IEC 60603-7-3:2010
Current
The latest, up-to-date edition.
Connectors for electronic equipment - Part 7-3: Detail specification for 8-way, shielded, free and fixed connectors, for data transmission with frequencies up to 100 MHz
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
26-04-2010
FOREWORD
INTRODUCTION
1 General
2 Terms and definitions
3 Common features and isometric view
4 Cable terminations and internal connections - Fixed and
free connectors
5 Gauges
6 Characteristics
7 Tests and test schedule
Bibliography
IEC 60603-7-3:2010 covers 8-way, shielded, free and fixed connectors, references dimensional, mechanical, electrical and environmental characteristics and tests in IEC 60603-7 and IEC 60603-7-1, and specifies electrical transmission requirements for frequencies up to 100 MHz. These connectors are typically used as category 5 connectors in class D cabling systems specified in ISO/IEC 11801. These connectors are intermateable and interoperable with other IEC 60603-7 series connectors as defined in Clause 2 of IEC 60603-7. These connectors are backward compatible with other IEC 60603-7 series connectors.
Committee |
TC 48/SC 48B
|
DevelopmentNote |
Supersedes IEC PAS 60603-7-3. (02/2008) Stability Date: 2017. (10/2012)
|
DocumentType |
Standard
|
Pages |
25
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NBN EN 60603-7-3 : DEC 2010 | Identical |
NEN EN IEC 60603-7-3 : 2010 | Identical |
DIN EN 60603-7-3 : 2011 | Identical |
VDE 0687-603-7-3 : 2011 | Identical |
CEI EN 60603-7-3 : 2011 | Identical |
NF EN 60603-7-3 : DEC 2010 | Identical |
PN EN 60603-7-3 : NOV 2010 | Identical |
PNE-FprEN 60603-7-3 | Identical |
UNE-EN 60603-7-3:2010 | Identical |
EN 60603-7-3:2010 | Identical |
BS EN 60603-7-3:2010 | Identical |
I.S. EN 60603-7-3:2010 | Identical |
13/30279981 DC : 0 | BS EN 50599 - BALANCED COMMUNICATION CABLING IN ACCORDANCE WITH EN 50173-4 SCREENED STRAIGHT PATCH CORDS AND STRAIGHT WORK AREA CORDS FOR CLASS D APPLICATIONS - DETAIL SPECIFICATION |
BS ISO/IEC 11801-1:2017 | Information technology. Generic cabling for customer premises General requirements |
BS EN 61076-3-115:2010 | Connectors for electronic equipment. Product requirements Rectangular connectors. Detail specification for protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface. Variant 12 related to IEC 61076-3-106. Push-pull type |
CEI EN 61076-3-116 : 2010 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-116: RECTANGULAR CONNECTORS - PROTECTIVE HOUSINGS FOR USE WITH 8- WAY SHIELDED AND UNSHIELDED CONNECTORS FOR FREQUENCIES UP TO 600 MHZ FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE - VARIANT 13 RELATED TO IEC 61076-3-106 - LOCKING LEVER |
BS EN 50599:2014 | Generic cabling systems. Specification for the testing of balanced communication cabling in accordance with EN 50173-4. Screened straight patch cords and straight work area cords for class D applications. Detail specification |
NF EN 61076-3-114 : 2010 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-114: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR FREQUENCIES UP TO 600 MHZ FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE - VARIANT 11 RELATED TO IEC 61076-3-106 - BAYONET COUPLING TYPE |
CSA ISO/IEC 15018 : 2005 : R2010 | INFORMATION TECHNOLOGY - GENERIC CABLING FOR HOMES |
CSA ISO/IEC 15018:2005 | INFORMATION TECHNOLOGY - GENERIC CABLING FOR HOMES |
CSA ISO/IEC 15018 : 2005 : INC : AMD 1 : 2010 : R201000 | INFORMATION TECHNOLOGY - GENERIC CABLING FOR HOMES |
I.S. EN 61935-2-20:2009 | TESTING OF BALANCED COMMUNICATION CABLING IN ACCORDANCE WITH SERIES EN 50173 - PART 2-20: PATCH CORDS AND WORK AREA CORDS - BLANK DETAIL SPECIFICATION FOR CLASS D APPLICATIONS |
