IEC 60913:2013
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Railway applications - Fixed installations - Electric traction overhead contact lines
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
08-04-2024
English - French
06-03-2013
FOREWORD
1 Scope
2 Normative references
3 Terms, definitions, symbols and abbreviations
4 Fundamental design data
5 System requirements
6 Structures
7 Component requirements
8 Testing
9 Minimum documentation
Annex A (informative) - Current-carrying capacity
of conductors
Annex B (informative) - Structural details
Annex C (informative) - Geotechnical soil investigation
and soil characteristics
Annex D (informative) - Information on uniformity of
elasticity of OCL within a span length
Annex E (normative) - Special national conditions
Bibliography
IEC 60913:2013 applies to electric traction overhead contact line systems in heavy railways, light railways, trolley busses and industrial railways of public and private operators. It applies to new installations of overhead contact line systems and for the complete reconstruction of existing overhead contact line systems. It provides the requirements and tests for the design of overhead contact lines, requirements for structures and their structural calculations and verifications as well as the requirements and tests for the design of assemblies and individual parts. The main technical changes with regard to the previous edition deal with:
- fundamental design data,
- system requirements,
- structures,
- components requirements, and
- testing.
DevelopmentNote |
Stability date: 2021. (11/2017)
|
DocumentType |
Standard
|
Pages |
202
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
SAC GB/T 32578 : 2016 | Identical |
I.S. EN 62621:2016 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION - SPECIFIC REQUIREMENTS FOR COMPOSITE INSULATORS USED FOR OVERHEAD CONTACT LINE SYSTEMS |
11/30230287 DC : 0 | BS IEC 60494-1 - RAILWAY APPLICATIONS - ROLLING STOCK - PANTOGRAPHS - CHARACTERISTICS AND TESTS - PART 1: PANTOGRAPHS FOR MAIN LINES VEHICLES |
IEC 62498-2:2010 | Railway applications - Environmental conditions for equipment - Part 2: Fixed electrical installations |
IEC 60494-1:2013 | Railway applications - Rolling stock - Pantographs - Characteristics and tests - Part 1: Pantographs for main line vehicles |
IEC 62505-2:2016 | Railway applications - Fixed installations - Particular requirements for AC switchgear - Part 2: Disconnectors, earthing switches and switches with nominal voltage above 1 kV |
IEC 62128-1:2013 | Railway applications - Fixed installations - Electrical safety, earthing and the return circuit - Part 1: Protective provisions against electric shock |
BS EN 62621 : 2016 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION - SPECIFIC REQUIREMENTS FOR COMPOSITE INSULATORS USED FOR OVERHEAD CONTACT LINE SYSTEMS (IEC 62621:2011) |
IEC 61992-1:2006+AMD1:2014 CSV | Railway applications - Fixed installations - DC switchgear - Part 1:General |
IEC 61992-4:2006+AMD1:2015 CSV | Railway applications - Fixed installations - DC switchgear - Part 4:Outdoor d.c. disconnectors, switch-disconnectors and earthing switches |
IEC 62724:2013 | Railway applications - Fixed installations - Electric traction - Insulating synthetic rope assemblies for support of overhead contact lines |
IEC 62621:2011 | Railway applications - Fixed installations - Electric traction - Specific requirements for composite insulators used for overhead contact line systems |
UNE-EN 62621:2016 | Railway applications - Fixed installations - Electric traction - Specific requirements for composite insulators used for overhead contact line systems |
08/30160532 DC : DRAFT MAY 2008 | BS EN 50122-1 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRICAL SAFETY, EARTHING AND BONDING - PART 1: PROTECTIVE PROVISIONS AGAINST ELECTRIC SHOCK |
IEC 62846:2016 | Railway applications - Current collection systems - Requirements for and validation of measurements of the dynamic interaction between pantograph and overhead contact line |
IEC 60850:2014 | Railway applications - Supply voltages of traction systems |
IEC 62486:2017 | Railway applications - Current collection systems - Technical criteria for the interaction between pantograph and overhead contactline (to achieve free access) |
