IEC 60332-3-10:2000+AMD1:2008 CSV
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
12-09-2022
English - French, Spanish, Castilian
11-02-2009
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Definitions
4 Test environment
5 Test apparatus
5.1 Test chamber
5.2 Air supply
5.3 Ladder types
5.4 Effluent cleaning attachment
6 Ignition source
6.1 Type
6.2 Positioning
Annex A (informative) Details of recommended burner
Annex B (informative) Flowmeter calibration correction
factors
IEC 60332-3-10:2000+A1:2008 specifies method of test for the assessment of vertical flame spread of vertically-mounted bunched wires or cables, electrical or optical, under defined conditions. Gives details of the apparatus and its arrangement and calibration. Has the status of a group safety publication in accordance with IEC Guide 104. This consolidated version consists of the first edition (2000) and its amendment 1 (2008). Therefore, no need to order amendment in addition to this publication.
Committee |
TC 20
|
DevelopmentNote |
Supersedes IEC 60332-3 (03/2001) Stability Date: 2017. (09/2017)
|
DocumentType |
Standard
|
Pages |
41
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
PN EN 60332-3-10 : 2009 | Identical |
NEN EN 50266-1 : 2001 | Identical |
UNE-EN 60332-3-10:2009 | Identical |
VDE 0482-332-3-10 : 2010 | Identical |
EN 60332-3-10:2009 | Identical |
I.S. EN 60332-3-10:2009 | Identical |
NEN EN IEC 60332-3-10 : 2009 | Identical |
NF EN 60332-3-10 : 2010 | Identical |
AS/NZS IEC 60332.3.10:2017 | Identical |
BS EN 60332-3-10:2009 | Identical |
DIN EN 60332-3-10 : 2010 | Identical |
BS EN 60076-11:2004 | Power transformers Dry-type transformers |
09/30194263 DC : 0 | BS EN 61439-6 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 6: BUSBAR TRUNKING SYSTEMS (BUSWAYS) |
NF EN 60332-3-22 : 2010 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 3-22: TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY-MOUNTED BUNCHED WIRES OR CABLES - CATEGORY A |
CEI EN 60332-3-25 : 2010 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 3-25: TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY-MOUNTED BUNCHED WIRES OR CABLES - CATEGORY D |
I.S. EN 50399:2011 | COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - HEAT RELEASE AND SMOKE PRODUCTION MEASUREMENT ON CABLES DURING FLAME SPREAD TEST - TEST APPARATUS, PROCEDURES, RESULTS |
GOST R IEC 60332-3-24 : 2005 AMD 1 2011 | TESTS ON ELECTRIC AND OPTICAL CABLES UNDER FIRE CONDITIONS - PART 3-24: FLAME SPREAD OF VERTICALLY-MOUNTED BUNCHED WIRES OR CABLES - CATEGORY C |
IEC 60332-3-21:2000 | Tests on electric cables under fire conditions - Part 3-21: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A F/R |
NF EN 60076-11 : 2004 | POWER TRANSFORMERS - PART 11: DRY-TYPE TRANSFORMERS |
IEEE DRAFT 1202 : 0 | FLAME-PROPAGATION TESTING OF WIRE AND CABLE |
I.S. EN 60076-11:2004 | POWER TRANSFORMERS - PART 11: DRY-TYPE TRANSFORMERS |
IEC 61156-1:2007+AMD1:2009 CSV | Multicore and symmetrical pair/quad cables for digital communications - Part 1: Generic specification |
IEEE 525-2007 | IEEE Guide for the Design and Installation of Cable Systems in Substations |
GOST R IEC 60332-3-22 : 2005 AMD 1 2011 | TESTS ON ELECTRIC AND OPTICAL CABLES UNDER FIRE CONDITIONS - PART 3-22: FLAME SPREAD OF VERTICALLY-MOUNTED BUNCHED WIRES OR CABLES - CATEGORY A |
ISO/TR 5660-3:2003 | Reaction-to-fire tests Heat release, smoke production and mass loss rate Part 3: Guidance on measurement |
EN 60695-9-2:2014 | Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods |
03/318326 DC : DRAFT NOV 2003 | |
UNE-EN 60695-8-2:2017 | Fire hazard testing - Part 8-2: Heat release - Summary and relevance of test methods |
DIN EN 12601:2011-07 | RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY |
EN 60332-3-21:2009 | Tests on electric and optical fibre cables under fire conditions - Part 3-21: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A F/R |
