IEC 60623:2017
Current
The latest, up-to-date edition.
Secondary cells and batteries containing alkaline or other non-acid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
23-01-2017
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Parameter measurement tolerances
5 Designation and marking
6 Dimensions
7 Electrical tests
8 Mechanical tests
9 Physical appearance
10 Conditions for approval and acceptance
Annex A (normative) - CCCV charge methodology
Bibliography
IEC 60623:2017 specifies marking, designation, dimensions, tests and requirements for vented nickel-cadmium prismatic secondary single cells. When there exists an IEC standard specifying test conditions and requirements for cells used in special applications and which is in conflict with this document, the former takes precedence.
This edition includes the following significant technical changes with respect to the previous edition:
- optional characterization of cells designed for performances at very low and/or very high temperature;
- optional characterization of cells tested with CCCV charge;
- optional characterization of cells designed for rapid charge;
- optional characterization of cells designed for high cycling.
Committee |
TC 21/SC 21A
|
DevelopmentNote |
Stability Date: 2019. (01/2017)
|
DocumentType |
Standard
|
Pages |
48
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NF EN 60623 : 2017 | Identical |
NEN EN IEC 60623 : 2017 | Identical |
PN EN 60623 : 2017 | Identical |
SN EN 60623 : 2017 | Identical |
BS EN 60623:2017 | Identical |
CEI EN 60623 : 2002 | Identical |
EN 60623:2017 | Identical |
DIN EN 60623:2014-04 (Draft) | Identical |
CEI EN 60623:2021 | Identical |
NEN 10623 : 1996 | Identical |
UNE-EN 60623:2017 | Identical |
DIN 43539-14:1985-01 | Identical |
BS 6260:1982 | Similar to |
UNE-EN 60623:2002 | Identical |
UNE EN 60623 : 2002 | Identical |
PNE-FprEN 60623 | Identical |
GOST R IEC 60623 : 2008 | Identical |
BS EN 60079-7 : 2015 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015) |
BS EN 61427-2:2015 | Secondary cells and batteries for renewable energy storage. General requirements and methods of test On-grid applications |
12/30243533 DC : 0 | BS EN 61427-2 ED 1.0 - SECONDARY CELLS AND BATTERIES FOR RENEWABLE ENERGY STORAGE - GENERAL REQUIREMENTS AND METHODS OF TEST - PART 2: ON-GRID APPLICATIONS |
PREN 50547 : DRAFT 2011 | RAILWAY APPLICATIONS - BATTERIES FOR AUXILIARY POWER SUPPLY SYSTEMS |
17/30339497 DC : DRAFT JUNE 2017 | BS EN 14972 - FIXED FIREFIGHTING SYSTEMS - WATER MIST SYSTEMS - PART 1: DESIGN, INSTALLATION, INSPECTION AND MAINTENANCE |
BS EN 61241-0:2006 | Electrical apparatus for use in the presence of combustible dust General requirements |
11/30243529 DC : 0 | BS EN 61427-1 ED1 - SECONDARY CELLS AND BATTERIES FOR RENEWABLE ENERGY STORAGE - GENERAL REQUIREMENTS AND METHODS OF TEST - PART 1: PHOTOVOLTAIC OFF GRID APPLICATION |
CEI EN 62259 : 2005 | SECONDARY CELLS AND BATTERIES CONTAINING ALKALINE OR OTHER NON-ACID ELECTROLYTES - NICKEL-CADMIUM PRISMATIC SECONDARY SINGLE CELLS WITH PARTIAL GAS RECOMBINATION |
94/712993 DC : DRAFT NOV 1994 | PREN 45511 - GUIDE FOR PROCUREMENT - ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
CSA C22.2 No. 60079.1 : 2016 | EXPLOSIVE ATMOSPHERES - PART 1: EQUIPMENT PROTECTION BY FLAMEPROOF ENCLOSURES 'D' |
UNE-EN 50272-1:2011 | Safety requirements for secondary batteries and battery installations - Part 1: General safety information |