I.S. EN 61076-3-116:2008 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-116: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR FREQUENCIES UP TO 600 MHZ FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE - VARIANT 13 RELATED TO IEC 61076-3-106 - LOCKING LEVER |
I.S. EN 61784-5-2:2013 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 5-2: INSTALLATION OF FIELDBUSES - INSTALLATION PROFILES FOR CPF 2 |
NF EN 60512-26-100 : 2009 AMD 1 2011 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 26-100: MEASUREMENT SETUP, TEST AND REFERENCE ARRANGEMENTS AND MEASUREMENTS FOR CONNECTORS ACCORDING TO IEC 60603-7 - TESTS 26A TO 26G |
IEC PAS 61076-3-117:2006 | Connectors for electronic equipment - Product requirements - Part 3-117: Rectangular connectors - Protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating IEC 60603-7 - Variant 14 related to IEC 61076-3-106 - Push-pull coupling |
EN 60603-7-81:2016/AC:2017-07 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-81: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSIONS WITH FREQUENCIES UP TO 2000 MHZ (IEC 60603-7-81:2015/COR 1:2017) |
EN 61076-3-114 : 2009 | Connectors for electronic equipment - Product requirements - Part 3-114: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface - Variant 11 related to IEC 61076-3-106 - Bayonet coupling type |
EN 61076-3-116 : 2008 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-116: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR FREQUENCIES UP TO 600 MHZ FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE - VARIANT 13 RELATED TO IEC 61076-3-106 - LOCKING LEVER |
BS EN 60512-26-100 : 2008 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 26-100: MEASUREMENT SETUP, TEST AND REFERENCE ARRANGEMENTS AND MEASUREMENTS FOR CONNECTORS ACCORDING TO IEC 60603-7 - TESTS 26A TO 26G |
CLC/TR 50173-99-3:2012 | Information technology - Generic cabling systems - Part 99-3: Home cabling infrastructures up to 50 m in length to support simultaneous and non simultaneous provision of applications |
CEI EN 50173-1 : 2011 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 1: GENERAL REQUIREMENTS |
I.S. EN 61784-5-12:2012 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 5-12: INSTALLATION OF FIELDBUSES - INSTALLATION PROFILES FOR CPF 12 (IEC 61784-5-12:2010) |
BS EN 61076-3-116:2008 | Connectors for electronic equipment. Product requirements Rectangular connectors. Detail specification for protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface. Variant 13 related to IEC 61076-3-106. Locking lever |
I.S. EN 61076-3-115:2010 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-115: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR FREQUENCIES UP TO 600 MHZ FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE - VARIANT 12 RELATED TO IEC 61076-3-106 - PUSH-PULL TYPE |
BS EN 60603-7 : 2009 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7: DETAIL SPECIFICATION FOR 8-WAY, UNSHIELDED, FREE AND FIXED CONNECTORS |
EN 50173-1:2011 | Information technology - Generic cabling systems - Part 1: General requirements |
EN 60603-7:2009/A1:2011 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7: DETAIL SPECIFICATION FOR 8-WAY, UNSHIELDED, FREE AND FIXED CONNECTORS (IEC 60603-7:2008/A1:2011) |
I.S. EN 50173-1:2011 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 1: GENERAL REQUIREMENTS |
CEI CLC/TR 50173-99-3 : 2013 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 99-3: HOME CABLING INFRASTRUCTURES UP TO 50 M IN LENGTH TO SUPPORT SIMULTANEOUS AND NON SIMULTANEOUS PROVISION OF APPLICATIONS |
BS EN 60603-7-81:2016 | Connectors for electronic equipment Detail specification for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to 2 000 MHz |
I.S. EN 61784-5-15:2012 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 5-15: INSTALLATION OF FIELDBUSES - INSTALLATION PROFILES FOR CPF 15 |
