IEC 60669-2-5:2013
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Switches for household and similar fixed electrical installations - Part 2-5: Particular requirements - Switches and related accessories for use in home and building electronic systems (HBES)
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
28-02-2023
English - French, Spanish, Castilian
14-10-2013
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 General notes on tests
6 Rating
7 Classification
8 Marking
9 Checking of dimensions
10 Protection against electric shock
11 Provision for earthing
12 Terminals
13 Constructional requirements
14 Mechanism
15 Resistance to ageing, protection provided
by enclosures of switches, and resistance
to humidity
16 Insulation resistance and electric strength
17 Temperature rise
18 Making and breaking capacity
19 Normal operation
20 Mechanical strength
21 Resistance to heat
22 Screws, current-carrying parts and connections
23 Creepage distances, clearances and distances
through sealing compound
24 Resistance of insulating material to abnormal
heat, to fire and to tracking
25 Resistance to rusting
26 EMC requirements
101 Abnormal conditions
102 Components
Annex A (normative) - Survey of specimens needed
for tests
Annex B (normative) - Additional requirements for
switches having facilities for the outlet and
retention of flexible cables
Annex C (informative) - Examples of types of electronic
switches and their functions
Annex AA (normative) - Measurement of clearances
and creepage distances
Annex BB (informative) - Test set-ups
Bibliography
IEC 60669-2-5:2013 applies to HBES switches with a working voltage not exceeding 250 V a.c. and a rated current up to and including 16 A for household and similar fixed electrical installations either indoors or outdoors and to associated electronic extension units.
Committee |
TC 23/SC 23B
|
DevelopmentNote |
Stability date: 2017. (10/2017)
|
DocumentType |
Standard
|
Pages |
91
|
PublisherName |
International Electrotechnical Committee
|
Status |
Withdrawn
|
Standards | Relationship |
SN EN 60669-2-5:2016 | Identical |
VDE 0632-2-5 : 2017 | Identical |
DIN EN 60669-2-5 : 2017 | Identical |
SAC GB/T 16915.6 : 2015 | Identical |
EN 60669-2-5:2016 | Identical |
NF EN 60669-2-5 : 2016 | Identical |
UNE-EN 60669-2-5:2017 | Identical |
BS EN 60695-8-1:2017 | Identical |
IEC 63044-5-1:2017 | Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) - Part 5-1: EMC requirements, conditions and test set-up |
I.S. EN IEC 63044-3:2018 | HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) AND BUILDING AUTOMATION AND CONTROL SYSTEMS (BACS) - PART 3: ELECTRICAL SAFETY REQUIREMENTS |
S.R. HD 60364-5-537:2016 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - DEVICES FOR PROTECTION, ISOLATION, SWITCHING, CONTROL AND MONITORING - CLAUSE 537: ISOLATION AND SWITCHING |
BS EN IEC 63044-3:2018 | Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) Electrical safety requirements |
IEC 60669-1:2017 RLV | Switches for household and similar fixed-electrical installations - Part 1: General requirements |
EN IEC 63044-3:2018 | Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) - Part 3: Electrical safety requirements |
IEC 60669-1:2017 | Switches for household and similar fixed-electrical installations - Part 1: General requirements |
16/30319349 DC : 0 | BS EN 62962 ED1.0 - PARTICULAR REQUIREMENTS FOR LOAD-SHEDDING EQUIPMENT (LSE) |
EN 60669-1:2018 | Switches for household and similar fixed electrical installations - Part 1: General requirements |
HD 60364-5-537:2016/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - DEVICES FOR PROTECTION, ISOLATION, SWITCHING, CONTROL AND MONITORING - CLAUSE 537: ISOLATION AND SWITCHING |
UNE-HD 60364-5-537:2017 | Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Devices for protection, isolation, switching, control and monitoring - Clause 537: Isolation and switching |
IS 3854 : 2023 | Switches for Domestic and Similar Purposes - Specification |
IEC 60950-1:2005+AMD1:2009+AMD2:2013 CSV | Information technology equipment - Safety - Part 1: General requirements |