BS IEC 61892-6:2013 | Mobile and fixed offshore units. Electrical installations Installation |
BS EN 62259:2004 | Secondary cells and batteries containing alkaline or other non-acid electrolytes. Nickel-cadmium prismatic secondary single cells with partial gas recombination |
I.S. HD 60364-5-56:2010 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-56: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SAFETY SERVICES (IEC 60364-5-56:2009 (EQV)) |
UNE-EN 50547:2013 | Railway applications - Batteries for auxiliary power supply systems |
I.S. EN 60079-1:2014 | EXPLOSIVE ATMOSPHERES - PART 1: EQUIPMENT PROTECTION BY FLAMEPROOF ENCLOSURES 'D' |
I.S. EN 61427:2005 | SECONDARY CELLS AND BATTERIES FOR PHOTOVOLTAIC ENERGY SYSTEMS (PVES) - GENERAL REQUIREMENTS AND METHODS OF TEST |
BS EN 50019:2000 | Electrical apparatus for potentially explosive atmospheres. Increased safety \'e\' |
DIN EN 12845:2016-04 | FIXED FIREFIGHTING SYSTEMS - AUTOMATIC SPRINKLER SYSTEMS - DESIGN, INSTALLATION AND MAINTENANCE |
S.R. HD 60364-5-56:2010 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-56: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SAFETY SERVICES |
I.S. EN IEC 62485-1:2018 | SAFETY REQUIREMENTS FOR SECONDARY BATTERIES AND BATTERY INSTALLATIONS - PART 1: GENERAL SAFETY INFORMATION |
IEC 60079-7:2015+AMD1:2017 CSV | Explosive atmospheres - Part 7: Equipment protection by increased safety "e" |
EN IEC 60079-7:2015/A1:2018 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015/A1:2017) |
BS EN 50272-1:2010 | Safety requirements for secondary batteries and battery installations General safety information |
EN 50272-1:2010 | Safety requirements for secondary batteries and battery installations - Part 1: General safety information |
EN 62259:2004 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Nickel-cadmium prismatic secondary single cells with partial gas recombination |
EN IEC 62485-2:2018 | Safety requirements for secondary batteries and battery installations - Part 2: Stationary batteries |
EN 61427-1 : 2013 | SECONDARY CELLS AND BATTERIES FOR RENEWABLE ENERGY STORAGE - GENERAL REQUIREMENTS AND METHODS OF TEST - PART 1: PHOTOVOLTAIC OFF-GRID APPLICATION (IEC 61427-1:2013) |
EN 61427:2005 | Secondary cells and batteries for photovoltaic energy systems (PVES) - General requirements and methods of test |
NBR IEC 60079-0 : 2013 ERRATA 2 2016 | EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS |
NF EN 50547 : 2013 | RAILWAY APPLICATIONS - BATTERIES FOR AUXILIARY POWER SUPPLY SYSTEMS |
BS EN 45510-2-7:2002 | Guide for the procurement of power station equipment. Electrical equipment Switchgear and controlgear |
UNE-EN 61427-1:2013 | Secondary cells and batteries for renewable energy storage - General requirements and methods of test - Part 1: Photovoltaic off-grid application |
CEI UNI EN 45510-2-7 : 2006 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
I.S. EN 61427-1:2013 | SECONDARY CELLS AND BATTERIES FOR RENEWABLE ENERGY STORAGE - GENERAL REQUIREMENTS AND METHODS OF TEST - PART 1: PHOTOVOLTAIC OFF-GRID APPLICATION (IEC 61427-1:2013 (EQV)) |
ISO 8528-12:1997 | Reciprocating internal combustion engine driven alternating current generating sets — Part 12: Emergency power supply to safety services |
CSA C22.2 No. 60079-7 : 2016 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' |
I.S. EN IEC 62485-2:2018 | SAFETY REQUIREMENTS FOR SECONDARY BATTERIES AND BATTERY INSTALLATIONS - PART 2: STATIONARY BATTERIES |
