IEC 60660:1999
Current
The latest, up-to-date edition.
Insulators - Tests on indoor post insulators of organic material for systems with nominal voltages greater than 1 000 V up to but not including 300 kV
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French, Spanish, Castilian
29-10-1999
Foreword
1 General
1.1 Scope and Object
1.2 Normative References
1.3 Definitions
1.4 Values which characterise a post insulator of
organic material
1.5 Documentation
1.6 Normal Service Conditions
2 General Requirements for Tests
2.1 Classification of Tests
2.2 Quality Assurance
2.3 General Requirements for Electrical Tests
2.4 Lightning Impulse Voltage Tests
2.5 Power-Frequency Voltage Tests
2.6 Standard Reference Atmospheric Conditions for
Tests
2.7 Correction Factors for Atmospheric Conditions
3 Type Tests
3.1 General
3.2 General Requirements for Electrical Type Tests
3.3 Dry Lightning Impulse Withstand Voltage Test
3.4 Dry Power-Frequency Withstand Voltage Test
3.5 Partial Discharge Extinction Voltage Test
3.6 Lightning Impulse Puncture Test
3.7 Mechanical Failing Load Test
3.8 Test for Deflection Under Load at Normal Ambient
Temperature Conditions
3.9 Test for Mechanical bending strength as a
function of temperature
3.10 Water Absorption Test
3.11 Ageing and Humidity Test
3.12 Flammability Test
3.13 Temperature Cycle Test
4 Sample Tests
4.1 General
4.2 Verification of Dimensions
4.3 Re-Test Procedure
5 Routine Tests
5.1 General
5.2 Visual Examination
5.3 Mechanical Routine Test
5.4 Electrical Routine Test and Partial Discharge
Measurement
Annex A (informative) Tolerances of Form and Position
Applicable to post insulators of organic material for indoor service in electrical installations or equipment operating in air at atmospheric pressure on alternating current with a nominal voltage greater than 1 000 V up, but not including, 300 kV, as defined by range I of IEC 60071-1, and a frequency not greater than 100 Hz. Composite insulators are not covered by this standard.
Committee |
TC 36
|
DevelopmentNote |
Also numbered as BS EN 60660. (10/2005) Stability Date: 2019. (09/2017)
|
DocumentType |
Standard
|
Pages |
51
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NF EN 60660 : 2000 | Identical |
NEN EN IEC 60660 : 2000 | Identical |
NEN 10660 : 1982 | Identical |
I.S. EN 60660:2000 | Identical |
PN EN 60660 : 2002 | Identical |
SN EN 60660 : 1999 | Identical |
VDE 0441-3 : 2000-12 | Identical |
DIN EN 60660 : 2000 | Identical |
DIN IEC 60660 : 2000 | Identical |
UNE 21138:1985 | Identical |
CEI EN 60660 : 2000 | Identical |
EN 60660:1999 | Identical |
NFC 66 082 : 1998 | Identical |
UNE-EN 60660:2001 | Identical |
IS 9431 : 2024 | Identical |
UNE-EN 50124-1:2017 | Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment |
BS EN 50119 : 2009 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
BS EN 61869-1:2009 | Instrument transformers General requirements |
13/30281408 DC : 0 | BS EN 61869-10 - INSTRUMENT TRANSFORMERS - PART 10: ADDITIONAL REQUIREMENTS FOR LOW-POWER, STAND-ALONE CURRENT SENSORS |
15/30298489 DC : 0 | BS EN 50124-1 - RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 1: BASIC REQUIREMENTS - CLEARANCES AND CREEPAGE DISTANCES FOR ALL ELECTRICAL AND ELECTRONIC EQUIPMENT |
PREN 50119 : DRAFT 2017 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
IEC TS 61462:1998 | Composite insulators - Hollow insulators for use in outdoor and indoor electrical equipment - Definitions, test methods, acceptance criteria and design recommendations |
IEC 62497-1:2010+AMD1:2013 CSV | Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electricaland electronic equipment |
07/30167174 DC : 0 | BS EN 61869-2 - INSTRUMENT TRANSFORMERS - PART 2: SPECIFIC REQUIREMENT FOR CURRENT TRANSFORMERS |
11/30215604 DC : 0 | BS IEC 60913 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
