IEC 60318-4:2010
Current
The latest, up-to-date edition.
Electroacoustics - Simulators of human head and ear - Part 4: Occluded-ear simulator for the measurement of earphones coupled to the ear by means of ear inserts
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French, Spanish, Castilian
21-01-2010
IEC 60318-4:2010 describes an occluded-ear simulator intended for the measurement of insert earphones in the frequency range from 100 Hz to 10 000 Hz. It is suitable for air conduction hearing aids and earphones, coupled to the ear by means of ear inserts e.g. ear moulds or similar devices. The occluded-ear simulator is also suitable as the basis for an extension intended to simulate the complete ear canal and the outer ear (for instance in head simulators). The occluded-ear simulator simulates the acoustic transfer impedance for the occluded normal adult human ear. However, it does not simulate the leakage between an earmould and a human ear canal; therefore, the results obtained with the occluded-ear simulator may deviate from the performance of an insert earphone on a real ear, especially at low frequencies. Moreover, large performance variations among individual ears will occur which should be considered when using the ear simulator. Above 10 kHz the device does not simulate a human ear, but can be used as an acoustic coupler at additional frequencies up to 16 kHz. Below 100 Hz, the device has not been verified to simulate a human ear, but can be used as an acoustic coupler at additional frequencies down to 20 Hz. IEC 60318-4:2010 cancels and replaces IEC 60711, published in 1981 and constitutes a technical revision. The main changes with respect to the previous edition are listed below:
- extension of the usable frequency range to 100 Hz - 16 000 Hz;
- addition of values of maximum permitted expanded uncertainties to all tolerances.
DevelopmentNote |
Supersedes IEC 60711. (01/2010) Stability Date: 2018. (09/2017)
|
DocumentType |
Standard
|
Pages |
38
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NEN EN IEC 60318-4 : 2010 | Identical |
I.S. EN 60318-4:2010 | Identical |
PN EN 60318-4 : 2011 | Identical |
UNE-EN 60318-4:2011 | Identical |
BS EN 60318-4:2010 | Identical |
CEI EN 60318-4 : 2011 | Identical |
EN 60318-4:2010 | Identical |
DIN EN 60318-4:2010-12 | Identical |
NF EN 60318-4 : 2011 | Identical |
08/30189820 DC : DRAFT SEP 2008 | BS EN ISO 8253-1 - ACOUSTICS - AUDIOMETRIC TEST METHODS - PART 1: BASIC PURE-TONE AIR AND BONE CONDUCTION THRESHOLD AUDIOMETRY |
PD IEC/TS 62886:2016 | Electroacoustics. Hearing aids. Method for measuring electroacoustic performance up to 16 kHz |
UNE-EN 60645-6:2010 | Electroacoustics - Audiometric equipment -- Part 6: Instruments for the measurement of otoacoustic emissions |
BS EN ISO 389-9:2009 | Acoustics. Reference zero for the calibration of audiometric equipment Preferred test conditions for the determination of reference hearing threshold levels |
09/30206924 DC : 0 | BS EN 60118-15 ED.1 - ELECTROACOUSTICS - PART 15: HEARING AIDS - METHODS FOR CHARACTERISING SIGNAL PROCESSING IN HEARING AIDS |
08/30177361 DC : DRAFT JAN 2008 | BS IEC 60118-13 - ELECTRO ACOUSTICS - HEARING AIDS - PART 13: ELECTROMAGNETIC COMPATIBILITY (EMC) |
BS EN 60118-0:2015 | Electroacoustics. Hearing aids Measurement of the performance characteristics of hearing aids |
BS EN ISO 8253-1:2010 | Acoustics. Audiometric test methods Pure-tone air and bone conduction audiometry |
EN 60118-15:2012 | Electroacoustics - Hearing aids - Part 15: Methods for characterising signal processing in hearing aids with a speech-like signal |
EN 61669:2016 | Electroacoustics - Measurement of real-ear acoustical performance characteristics of hearing aids |
BS EN 60645-6:2010 | Electroacoustics. Audiometric equipment Instruments for the measurement of otoacoustic emissions |
10/30240267 DC : 0 | BS EN 60601-2-66 ED.1 - ELECTROACOUSTICS - PART 2-66: HEARING INSTRUMENTS AND HEARING SYSTEMS - GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE |
I.S. EN 60118-15:2012 | ELECTROACOUSTICS - HEARING AIDS - PART 15: METHODS FOR CHARACTERISING SIGNAL PROCESSING IN HEARING AIDS WITH A SPEECH-LIKE SIGNAL (IEC 60118-15:2012 (EQV)) |
14/30313972 DC : 0 | BS EN 60645-1 ED.4.0 - ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AND SPEECH AUDIOMETRY |
07/30173580 DC : 0 | BS EN 60645-6 - ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 6: INSTRUMENTS FOR THE MEASUREMENT OF OTOACOUSTIC EMISSIONS |