BS EN 12845:2015 | Fixed firefighting systems. Automatic sprinkler systems. Design, installation and maintenance |
IEC 60079-1:2014 RLV | Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" |
UNE-HD 60364-5-56:2010 | Low-voltage electrical installations - Part 5-56: Selection and erection of electrical equipment - Safety services |
09/30206527 DC : 0 | BS EN 60079-0 ED 6.0 - EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS |
BIS IS/IEC 60079-0 : 2011 | EXPLOSIVE ATMOSPHERES - PART 0: GENERAL REQUIREMENTS |
ISA 60079-7 : 2008 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY "E" |
ISA 61241-0 : 2006 | ELECTRICAL APPARATUS FOR USE IN ZONE 20, ZONE 21 AND ZONE 22 HAZARDOUS (CLASSIFIED) LOCATIONS - GENERAL REQUIREMENTS |
11/30235301 DC : 0 | BS EN 50547 - RAILWAY APPLICATIONS - BATTERIES FOR AUXILIARY POWER SUPPLY SYSTEMS |
BS EN 50018:2000 | Electrical apparatus for potentially explosive atmospheres. Flameproof enclosure \'d\' |
BS 7698-12:1998 | Reciprocating internal combustion engine driven alternating current generating sets Emergency power supply to safety devices |
02/208499 DC : DRAFT AUG 2002 | |
14/30278882 DC : 0 | BS EN 60079-7 IEC 60079-7 ED. 5.0 - EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' |
04/30113660 DC : DRAFT MAY 2004 | IEC 60079-7 - ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 7: INCREASED SAFETY 'E' |
BS 6260:1982 | Specification for open nickel-cadmium prismatic rechargeable single cells |
DIN 40771-1:2013-01 | VENTED NICKEL-CADMIUM-ACCUMULATORS - PART 1: CELLS IN PLASTIC CONTAINERS WITH POCKET TYPE PLATES - RATED CAPACITIES - MAIN DIMENSIONS |
IEEE 1568 : 2003 | RECOMMENDED PRACTICE FOR ELECTRICAL SIZING OF NICKEL-CADMIUM BATTERIES FOR RAIL PASSENGER VEHICLES |
CAN/CSA-C61427-1:17 | Secondary cells and batteries for renewable energy storage — General requirements and methods of test — Part 1: Photovoltaic off-grid application (Adopted IEC 61427-1:2013, first edition, 2013-04, with Canadian deviations) | Accumulateurs pour le stockage de l’énergie renouvelable — Exigences générales et méthodes d’essais — Partie 1 : Applications photovoltaïques hors réseaux (norme IEC 61427-1:2013 adoptée, première édition, 2013-04, avec exigences propres au Canada) |
I.S. EN 60079-7:2015 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' |
I.S. EN 50272-1:2010 | SAFETY REQUIREMENTS FOR SECONDARY BATTERIES AND BATTERY INSTALLATIONS - PART 1: GENERAL SAFETY INFORMATION |
BS 6115:1981 | Specification for sealed nickel-cadmium prismatic rechargeable single cells |
IEC 61241-0:2004 | Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements |
IEC 62485-2:2010 | Safety requirements for secondary batteries and battery installations - Part 2: Stationary batteries |
12/30261012 DC : 0 | BS IEC 61892-6 - MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 6: INSTALLATION |
CEI EN 50272-2 : 2002 | SAFETY REQUIREMENTS FOR SECONDARY BATTERIES AND BATTERY INSTALLATIONS - PART 2: STATIONARY BATTERIES |
CSA C22.2 No. 60079.1 : 2016 | EXPLOSIVE ATMOSPHERES - PART 1: EQUIPMENT PROTECTION BY FLAMEPROOF ENCLOSURES 'D' |
IEEE 1536 : 2002 | RAIL TRANSIT VEHICLE BATTERY PHYSICAL INTERFACE |
03/300201 DC : DRAFT FEB 2003 | IEC 60079-0 ED.4.0 - ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 0: GENERAL REQUIREMENTS |
BS EN 50547:2013 | Railway applications. Batteries for auxiliary power supply systems |
03/119704 DC : DRAFT DEC 2003 | IEC 61427 ED.2 - SECONDARY CELLS AND BATTERIES FOR SOLAR PHOTOVOLTAIC ENERGY SYSTEMS - GENERAL REQUIREMENTS AND METHODS OF TEST |