BS EN 50173-1:2011 | Information technology. Generic cabling systems General requirements |
CEI EN 61935-2-20 : 2011 | TESTING OF BALANCED COMMUNICATION CABLING IN ACCORDANCE WITH SERIES EN 50173 - PART 2-20: PATCH CORDS AND WORK AREA CORDS - BLANK DETAIL SPECIFICATION FOR CLASS D APPLICATIONS |
CEI EN 61076-3-115 : 2012 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-115: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR FREQUENCIES UP TO 600 MHZ FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE - VARIANT 12 RELATED TO IEC 61076-3-106 - PUSH-PULL TYPE |
I.S. EN 50599:2014 | GENERIC CABLING SYSTEMS - SPECIFICATION FOR THE TESTING OF BALANCED COMMUNICATION CABLING IN ACCORDANCE WITH EN 50173-4 - SCREENED STRAIGHT PATCH CORDS AND STRAIGHT WORK AREA CORDS FOR CLASS D APPLICATIONS - DETAIL SPECIFICATION |
16/30346304 DC : 0 | BS EN 61162-450 - MARITIME NAVIGATION AND RADIOCOMMUNICATION EQUIPMENT AND SYSTEMS -DIGITAL INTERFACES - PART 450: MULTIPLE TALKERS AND MULTIPLE LISTENERS - ETHERNET INTERCONNECTION |
ANSI INCITS 435 : 2007 | INFORMATION TECHNOLOGY - FIBRE CHANNEL - BASET (FC-BASET) |
ISO/IEC 14165-151:2017 | Information technology Fibre channel Part 151: Fibre Channel BaseT (FC-BaseT) |
I.S. EN 60603-7-81:2016 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-81: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSIONS WITH FREQUENCIES UP TO 2000 MHZ |
I.S. EN 61162-450:2011 | MARITIME NAVIGATION AND RADIOCOMMUNICATION EQUIPMENT AND SYSTEMS - DIGITAL INTERFACES - PART 450: MULTIPLE TALKERS AND MULTIPLE LISTENERS - ETHERNET INTERCONNECTION (IEC 61162-450:2011/A1:2016) |
BS EN 61784-5-2:2013 | Industrial communication networks. Profiles Installation of fieldbuses. Installation profiles for CPF 2 |
BS EN 61784-5-15 : 2012 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 5-15: INSTALLATION OF FIELDBUSES - INSTALLATION PROFILES FOR CPF 15 |
BS EN 61784-5-12 : 2012 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 5-12: INSTALLATION OF FIELDBUSES - INSTALLATION PROFILES FOR CPF 12 |
S.R. CLC/TR 50173-99-3:2012 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 99-3: HOME CABLING INFRASTRUCTURES UP TO 50 M IN LENGTH TO SUPPORT SIMULTANEOUS AND NON SIMULTANEOUS PROVISION OF APPLICATIONS |
NF EN 61076-3-116 : 2009 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-116: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR FREQUENCIES UP TO 600 MHZ FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE - VARIANT 13 RELATED TO IEC 61076-3-106 - LOCKING LEVER |
ISO/IEC 11801:2002 | Information technology Generic cabling for customer premises |
ISO/IEC 15018:2004 | Information technology Generic cabling for homes |
IEC 61935-2-20:2008 | Testing of balanced communication cabling in accordance with ISO/IEC 11801 - Part 2-20: Patch cords and work area cords - Blank detail specification for class D applications |
IEC 60603-7:2008+AMD1:2011 CSV | Connectors for electronic equipment - Part 7: Detail specification for 8-way, unshielded, free and fixed connectors |
EN 60603-7-82:2016 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-82: DETAIL SPECIFICATION FOR 8-WAY, 12 CONTACTS, SHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSION WITH FREQUENCIES UP TO 2000 MHZ (IEC 60603-7-82:2016) |
CEI EN 50599 : 2014 | GENERIC CABLING SYSTEMS - SPECIFICATION FOR THE TESTING OF BALANCED COMMUNICATION CABLING IN ACCORDANCE WITH EN 50173-4 - SCREENED STRAIGHT PATCH CORDS AND STRAIGHT WORK AREA CORDS FOR CLASS D APPLICATIONS - DETAIL SPECIFICATION |
BS EN 61076-3-114:2009 | Connectors for electronic equipment. Product requirements Rectangular connectors. Detail specification for.protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface. Variant 11 related to IEC 61076-3-106. Bayonet coupling type |