HD 620 : 2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV |
EN 60332-3-22:2009 | Tests on electric and optical fibre cables under fire conditions - Part 3-22: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A |
EN 60076-11:2004 | Power transformers - Part 11: Dry-type transformers |
EN 12601:2010 | Reciprocating internal combustion engine driven generating sets - Safety |
EN 60695-8-2:2017 | Fire hazard testing - Part 8-2: Heat release - Summary and relevance of test methods |
PD ISO/TS 5660-3:2012 | Reaction-to-fire tests. Heat release, smoke production and mass loss rate Guidance on measurement |
UNE-EN 61439-6:2013 | Low-voltage switchgear and controlgear assemblies - Part 6: Busbar trunking systems (busways) |
GOST R IEC 60332-3-23 : 2005 AMD 1 2011 | TESTS ON ELECTRIC AND OPTICAL CABLES UNDER FIRE CONDITIONS - PART 3-23: FLAME SPREAD OF VERTICALLY-MOUNTED BUNCHED WIRES OR CABLES - CATEGORY B |
03/309751 DC : DRAFT JUNE 2003 | IEC 60695-9-1 - FIRE HAZARD TESTING - PART 9: SURFACE SPREAD OF FLAME - GENERAL GUIDANCE |
CEI EN 60332-3-24 : 2010 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 3-24: TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY-MOUNTED BUNCHED WIRES OR CABLES - CATEGORY C |
BS EN 60332-3-25:2009 | Tests on electric and optical fibre cables under fire conditions Test for vertical flame spread of vertically-mounted bunched wires or cables. Category D |
PREN 12601 : DRAFT 2010 | RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY |
UNE-EN 50399:2012 | Common test methods for cables under fire conditions - Heat release and smoke production measurement on cables during flame spread test - Test apparatus, procedures, results |
I.S. EN 60695-9-2:2014 | FIRE HAZARD TESTING - PART 9-2: SURFACE SPREAD OF FLAME - SUMMARY AND RELEVANCE OF TEST METHODS |
CEI EN 60695-6-2 : 2013 | FIRE HAZARD TESTING - PART 6-2: SMOKE OBSCURATION - SUMMARY AND RELEVANCE OF TEST METHODS |
BS EN 12601:2010 | Reciprocating internal combustion engine driven generating sets. Safety |
BS EN 60332-3-23:2009 | Tests on electric and optical fibre cables under fire conditions Test for vertical flame spread of vertically-mounted bunched wires or cables. Category B |
I.S. EN 60695-8-2:2017 | FIRE HAZARD TESTING - PART 8-2: HEAT RELEASE - SUMMARY AND RELEVANCE OF TEST METHODS |
10/30211242 DC : 0 | BS EN 12601 - RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY |
05/30131385 DC : DRAFT MAR 2005 | IEC 61156-1 ED 3 - MULTICORE AND SYMMETRICAL PAIR/QUAD CABLES FOR DIGITAL COMMUNICATIONS - PART 1: GENERIC SPECIFICATION |
IEC TR 60695-8-2:2008 | Fire hazard testing - Part 8-2: Heat release - Summary and relevance of test methods |
I.S. EN 60332-3-25:2009 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 3-25: TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY-MOUNTED BUNCHED WIRES OR CABLES - CATEGORY D |
GOST R IEC 60332-3-25 : 2005 AMD 1 2011 | TESTS ON ELECTRIC AND OPTICAL CABLES UNDER FIRE CONDITIONS - PART 3-25: FLAME SPREAD OF VERTICALLY-MOUNTED BUNCHED WIRES OR CABLES - CATEGORY D |
BS EN 50399:2011 | Common test methods for cables under fire conditions. Heat release and smoke production measurement on cables during flame spread test. Test apparatus, procedures, results |
ISO/TS 5660-3:2012 | Reaction-to-fire tests — Heat release, smoke production and mass loss rate — Part 3: Guidance on measurement |
IEC 60332-3-24:2000+AMD1:2008 CSV | Tests on electric and optical fibre cables under fire conditions - Part 3-24: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category C |
UNE-EN 60695-9-2:2014 | Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods |
IEC TS 60695-9-2:2005 | Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods |
IEC 60695-6-2:2011 | Fire hazard testing - Part 6-2: Smoke obscuration - Summary and relevance of test methods |
IEC 60695-9-2:2014 | Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods |
ISO/TR 10093:2017 | Plastics Fire tests Standard ignition sources |