IEC 62505-1:2016 | Railway applications - Fixed installations - Particular requirements for AC switchgear - Part 1: Circuit-breakers with nominal voltage above 1 kV |
12/30251569 DC | BS IEC 62128-1. Railway applications. Fixed installations. Electrical safety, earthing and the return circuit. Part 1. Protective provisions against electric shock |
EN 62621:2016/A1:2016 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION - SPECIFIC REQUIREMENTS FOR COMPOSITE INSULATORS USED FOR OVERHEAD CONTACT LINE SYSTEMS |
UIC 606-1 : 1987 AMD 1 | CONSEQUENCES OF THE APPLICATION OF THE KINEMATIC GAUGES DEFINED BY UIC LEAFLETS IN THE 505 SERIES ON THE DESIGN OF THE CONTACT LINES |
EN 50189:2000 | Conductors for overhead lines - Zinc coated steel wires |
EN 12465 : 2001 | WOOD POLES FOR OVERHEAD LINES - DURABILITY REQUIREMENTS |
ISO 898-2:2012 | Mechanical properties of fasteners made of carbon steel and alloy steel — Part 2: Nuts with specified property classes — Coarse thread and fine pitch thread |
IEC 61325:1995 | Insulators for overhead lines with a nominal voltage above 1000 V - Ceramic or glass insulator units for d.c. systems - Definitions, test methods and acceptance criteria |
ISO 22476-2:2005 | Geotechnical investigation and testing Field testing Part 2: Dynamic probing |
EN 485-1:2016 | Aluminium and aluminium alloys - Sheet, strip and plate - Part 1: Technical conditions for inspection and delivery |
EN 755-1:2016 | Aluminium and aluminium alloys - Extruded rod/bar, tube and profiles - Part 1: Technical conditions for inspection and delivery |
EN 12843:2004 | Precast concrete products - Masts and poles |
IEC 60826:2017 | Design criteria of overhead transmission lines |
EN 50326:2002 | Conductors for overhead lines - Characteristics of greases |
UIC 606-2 : 4ED 1986 | INSTALLATION OF 25 KV AND 50 OR 60 HZ OVERHEAD CONTACT LINES |
ISO 3010:2017 | Bases for design of structures — Seismic actions on structures |
IEC 62128-1:2013 | Railway applications - Fixed installations - Electrical safety, earthing and the return circuit - Part 1: Protective provisions against electric shock |
IEC 60050-811:1991 | International Electrotechnical Vocabulary (IEV) - Part 811: Electric traction |
IEC 60305:1995 | Insulators for overhead lines with a nominal voltage above 1000 V - Ceramic or glass insulator units for a.c. systems - Characteristics of insulator units of the cap and pin type |
EN 50318:2002 | Railway applications - Current collection systems - Validation of simulation of the dynamic interaction between pantograph and overhead contact line |
CLC/TS 50502:2008 | Railway applications - Rolling stock - Electric equipment in trolley buses - Safety requirements and connection systems |
EN 1536:2010+A1:2015 | Execution of special geotechnical work - Bored piles |
EN 10164:2004 | Steel products with improved deformation properties perpendicular to the surface of the product - Technical delivery conditions |
IEC 60099-4:2014 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
ISO 14688-1:2002 | Geotechnical investigation and testing Identification and classification of soil Part 1: Identification and description |
ISO/TR 11069:1995 | Aluminium structures — Material and design — Ultimate limit state under static loading |
IEC 61992-5:2006 | Railway applications - Fixed installations - DC switchgear - Part 5: Surge arresters and low-voltage limiters for specific use in d.c. systems |
ISO 4354:2009 | Wind actions on structures |
IEC 60494-1:2013 | Railway applications - Rolling stock - Pantographs - Characteristics and tests - Part 1: Pantographs for main line vehicles |
ISO 12633-2:2011 | Hot-finished structural hollow sections of non-alloy and fine grain steels — Part 2: Dimensions and sectional properties |
ISO 2394:2015 | General principles on reliability for structures |
ISO 3898:2013 | Bases for design of structures — Names and symbols of physical quantities and generic quantities |
SAC GB/T 1179 : 1999 | ROUND WIRE CONCENTRIC LAY OVERHEAD ELECTRICAL STRANDED CONDUCTORS |
UIC 608 : 3ED 2003 | CONDITIONS TO BE COMPLIED WITH FOR THE PANTOGRAPHS OF TRACTIVE UNITS USED IN INTERNATIONAL SERVICES |
UIC 505-5 : 3ED 2010 | HISTORY, JUSTIFICATION AND COMMENTARIES ON THE ELABORATION AND DEVELOPMENT OF UIC LEAFLETS OF THE SERIES 505 AND 506 ON GAUGES |