BS EN 61427-1:2013 | Secondary cells and batteries for renewable energy storage. General requirements and methods of test Photovoltaic off-grid application |
97/541589 DC : DRAFT MAY 1997 | PREN 12845 - FIXED FIREFIGHTING SYSTEMS - AUTOMATIC SPRINKLER SYSTEMS - DESIGN AND INSTALLATION |
I.S. EN 61427-2:2015 | SECONDARY CELLS AND BATTERIES FOR RENEWABLE ENERGY STORAGE - GENERAL REQUIREMENTS AND METHODS OF TEST - PART 2: ON-GRID APPLICATIONS |
CEI EN 50547 : 2014 | RAILWAY APPLICATIONS - BATTERIES FOR AUXILIARY POWER SUPPLY SYSTEMS |
IEEE 1115-2014 | IEEE Recommended Practice for Sizing Nickel-Cadmium Batteries for Stationary Applications |
UNI CEI EN 45510-2-7 : 2011 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
PREN 14972-1 : DRAFT 2017 | FIXED FIREFIGHTING SYSTEMS - WATER MIST SYSTEMS - PART 1: DESIGN, INSTALLATION, INSPECTION AND MAINTENANCE |
GOST R ISO 8528-12 : 2005 | RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN ALTERNATING CURRENT GENERATING SETS - PART 12: EMERGENCY POWER SUPPLY TO SAFETY SERVICES |
IEC 60079-0:2017 | Explosive atmospheres - Part 0: Equipment - General requirements |
UNE-EN 60079-7:2016 | Explosive atmospheres - Part 7: Equipment protection by increased safety "e" |
IEC 61892-6:2013 | Mobile and fixed offshore units - Electrical installations - Part 6: Installation |
CEI EN 61427-1 : 2014 | SECONDARY CELLS AND BATTERIES FOR RENEWABLE ENERGY STORAGE - GENERAL REQUIREMENTS AND METHODS OF TEST - PART 1: PHOTOVOLTAIC OFF-GRID APPLICATION |
I.S. EN 61241-0:2006 | ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 0: GENERAL REQUIREMENTS |
IEC 60079-0:2017 RLV | Explosive atmospheres - Part 0: Equipment - General requirements |
IEC 61427:2005 | Secondary cells and batteries for photovoltaic energy systems (PVES) - General requirements and methods of test |
UNE-EN 60079-0:2013 | Explosive atmospheres - Part 0: Equipment - General requirements |
IEC 61427-1:2013 | Secondary cells and batteries for renewable energy storage - General requirements and methods of test - Part 1: Photovoltaic off-grid application |
05/30134569 DC : DRAFT JUN 2005 | IEC 60079-0. ED. 5.0 - ELECTRICAL APPARATUS FOR EXPLOSIVE ATMOSPHERES - PART 0: GENERAL REQUIREMENTS |
IEC 61427-2:2015 | Secondary cells and batteries for renewable energy storage - General requirements and methods of test - Part 2: On-grid applications |
ISA 60079-1 : 2005 | EXPLOSIVE ATMOSPHERES - PART 1: EQUIPMENT PROTECTION BY FLAMEPROOF ENCLOSURES "D" |
EI Model code of safe practice Part 15:2015 | MODEL CODE OF SAFE PRACTICE - PART 15: AREA CLASSIFICATION FOR INSTALLATIONS HANDLING FLAMMABLE FLUIDS |
EI MODEL CODE SAFE PRACTICE PT1 : 2010 | THE SELECTION, INSTALLATION, INSPECTION, AND MAINTENANCE OF ELECTRICAL AND NON ELECTRICAL APPARATUS IN HAZARDOUS AREAS |
EN 45510-2-7:2002 | Guide for procurement of power station equipment - Part 2-7: Electrical equipment - Switchgear and controlgear |
UNE-EN 60079-1:2015 | Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" |
I.S. EN 12845:2015 | FIXED FIREFIGHTING SYSTEMS - AUTOMATIC SPRINKLER SYSTEMS - DESIGN, INSTALLATION AND MAINTENANCE |
BS EN 61427:2005 | Secondary cells and batteries for photovoltaic energy systems (PVES). General requirements and methods of test |
11/30247086 DC : 0 | BS EN 60079-1 ED. 7.0 - EXPLOSIVE ATMOSPHERES - PART 1: EQUIPMENT PROTECTION BY FLAMEPROOF ENCLOSURES "D" |
CSA E60079.7 : 2003 | ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 7: INCREASED SAFETY "E" |