IEC 60332-3-25:2000+AMD1:2008 CSV | Tests on electric and optical fibre cables under fire conditions - Part 3-25: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category D |
EN 60332-3-24:2009 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 3-24: TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY-MOUNTED BUNCHED WIRES OR CABLES - CATEGORY C |
UNI EN 12601 : 2011 | RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY |
NF EN 60332-3-25 : 2010 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 3-25: TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY-MOUNTED BUNCHED WIRES OR CABLES - CATEGORY D |
NF EN 60332-3-24 : 2010 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 3-24: TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY-MOUNTED BUNCHED WIRES OR CABLES - CATEGORY C |
I.S. EN 12601:2010 | RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY |
09/30198671 DC : DRAFT JAN 2009 | BS EN 60332-3-25 - TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 3-25: TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY-MOUNTED BUNCHED WIRES OR CABLES - CATEGORY D |
BS EN 60332-3-22:2009 | Tests on electric and optical fibre cables under fire conditions Test for vertical flame spread of vertically-mounted bunched wires or cables. Category A |
CEI 20-22/0 : 2006 | TEST ON ELECTRIC CABLES UNDER FIRE CONDITIONS - PART 0: TEST OF NO PROPAGATION OF FIRE - GENERAL PRINCIPLES |
NF EN 60332-3-23 : 2010 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 3-23: TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY-MOUNTED BUNCHED WIRES OR CABLES - CATEGORY B |
BS EN 60332-3-24:2009 | Tests on electric and optical fibre cables under fire conditions Test for vertical flame spread of vertically-mounted bunched wires or cables. Category C |
IEEE 1202-2006 | IEEE Standard for Flame-Propagation Testing of Wire & Cable |
I.S. EN 61439-6:2012 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 6: BUSBAR TRUNKING SYSTEMS (BUSWAYS) (IEC 61439-6:2012 (EQV)) |
UNE-EN 60695-6-2:2012 | Fire hazard testing - Part 6-2: Smoke obscuration - Summary and relevance of test methods |
CEI EN 60332-3-23 : 2010 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 3-23: TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY-MOUNTED BUNCHED WIRES OR CABLES - CATEGORY B |
GOST R IEC 60332-3-21 : 2005 | TESTS ON ELECTRIC AND OPTICAL CABLES UNDER FIRE CONDITIONS - PART 3-21: FLAME SPREAD OF VERTICALLY-MOUNTED BUNCHED WIRES OR CABLES - CATEGORY A F/R |
I.S. EN 60695-6-2:2011 | FIRE HAZARD TESTING - PART 6-2: SMOKE OBSCURATION - SUMMARY AND RELEVANCE OF TEST METHODS (IEC 60695-6-2:2011) |
I.S. HD 620:2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV |
DD IEC TS 60695-9-2 : DRAFT 2005 | FIRE HAZARD TESTING - PART 9-2: SURFACE SPREAD OF FLAME - SUMMARY AND RELEVANCE OF TEST METHODS |
IEC 61439-6:2012 | Low-voltage switchgear and controlgear assemblies - Part 6: Busbar trunking systems (busways) |
BS EN 60695-9-2:2014 | Fire hazard testing Surface spread of flame. Summary and relevance of test methods |
BS EN 60695-8-2:2017 | Fire hazard testing Heat release. Summary and relevance of test methods |
IEC 60332-3-23:2000+AMD1:2008 CSV | Tests on electric and optical fibre cables under fire conditions - Part 3-23: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category B |
IEC 60332-3-22:2000+AMD1:2008 CSV | Tests on electric and optical fibre cables under fire conditions - Part 3-22: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A |
EN 60332-3-23:2009 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 3-23: TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY-MOUNTED BUNCHED WIRES OR CABLES - CATEGORY B |
CEI EN 60332-3-21 : 2010 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 3-21: TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY-MOUNTED BUNCHED WIRES OR CABLES - CATEGORY A F/R |