UIC 505-1 : 10ED 2006 | RAILWAY TRANSPORT STOCK - ROLLING STOCK CONSTRUCTION GAUGE |
IEC 61109:2008 | Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria |
IEC 60672-3:1997 | Ceramic and glass-insulating materials - Part 3: Specifications for individual materials |
IEC 60660:1999 | Insulators - Tests on indoor post insulators of organic material for systems with nominal voltages greater than 1 000 V up to but not including 300 kV |
ISO 1461:2009 | Hot dip galvanized coatings on fabricated iron and steel articles — Specifications and test methods |
EN 50183:2000 | Conductors for overhead lines - Aluminium-magnesium-silicon alloy wires |
EN 20898-2 : 1993 | MECHANICAL PROPERTIES OF FASTENERS - PART 2: NUTS WITH SPECIFIED PROOF LOAD VALUES - COARSE THREAD (ISO 898-2:1992) |
EN 10025-1:2004 | Hot rolled products of structural steels - Part 1: General technical delivery conditions |
IEC 60850:2014 | Railway applications - Supply voltages of traction systems |
EN 1090-1:2009+A1:2011 | Execution of steel structures and aluminium structures - Part 1: Requirements for conformity assessment of structural components |
EN 50317:2012/AC:2012 | RAILWAY APPLICATIONS - CURRENT COLLECTION SYSTEMS - REQUIREMENTS FOR AND VALIDATION OF MEASUREMENTS OF THE DYNAMIC INTERACTION BETWEEN PANTOGRAPH AND OVERHEAD CONTACT LINE |
IEC 62305-1:2010 | Protection against lightning - Part 1: General principles |
IEC 61952:2008 | Insulators for overhead lines - Composite line post insulators for A.C. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria |
ISO 22475-1:2006 | Geotechnical investigation and testing Sampling methods and groundwater measurements Part 1: Technical principles for execution |
IEC 61992-4:2006+AMD1:2015 CSV | Railway applications - Fixed installations - DC switchgear - Part 4:Outdoor d.c. disconnectors, switch-disconnectors and earthing switches |
ISO 14689-1:2003 | Geotechnical investigation and testing Identification and classification of rock Part 1: Identification and description |
EN 12510:2001/AC:2002 | WOOD POLES FOR OVERHEAD LINES - STRENGTH GRADING CRITERIA |
IEC 62236-2:2008 | Railway applications - Electromagnetic compatibility - Part 2: Emission of the whole railway system to the outside world |
ISO 13823:2008 | General principles on the design of structures for durability |
EN 12479 : 2001 | WOOD POLES FOR OVERHEAD LINES - SIZES - METHODS OF MEASUREMENT AND PERMISSIBLE DEVIATIONS |
IEC 60494-2:2013 | Railway applications - Rolling stock - Pantographs - Characteristics and tests - Part 2: Pantographs for metros and light rail vehicles |
IEC 60889:1987 | Hard-drawn aluminium wire for overhead line conductors |
ISO 22476-3:2005 | Geotechnical investigation and testing — Field testing — Part 3: Standard penetration test |
ISO 14688-2:2004 | Geotechnical investigation and testing Identification and classification of soil Part 2: Principles for a classification |
EN 50119 : 2009 AMD 1 2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
IEC 62271-103:2011 | High-voltage switchgear and controlgear - Part 103: Switches for rated voltages above 1 kV up to and including 52 kV |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC TS 61245:2015 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on d.c. systems |
IEC 60273:1990 | Characteristic of indoor and outdoor post insulators for systems with nominal voltages greater than 1000 V |
IEC 62278:2002 | Railway applications - Specification and demonstration of reliability, availability, maintainability and safety (RAMS) |
IEC 60099-1:1991+AMD1:1999 CSV | Surge arresters - Part 1: Non-linear resistor type gapped surge arresters for a.c. systems |
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV | Low-voltage switchgear and controlgear - Part 1: General rules |
EN 50345:2009 | Railway applications - Fixed installations - Electric traction - Insulating synthetic rope assemblies for support of overhead contact lines |
IEC 62128-2:2013 | Railway applications - Fixed installations - Electrical safety, earthing and the return circuit - Part 2: Provisions against the effects of stray currents caused by d.c. traction systems |
EN 50341-1:2012 | Overhead electrical lines exceeding AC 1 kV - Part 1: General requirements - Common specifications |
ISO 4356:1977 | Bases for the design of structures Deformations of buildings at the serviceability limit states |