PD CLC/TR 50173-99-3:2012 | Information technology. Generic cabling systems Home cabling infrastructures up to 50 m in length to support simultaneous and non simultaneous provision of applications |
16/30325971 DC : 0 | BS ISO/IEC 11801-1 - INFORMATION TECHNOLOGY - GENERIC CABLING FOR CUSTOMER PREMISES - PART 1: GENERAL REQUIREMENTS |
I.S. EN 60603-7:2009 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7: DETAIL SPECIFICATION FOR 8-WAY, UNSHIELDED, FREE AND FIXED CONNECTORS (IEC 60603-7:2008) |
I.S. EN 60603-7-82:2016 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-82: DETAIL SPECIFICATION FOR 8-WAY, 12 CONTACTS, SHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSION WITH FREQUENCIES UP TO 2000 MHZ |
ISO/IEC 24740:2008 | Information technology Responsive Link (RL) |
I.S. EN 60512-26-100:2008 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 26-100: MEASUREMENT SETUP, TEST AND REFERENCE ARRANGEMENTS AND MEASUREMENTS FOR CONNECTORS ACCORDING TO IEC 60603-7 - TESTS 26A TO 26G |
IEC 61076-3-116:2008 | Connectors for electronic equipment - Product requirements - Part 3-116: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface - Variant 13 related to IEC 61076-3-106 - Locking lever |
IEC 61076-3-114:2009 | Connectors for electronic equipment - Product requirements - Part 3-114: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface - Variant 11 related to IEC 61076-3-106 - Bayonet coupling type |
BS ISO/IEC 14165-151:2017 | Information technology. Fibre channel Fibre Channel BaseT (FC-BaseT) |
IEC 61784-5-12:2010+AMD1:2015 CSV | Industrial communication networks - Profiles - Part 5-12: Installation of fieldbuses - Installation profiles for CPF 12 |
IEC 61784-5-15:2010+AMD1:2015 CSV | Industrial communication networks - Profiles - Part 5-15: Installation of fieldbuses - Installation profiles for CPF 15 |
IEC 61784-5-2:2013 | Industrial communication networks - Profiles - Part 5-2: Installation of fieldbuses - Installation profiles for CPF 2 |
IEC 60512-26-100:2008+AMD1:2011 CSV | Connectors for electronic equipment - Tests and measurements - Part 26-100: Measurement setup, test and reference arrangements and measurements for connectors according to IEC 60603-7 - Tests 26a to 26g |
BS EN 61935-2-20:2009 | Testing of balanced communication cabling in accordance with series EN 50173 Patch cords and work area cords. Blank detail specification for class D applications |
PREN 50599 : DRAFT 2013 | BALANCED COMMUNICATION CABLING IN ACCORDANCE WITH EN 50173-4 SCREENED STRAIGHT PATCH CORDS AND STRAIGHT WORK AREA CORDS FOR CLASS D APPLICATIONS - DETAIL SPECIFICATION |
BS EN 61162-450:2011 | Maritime navigation and radiocommunication equipment and systems. Digital interfaces Multiple talkers and multiple listeners. Ethernet interconnection |
CSA ISO/IEC 15018 : 2005 : INC : AMD 1 : 2010 : R2015 | INFORMATION TECHNOLOGY - GENERIC CABLING FOR HOMES |
BS EN 60603-7-82:2016 | Connectors for electronic equipment Detail specification for 8-way, 12 contacts, shielded, free and fixed connectors, for data transmission with frequencies up to 2 000 MHz |
ISO/IEC 11801-1:2017 | Information technology — Generic cabling for customer premises — Part 1: General requirements |
NF EN 61076-3-115 : 2011 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-115: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR FREQUENCIES UP TO 600 MHZ FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE - VARIANT 12 RELATED TO IEC 61076-3-106 - PUSH-PULL TYPE |
CEI EN 61784-5-2 : 2014 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 5-2: INSTALLATION OF FIELDBUSES - INSTALLATION PROFILES FOR CPF 2 |
I.S. EN 61076-3-114:2009 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-114: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR FREQUENCIES UP TO 600 MHZ FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE - VARIANT 11 RELATED TO IEC 61076-3-106 - BAYONET COUPLING TYPE |
