (figure 3)
8 Ambient conditions
8.1 Normal conditions
8.2 Preconditioning
8.3 Particular conditions
9 Methods of reporting
9.1 Failure criterion
9.2 Reporting the failure rate
10 Information to be provided in the test report
Annex A (normative) Information to be supplied by the
manufacturer
Bibliography
Figures
Tables
IEC 60947-5-4:2002 applies to separable contacts used in the utilization area considered, such as switching elements for control circuits. This standard takes into consideration two rated voltage areas:
a) above (and including) 10 V (typically 24 V) where contacts are used for switching loads with possible electrical erosion, such as programmable controller inputs;
b) below 10 V (typically 5 V) with negligible electrical erosion, such as electronic circuits.
This second edition cancels and replaces the first edition which was issued as a technical report in 1996. It now has the status of an International Standard.
| Committee |
TC 121/SC 121A
|
| DevelopmentNote |
Stability Date: 2019. (09/2017)
|
| DocumentType |
Standard
|
| Pages |
57
|
| PublisherName |
International Electrotechnical Committee
|
| Status |
Superseded
|
| SupersededBy |
| Standards | Relationship |
| AS 60947.5.4-2004 | Identical |
| GOST IEC 60947-5-4 : 2014 | Identical |
| NF EN 60947-5-4 : 2004 | Identical |
| NEN EN IEC 60947-5-4 : 2004 | Identical |
| I.S. EN 60947-5-4:2003 | Identical |
| PN EN 60947-5-4 : 2005 | Identical |
| AS/NZS IEC 60947.5.4:2015 | Identical |
| VDE 0660-211 : 2005 | Identical |
| CEI EN 60947-5-4 : 2005 | Identical |
| EN 60947-5-4:2003 | Identical |
| BS EN 60947-5-4:2003 | Identical |
| UNE-EN 60947-5-4:2005 | Identical |
| DIN EN 60947-5-4 : 2005 | Identical |
| 08/30195483 DC : 0 | BS EN 61812-1 - TIME RELAYS FOR INDUSTRIAL AND RESIDENTIAL USE - PART 1: REQUIREMENTS AND TESTS |
| BS EN 61557-8:2015 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures Insulation monitoring devices for IT systems |
| 04/30125208 DC : DRAFT NOV 2004 | IEC 61557-8 ED.2 - ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. V D.C. EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 8: INSULATION MONITORING DEVICES FOR IT SYSTEMS |
| EN 62019:1999/A12:2014 | ELECTRICAL ACCESSORIES - CIRCUIT-BREAKERS AND SIMILAR EQUIPMENT FOR HOUSEHOLD USE - AUXILIARY CONTACT UNITS |
| EN 62683:2015 | Low-voltage switchgear and controlgear - Product data and properties for information exchange |
| I.S. EN 62683:2015 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PRODUCT DATA AND PROPERTIES FOR INFORMATION EXCHANGE |
| EN 61557-8:2015/AC:2016-06 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems |
| CEI EN 61812-1 : 2012 | TIME RELAYS FOR INDUSTRIAL AND RESIDENTIAL USE - PART 1: REQUIREMENTS AND TESTS |
| BS EN 61812-1:2011 | Time relays for industrial and residential use Requirements and tests |
| API 551 : 2016 | PROCESS MEASUREMENT |
| I.S. EN 62019:2000 | ELECTRICAL ACCESSORIES - CIRCUIT-BREAKERS AND SIMILAR EQUIPMENT FOR HOUSEHOLD USE - AUXILIARY CONTACT UNITS |
| I.S. EN 61557-9:2015 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 9: EQUIPMENT FOR INSULATION FAULT LOCATION IN IT SYSTEMS |
| I.S. EN 61812-1:2011 | TIME RELAYS FOR INDUSTRIAL AND RESIDENTIAL USE - PART 1: REQUIREMENTS AND TESTS |
| BS EN 62683:2015 | Low-voltage switchgear and controlgear. Product data and properties for information exchange |
| I.S. EN 61557-8:2015 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 8: INSULATION MONITORING DEVICES FOR IT SYSTEMS |
| IEC 61557-8:2014 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems |
| IEC 61557-9:2014 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 9: Equipment for insulation fault location in IT systems |
| 13/30292412 DC : 0 | BS EN 62683 - PRODUCT DATA AND PROPERTIES FOR INFORMATION EXCHANGE |
| IEC 61812-1:2011 | Time relays for industrial and residential use - Part 1: Requirements and tests |
| IEC 62019:1999+AMD1:2002 CSV | Electrical accessories - Circuit-breakers and similar equipment for household use - Auxiliary contact units |
| CEI EN 61557-8 : 2016 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 8: INSULATION MONITORING DEVICES FOR IT SYSTEMS |
| NF EN 62019 : 99 AMD 12 2015 | ELECTRICAL ACCESSORIES - CIRCUIT-BREAKERS AND SIMILAR EQUIPMENT FOR HOUSEHOLD USE - AUXILIARY CONTACT UNITS |
| 12/30274737 DC : 0 | BS EN 61557-9 - ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 9: EQUIPMENT FOR INSULATION FAULT LOCATION IN IT SYSTEMS |
| 12/30274733 DC : 0 | BS EN 61557-8 - ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 8: INSULATION MONITORING DEVICES FOR IT SYSTEMS |
| BS EN 61557-9:2015 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures Equipment for insulation fault location in IT systems |
| EN 61557-9:2015/AC:2017-02 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 9: EQUIPMENT FOR INSULATION FAULT LOCATION IN IT SYSTEMS (IEC 61557-9:2014/COR2:2017) |
| EN 61812-1:2011 | Time relays for industrial and residential use - Part 1: Requirements and tests |
| UNE-EN 61557-8:2016 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems |
| UNE-EN 61812-1:2012 | Time relays for industrial and residential use - Part 1: Requirements and tests |
| UNE-EN 62683:2016 | Low-voltage switchgear and controlgear - Product data and properties for information exchange |
| IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
| IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
| IEC 60605-6:2007 | Equipment reliability testing - Part 6: Tests for the validity and estimation of the constant failure rate and constant failure intensity |
| ISO 8402:1994 | Quality management and quality assurance — Vocabulary |
| IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV | Low-voltage switchgear and controlgear - Part 1: General rules |
| IEC 61131-2:2017 | Industrial-process measurement and control - Programmable controllers - Part 2: Equipment requirements and tests |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.