NF EN 60332-3-21 : 2010 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 3-21: TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY-MOUNTED BUNCHED WIRES OR CABLES - PROCEDURES - CATEGORY A F/R |
CEI EN 60332-3-22 : 2010 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 3-22: TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY-MOUNTED BUNCHED WIRES OR CABLES - CATEGORY A |
CEI EN 60076-11 : 2006 | POWER TRANSFORMERS - PART 11: DRY-TYPE TRANSFORMERS |
BS EN 61439-6:2012 | Low-voltage switchgear and controlgear assemblies Busbar trunking systems (busways) |
ABS 0063 : 2018 COR 2018 | RULES FOR BUILDING AND CLASSING FACILITIES ON OFFSHORE INSTALLATIONS |
CEI EN 61439-6 : 2013 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 6: BUSBAR TRUNKING SYSTEMS (BUSWAYS) |
15/30329860 DC : 0 | BS EN 50399:2011/A1 - COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - HEAT RELEASE AND SMOKE PRODUCTION MEASUREMENT ON CABLES DURING FLAME SPREAD TEST - TEST APPARATUS, PROCEDURES, RESULTS |
BS EN 60332-3-21:2009 | Tests on electric and optical fibre cables under fire conditions Test for vertical flame spread of vertically-mounted bunched wires or cables. Category A F/R |
16/30349321 DC : 0 | BS EN 60076-11 ED 2.0 - POWER TRANSFORMERS - PART 11: DRY-TYPE TRANSFORMERS |
I.S. EN 60332-3-21:2009 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 3-21: TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY-MOUNTED BUNCHED WIRES OR CABLES - CATEGORY A F/R |
I.S. EN 60332-3-23:2009 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 3-23: TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY-MOUNTED BUNCHED WIRES OR CABLES - CATEGORY B |
I.S. EN 60332-3-24:2009 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 3-24: TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY-MOUNTED BUNCHED WIRES OR CABLES - CATEGORY C |
I.S. EN 60332-3-22:2009 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 3-22: TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY-MOUNTED BUNCHED WIRES OR CABLES - CATEGORY A |
IEEE 1717-2012 | IEEE Standard for Testing Circuit Integrity Cables Using a Hydrocarbon Pool Fire Test Protocol |
13/30277762 DC : 0 | BS EN 60695-8-2 IEC 60695-8-2 ED 1.0 - FIRE HAZARD TESTING - PART 8-2: HEAT RELEASE - SUMMARY AND RELEVANCE OF TEST METHODS |
BS EN 60695-6-2:2011 | Fire hazard testing Smoke obscuration. Summary and relevance of test methods |
PD IEC/TR 60695-8-2:2008 | Fire hazard testing Heat release. Summary and relevance of test methods |
04/30111706 DC : DRAFT MAR 2004 | IEC 60695-9-2 ED.2 - FIRE HAZARD TESTING - PART 9-2: SURFACE SPREAD OF FLAME - SUMMARY AND RELEVANCE OF TEST METHODS |
UNE-EN 12601:2011 | Reciprocating internal combustion engine driven generating sets - Safety |
EN 60332-3-25:2009 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 3-25: TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY-MOUNTED BUNCHED WIRES OR CABLES - CATEGORY D |
EN 61439-6 : 2012 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 6: BUSBAR TRUNKING SYSTEMS (BUSWAYS) (IEC 61439-6:2012) |
EN 50399 : 2011 AMD 1 2016 | COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - HEAT RELEASE AND SMOKE PRODUCTION MEASUREMENT ON CABLES DURING FLAME SPREAD TEST - TEST APPARATUS, PROCEDURES, RESULTS |
EN 60695-6-2:2011 | FIRE HAZARD TESTING - PART 6-2: SMOKE OBSCURATION - SUMMARY AND RELEVANCE OF TEST METHODS (IEC 60695-6-2:2011) |
CEI EN 50399:2022-12 | Common test methods for cables under fire conditions - Heat release and smoke production measurement on cables during flame spread test - Test apparatus, procedures, results |
AS/NZS IEC 60332.1.2:2017 | Tests on electric and optical fibre cables under fire conditions Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame |
IEC 60695-4:2012 | Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products |
IEC GUIDE 104:2010 | The preparation of safety publications and the use of basic safety publications and group safety publications |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.