IEC 62505-2:2016 | Railway applications - Fixed installations - Particular requirements for AC switchgear - Part 2: Disconnectors, earthing switches and switches with nominal voltage above 1 kV |
ENV 1991-2-4 : 1995 | EUROCODE 1: BASIS OF DESIGN AND ACTIONS ON STRUCTURES - ACTIONS ON STRUCTURES - WIND ACTIONS (TOGETHER WITH UNITED KINGDOM NATIONAL APPLICATION DOCUMENT) |
IEC 62497-2:2010 | Railway applications - Insulation coordination - Part 2: Overvoltages and related protection |
ISO 4355:2013 | Bases for design of structures — Determination of snow loads on roofs |
IEC 60652:2002 | Loading tests on overhead line structures |
UIC 791 : 2ED 1990 | QUALITY ASSURANCE OF OVERHEAD LINE EQUIPMENT |
ISO 10137:2007 | Bases for design of structures - Serviceability of buildings and walkways against vibrations |
IEC 60672-2:1999 | Ceramic and glass insulating materials - Part 2: Methods of test |
EN 50182:2001/AC:2013 | CONDUCTORS FOR OVERHEAD LINES - ROUND WIRE CONCENTRIC LAY STRANDED CONDUCTORS |
EN 12509 : 2001 | TIMBER POLES FOR OVERHEAD LINES - TEST METHODS - DETERMINATION OF MODULUS OF ELASTICITY, BENDING STRENGTH, DENSITY AND MOISTURE CONTENT |
UIC 794 : 1ED 1996 | PANTOGRAPH-OVERHEAD LINE INTERACTION ON THE EUROPEAN HIGH-SPEED NETWORK |
IEC 61992-1:2006+AMD1:2014 CSV | Railway applications - Fixed installations - DC switchgear - Part 1:General |
IEC 62305-4:2010 | Protection against lightning - Part 4: Electrical and electronic systems within structures |
IEC 62497-1:2010+AMD1:2013 CSV | Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electricaland electronic equipment |
IEC 62305-2:2010 | Protection against lightning - Part 2: Risk management |
IEC 61232:1993 | Aluminium-clad steel wires for electrical purposes |
IEC 60433:1998 | Insulators for overhead lines with a nominal voltage above 1 000 V - Ceramic insulators for a.c. systems - Characteristics of insulator units of the long rod type |
EN 50149:2012 | Railway applications - Fixed installations - Electric traction - Copper and copper alloy grooved contact wires |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 62486:2017 | Railway applications - Current collection systems - Technical criteria for the interaction between pantograph and overhead contactline (to achieve free access) |
UIC 505-4 : 4ED 2007 | EFFECTS OF THE APPLICATION OF THE KINEMATIC GAUGES DEFINED IN THE 505 SERIES OF LEAFLETS ON THE POSITIONING OF STRUCTURES IN RELATION TO THE TRACKS AND OF THE TRACKS IN RELATION TO EACH OTHER |
EN 1537:2013 | Execution of special geotechnical works - Ground anchors |
IEC 62498-2:2010 | Railway applications - Environmental conditions for equipment - Part 2: Fixed electrical installations |
UIC 600 : 4ED 2003 | ELECTRIC TRACTION WITH AERIAL CONTACT LINE |
ISO 22966:2009 | Execution of concrete structures |
EN 12511 : 2001 | WOOD POLES FOR OVERHEAD LINES - DETERMINATION OF CHARACTERISTIC VALUES |
ISO 16160:2012 | Hot-rolled steel sheet products — Dimensional and shape tolerances |
ISO 630-2:2011 | Structural steels Part 2: Technical delivery conditions for structural steels for general purposes |
IEC 62305-3:2010 | Protection against lightning - Part 3: Physical damage to structures and life hazard |
IEC 62621:2011 | Railway applications - Fixed installations - Electric traction - Specific requirements for composite insulators used for overhead contact line systems |
ISO 23469:2005 | Bases for design of structures Seismic actions for designing geotechnical works |
EN 12699:2015 | Execution of special geotechnical works - Displacement piles |
EN 755-2:2016 | Aluminium and aluminium alloys - Extruded rod/bar, tube and profiles - Part 2: Mechanical properties |
IEC 62271-102:2001+AMD1:2011+AMD2:2013 CSV | High-voltage switchgear and controlgear - Part 102: Alternatingcurrent disconnectors and earthing switches |
IEC 60168:1994+AMD1:1997+AMD2:2000 CSV | Tests on indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V |
ISO 898-1:2013 | Mechanical properties of fasteners made of carbon steel and alloy steel — Part 1: Bolts, screws and studs with specified property classes — Coarse thread and fine pitch thread |
IEC 60672-1:1995 | Ceramic and glass insulating materials - Part 1: Definitions and classification |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.