07/30167396 DC : 0 | BS EN 61869-4 - INSTRUMENT TRANSFORMERS - PART 4 - SPECIFIC REQUIREMENT FOR COMBINED TRANSFORMERS |
PREN 50124-1 : DRAFT 2015 | RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 1: BASIC REQUIREMENTS - CLEARANCES AND CREEPAGE DISTANCES FOR ALL ELECTRICAL AND ELECTRONIC EQUIPMENT |
EN 50124-1:2017 | Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment |
I.S. EN 50124-1:2017 | RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 1: BASIC REQUIREMENTS - CLEARANCES AND CREEPAGE DISTANCES FOR ALL ELECTRICAL AND ELECTRONIC EQUIPMENT |
I.S. EN 50119:2009 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
IEC 62689-1:2016 | Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 1: General principles and requirements |
VDE 0674-1 : 2001-12 | TESTS ON INDOOR AND OUTDOOR POST INSULATORS OF CERAMIC MATERIAL OR GLASS FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1 KV |
DIN EN 60168 : 2001-12 | TESTS ON INDOOR AND OUTDOOR POST INSULATORS OF CERAMIC MATERIAL OR GLASS FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1 KV |
BS 3297-2:1993 | Characteristics of indoor and outdoor post insulators for systems with nominal voltages greater than 1000 V |
14/30284930 DC : 0 | BS EN 62689-2 ED 1.0 - CURRENT AND VOLTAGE SENSORS OR DETECTORS TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 2: GENERAL PRINCIPLES AND REQUIREMENTS |
I.S. EN 61869-1:2009 | INSTRUMENT TRANSFORMERS - PART 1: GENERAL REQUIREMENTS |
CSA C61869-1 : 2014 | INSTRUMENT TRANSFORMERS - PART 1: GENERAL REQUIREMENTS |
UNE-EN 61869-1:2010 | Instrument transformers -- Part 1: General requirements |
EN 62689-1:2016 | Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 1: General principles and requirements |
17/30341013 DC : DRAFT AUG 2017 | BS EN 50119 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
BS EN 62689-1:2016 | Current and voltage sensors or detectors, to be used for fault passage indication purposes General principles and requirements |
I.S. EN 62689-1:2016 | CURRENT AND VOLTAGE SENSORS OR DETECTORS, TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 1: GENERAL PRINCIPLES AND REQUIREMENTS |
IEC 60913:2013 | Railway applications - Fixed installations - Electric traction overhead contact lines |
I.S. EN 50119:2020 | Railway applications - Fixed installations - Electric traction overhead contact lines |
EN 50119 : 2009 AMD 1 2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
12/30268049 DC : 0 | BS EN 62689-1 - CURRENT AND VOLTAGE SENSORS OR DETECTORS, TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 1: GENERAL PRINCIPLES AND REQUIREMENTS |
BS EN 50124-1:2017 | Railway applications. Insulation coordination Basic requirements. Clearances and creepage distances for all electrical and electronic equipment |
CEI EN 61869-1 : 2010 | INSTRUMENT TRANSFORMERS - PART 1: GENERAL REQUIREMENTS |
IEC 61869-1:2007 | Instrument transformers - Part 1: General requirements |
EN 61869-1:2009 | Instrument transformers - Part 1: General requirements |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
IEC 60050-471:2007 | International Electrotechnical Vocabulary (IEV) - Part 471: Insulators |
ISO 9002:1994 | Quality systems — Model for quality assurance in production, installation and servicing |
IEC 60273:1990 | Characteristic of indoor and outdoor post insulators for systems with nominal voltages greater than 1000 V |
IEC 60695-11-10:2013 | Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods |
IEC 60587:2007 | Electrical insulating materials used under severe ambient conditions - Test methods for evaluating resistance to tracking and erosion |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
ISO 9000-1:1994 | Quality management and quality assurance standards — Part 1: Guidelines for selection and use |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.