IEC 60998-1:2002 | Connecting devices for low-voltage circuits for household and similar purposes - Part 1: General requirements |
IEC 60670-1:2015 | Boxes and enclosures for electrical accessories for household and similar fixed electrical installations - Part 1: General requirements |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
IEC 61000-4-8:2009 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
CISPR 15:2013+AMD1:2015 CSV | Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 60669-2-1:2002+AMD1:2008+AMD2:2015 CSV | Switches for household and similar fixed electrical installations -Part 2-1: Particular requirements - Electronic switches |
IEC 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
EN 50065-2-2:2003/A1:2005/corrigendum Oct. 2006 | SIGNALING ON LOW-VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148,5 KHZ - PART 2-2: IMMUNITY REQUIREMENTS FOR MAINS COMMUNICATIONS EQUIPMENT AND SYSTEMS OPERATING IN THE RANGE OF FREQUENCIES 95 KHZ TO 148,5 KHZ AND INTENDED FOR USE IN INDUSTRIAL ENVIRONMENTS |
EN 50065-2-1 : 2003 AMD 1 2005 | SIGNALLING ON LOW-VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148,5 KHZ - PART 2-1: IMMUNITY REQUIREMENTS FOR MAINS COMMUNICATIONS EQUIPMENT AND SYSTEMS OPERATING IN THE RANGE OF FREQUENCIES 95 KHZ TO 148,5 KHZ AND INTENDED FOR USE IN RESIDENTIAL, COMMERCIAL AND LIGHT INDUSTRIAL ENVIRONMENTS |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
EN 301 489-3 : 1.6.1 | ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); ELECTROMAGNETIC COMPATIBILITY (EMC) STANDARD FOR RADIO EQUIPMENT AND SERVICES; PART 3: SPECIFIC CONDITIONS FOR SHORT-RANGE DEVICES (SRD) OPERATING ON FREQUENCIES BETWEEN 9 KHZ AND 246 GHZ |
CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
EN 50090-2-2:1996/A2:2007 | HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) - PART 2-2: SYSTEM OVERVIEW - GENERAL TECHNICAL REQUIREMENTS |
IEC 61000-6-3:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments |
IEC 60715:2017 | Dimensions of low-voltage switchgear and controlgear - Standardized mounting on rails for mechanical support of switchgear, controlgear and accessories |
IEC 61058-1:2016 | Switches for appliances - Part 1: General requirements |
IEC 61000-4-20:2010 | Electromagnetic compatibility (EMC) - Part 4-20: Testing and measurement techniques - Emission and immunity testing in transverse electromagnetic (TEM) waveguides |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 60669-1:2017 | Switches for household and similar fixed-electrical installations - Part 1: General requirements |
IEC 61000-2-2:2002+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems |
IEC 61000-3-3:2013 RLV | Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection |
EN 300 220-2 : 2.4.1 | SHORT RANGE DEVICES (SRD) OPERATING IN THE FREQUENCY RANGE 25 MHZ TO 1 000 MHZ - PART 2: HARMONISED STANDARD FOR ACCESS TO RADIO SPECTRUM FOR NON SPECIFIC RADIO EQUIPMENT |
IEC 60664-3:2016 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
EN 50065-1:2011 | Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz - Part 1: General requirements, frequency bands and electromagnetic disturbances |
EN 50065-2-3 : 2003 AMD 1 2005 | SIGNALLING ON LOW-VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148.5 KHZ - PART 2-3: IMMUNITY REQUIREMENTS FOR MAINS COMMUNICATIONS EQUIPMENT AND SYSTEMS OPERATING IN THE RANGE OF FREQUENCIES 3 KHZ TO 95 KHZ AND INTENDED FOR USE BY ELECTRICITY SUPPLIERS AND DISTRIBUTORS |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
EN 60670-1:2005/A1:2013 | BOXES AND ENCLOSURES FOR ELECTRICAL ACCESSORIES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS - PART 1: GENERAL REQUIREMENTS (IEC 60670-1:2002/A1:2011, MODIFIED) |
EN 300 220-1 : 2.4.1 | SHORT RANGE DEVICES (SRD) OPERATING IN THE FREQUENCY RANGE 25 MHZ TO 1000 MHZ; PART 1: TECHNICAL CHARACTERISTICS AND METHODS OF MEASUREMENT |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60990:2016 | Methods of measurement of touch current and protective conductor current |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.