EN 61784-5-15:2012/A1:2015 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 5-15: INSTALLATION OF FIELDBUSES - INSTALLATION PROFILES FOR CPF 15 (IEC 61784-5-15:2010/A1:2015) |
EN 60512-26-100:2008/A1:2011 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 26-100: MEASUREMENT SETUP, TEST AND REFERENCE ARRANGEMENTS AND MEASUREMENTS FOR CONNECTORS ACCORDING TO IEC 60603-7 - TESTS 26A TO 26G |
IEC 60603-7-82:2016 | Connectors for electronic equipment - Part 7-82: Detail specification for 8-way, 12 contacts, shielded, free and fixed connectors, for data transmission with frequencies up to 2 000 MHz |
IEC 61076-3-115:2009 | Connectors for electronic equipment - Product requirements - Part 3-115: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface - Variant 12 related to IEC 61076-3-106 - Push-pull type |
EN 61784-5-12:2012/A1:2015 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 5-12: INSTALLATION OF FIELDBUSES - INSTALLATION PROFILES FOR CPF 12 (IEC 61784-5-12:2010/A1:2015) |
EN 61076-3-115:2010 | Connectors for electronic equipment - Product requirements - Part 3-115: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface - Variant 12 related to IEC 61076-3-106 - Push-pull type |
EN 61784-5-2:2013 | Industrial communication networks - Profiles - Part 5-2: Installation of fieldbuses - Installation profiles for CPF 2 |
EN 60603-7-82 : 2016 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-82: DETAIL SPECIFICATION FOR 8-WAY, 12 CONTACTS, SHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSION WITH FREQUENCIES UP TO 2000 MHZ (IEC 60603-7-82:2016) |
EN 50599:2014 | Generic cabling systems - Specification for the testing of balanced communication cabling in accordance with EN 50173-4 - Screened straight patch cords and straight work area cords for class D applications - Detail specification |
EN 61935-2-20:2009 | Testing of balanced communication cabling in accordance with series EN 50173 - Part 2-20: Patch cords and work area cords - Blank detail specification for class D applications |
EN 61162-450:2011/A1:2016 | MARITIME NAVIGATION AND RADIOCOMMUNICATION EQUIPMENT AND SYSTEMS - DIGITAL INTERFACES - PART 450: MULTIPLE TALKERS AND MULTIPLE LISTENERS - ETHERNET INTERCONNECTION |
CSA ISO/IEC 24740 : 2008 | INFORMATION TECHNOLOGY - RESPONSIVE LINK (RL) |
CSA ISO/IEC 24740 : 2008 : R2013 | INFORMATION TECHNOLOGY - RESPONSIVE LINK (RL) |
IEC 60603-7-1:2011 | Connectors for electronic equipment - Part 7-1: Detail specification for 8-way, shielded, free and fixed connectors |
IEC 62153-4-12:2009 | Metallic communication cable test methods - Part 4-12: Electromagnetic compatibility (EMC) - Coupling attenuation or screening attenuation of connecting hardware - Absorbing clamp method |
ISO/IEC 11801:2002 | Information technology Generic cabling for customer premises |
IEC 60512-27-100:2011 | Connectors for electronic equipment - Tests and measurements - Part 27-100: Signal integrity tests up to 500 MHz on 60603-7 series connectors - Tests 27a to 27g |
IEC 60512-26-100:2008+AMD1:2011 CSV | Connectors for electronic equipment - Tests and measurements - Part 26-100: Measurement setup, test and reference arrangements and measurements for connectors according to IEC 60603-7 - Tests 26a to 26g |
IEC 60603-7:2008+AMD1:2011 CSV | Connectors for electronic equipment - Part 7: Detail specification for 8-way, unshielded, free and fixed connectors |
IEC 60512-1-100:2012 | Connectors for electronic equipment - Tests and measurements - Part 1-100: General - Applicable publications |
IEC 60512-2-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 2-1: Electrical continuity and contact resistance tests - Test 2a: Contact resistance - Millivolt level method |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.