HD 60364-5-56:2010/A12:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-56: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SAFETY SERVICES |
BIS IS/IEC 60079-1 : 2007 | EXPLOSIVE ATMOSPHERES - PART 1: EQUIPMENT PROTECTION BY FLAMEPROOF ENCLOSURES 'D' |
BIS IS/IEC 60079-7 : 2006 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' |
I.S. EN 50547:2013 | RAILWAY APPLICATIONS - BATTERIES FOR AUXILIARY POWER SUPPLY SYSTEMS |
IEEE 1106-2015 | IEEE Recommended Practice for Installation, Maintenance, Testing, and Replacement of Vented Nickel-Cadmium Batteries for Stationary Applications |
CEI UNI EN 45510-2-2 : 1999 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-2: ELECTRICAL EQUIPMENT - UNINTERRUPTIBLE POWER SUPPLIES |
I.S. EN 62259:2004 | SECONDARY CELLS AND BATTERIES CONTAINING ALKALINE OR OTHER NON-ACID ELECTROLYTES - NICKEL-CADMIUM PRISMATIC SECONDARY SINGLE CELLS WITH PARTIAL GAS RECOMBINATION |
BS EN 60079-0 : 2012 | EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS |
UNE-EN 12845:2016 | Fixed firefighting systems - Automatic sprinkler systems - Design, installation and maintenance |
IEC 60364-5-56:2009 | Low-voltage electrical installations - Part 5-56: Selection and erection of electrical equipment - Safety services |
I.S. EN 50019:2001 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INCREASED SAFETY "E" |
I.S. EN 60079-0:2012 | EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011 (MOD)) |
BS EN 45510-2-2:1999 | Guide for the procurement of power station equipment. Electrical equipment Uninterruptible power supplies - Uninterruptible power supplies for power plants |
13/30286778 DC : 0 | BS EN 60079-1 - EXPLOSIVE ATMOSPHERES - PART 1: EQUIPMENT PROTECTION BY FLAMEPROOF ENCLOSURES 'D' |
IEC 62259:2003 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Nickel-cadmium prismatic secondary single cells with partial gas recombination |
EN 60079-0:2012/A11:2013 | EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED) |
EN 50547:2013 | Railway applications - Batteries for auxiliary power supply systems |
EN 50018 : 2000 AMD 1 2002 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - FLAMEPROOF ENCLOSURE "D" |
EN 60079-1:2014 | Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" |
EN 50019:2000/corrigendum Apr. 2003 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INCREASED SAFETY "E" |
EN IEC 62485-1:2018 | Safety requirements for secondary batteries and battery installations - Part 1: General safety information |
EN 61427-2:2015 | Secondary cells and batteries for renewable energy storage - General requirements and methods of test - Part 2: On-grid applications |
EN 61241-0:2006 | Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements |
CSA C22.2 No. 60079.0 : 2015 | EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS |
IEC TR 61438:1996 | Possible safety and health hazards in the use of alkaline secondary cells and batteries - Guide to equipment manufacturers and users |
IEC 60485:1974 | Digital electronic d.c. voltmeters and d.c. electronic analogue-to-digital converters |
IEC 60050-482:2004 | International Electrotechnical Vocabulary (IEV) - Part 482: Primary and secondary cells and batteries |
IEC 60410:1973 | Sampling plans and procedures for inspection by attributes |
IEC 61434:1996 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Guide to designation of current in alkaline secondary cell and battery standards |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.