IEC 61669:2015 | Electroacoustics - Measurement of real-ear acoustical performance characteristics of hearing aids |
CEI EN 60118-13 : 2012 | ELECTROACOUSTICS - HEARING AIDS - PART 13: ELECTROMAGNETIC COMPATIBILITY (EMC) |
IEC TS 62886:2016 | Electroacoustics - Hearing aids - Method for measuring electroacoustic performance up to 16 kHz |
I.S. EN 60645-6:2010 | ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 6: INSTRUMENTS FOR THE MEASUREMENT OF OTOACOUSTIC EMISSIONS |
UNI EN ISO 389-9 : 2009 | ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - PART 9: PREFERRED TEST CONDITIONS FOR THE DETERMINATION OF REFERENCE HEARING THRESHOLD LEVELS |
UNI EN 71-1 : 2015 | SAFETY OF TOYS - PART 1: MECHANICAL AND PHYSICAL PROPERTIES |
IEC 60645-1:2017 | Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry |
EN 60118-13:2011 | Electroacoustics - Hearing aids - Part 13: Electromagnetic compatibility (EMC) |
ISO 389-6:2007 | Acoustics Reference zero for the calibration of audiometric equipment Part 6: Reference threshold of hearing for test signals of short duration |
I.S. EN ISO 8253-1:2010 | ACOUSTICS - AUDIOMETRIC TEST METHODS - PART 1: PURE-TONE AIR AND BONE CONDUCTION AUDIOMETRY |
DIN EN ISO 389-9:2009-12 | Acoustics - Reference zero for the calibration of audiometric equipment - Part 9: Preferred test conditions for the determination of reference hearing threshold levels (ISO 389-9:2009) |
BS EN 60118-15:2012 | Electroacoustics. Hearing aids Methods for characterising signal processing in hearing aids with a speech-like signal |
BS EN 50332-1:2013 | Sound system equipment: Headphones and earphones associated with personal music players. Maximum sound pressure level measurement methodology General method for \'one package equipment\' |
ANSI S3.6 : 2010 | SPECIFICATION FOR AUDIOMETERS |
13/30282677 DC : 0 | BS EN 61669 ED.2 - ELECTROACOUSTICS - MEASUREMENT OF REAL-EAR ACOUSTICAL PERFORMANCE CHARACTERISTICS OF HEARING AIDS |
13/30281662 DC : 0 | BS EN 50332-1 - SOUND SYSTEM EQUIPMENT: HEADPHONES AND EARPHONES ASSOCIATED WITH PORTABLE AUDIO EQUIPMENT - MAXIMUM SOUND PRESSURE LEVEL MEASUREMENT METHODOLOGY AND LIMIT CONSIDERATIONS - PART 1: GENERAL METHOD FOR "ONE PACKAGE EQUIPMENT" |
15/30328565 DC : 0 | BS EN 60645-1 ED4.0 - ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AND SPEECH AUDIOMETRY |
PREN 50332-1 : DRAFT 2013 | SOUND SYSTEM EQUIPMENT: HEADPHONES AND EARPHONES ASSOCIATED WITH PORTABLE AUDIO EQUIPMENT - MAXIMUM SOUND PRESSURE LEVEL MEASUREMENT METHODOLOGY AND LIMIT CONSIDERATIONS - PART 1: GENERAL METHOD FOR "ONE PACKAGE EQUIPMENT" |
07/30173584 DC : 0 | BS EN 60645-7 - ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 7: INSTRUMENTS FOR THE MEASUREMENT OF AUDITORY EVOKED POTENTIALS |
I.S. EN 50332-1:2013 | SOUND SYSTEM EQUIPMENT: HEADPHONES AND EARPHONES ASSOCIATED WITH PERSONAL MUSIC PLAYERS - MAXIMUM SOUND PRESSURE LEVEL MEASUREMENT METHODOLOGY - PART 1: GENERAL METHOD FOR ONE PACKAGE EQUIPMENT |
I.S. EN 60645-1:2017 | ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AND SPEECH AUDIOMETRY |
IEEE/ANSI C63.19-2011 REDLINE | American National Standard Methods of Measurement of Compatibility between Wireless Communications Devices and Hearing Aids |
CSA Z107.56 : 2013 | MEASUREMENT OF NOISE EXPOSURE |
UNE-EN 60118-13:2012 | Electroacoustics - Hearing aids - Part 13: Electromagnetic compatibility (EMC) |
DIN EN 71-1:2015-02 | SAFETY OF TOYS - PART 1: MECHANICAL AND PHYSICAL PROPERTIES |
IEC TS 60318-7:2017 | Electroacoustics - Simulators of human head and ear - Part 7: Head and torso simulator for the measurement of air-conduction hearing aids |
I.S. EN 60118-13:2011 | ELECTROACOUSTICS - HEARING AIDS - PART 13: ELECTROMAGNETIC COMPATIBILITY (EMC) |
IEC 60645-6:2009 | Electroacoustics - Audiometric equipment - Part 6: Instruments for the measurement of otoacoustic emissions |
UNE-EN ISO 8253-1:2011 | Acoustics - Audiometric test methods - Part 1: Pure-tone air and bone conduction audiometry (ISO 8253-1:2010) |
EN ISO 8253-1:2010 | Acoustics - Audiometric test methods - Part 1: Pure-tone air and bone conduction audiometry (ISO 8253-1:2010) |
UNI EN ISO 8253-1 : 2010 | ACOUSTICS - AUDIOMETRIC TEST METHODS - PART 1: PURE-TONE AIR AND BONE CONDUCTION AUDIOMETRY |
08/30176438 DC : DRAFT JAN 2008 | BS EN 60645-1 - ELECTRO ACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: PURE-TONE AUDIOMETERS |
12/30264287 DC : 0 | BS EN 60118-13 ED.4 - ELECTROACOUSTICS - HEARING AIDS - PART 13: ELECTROMAGNETIC COMPATABILITY (EMC) (REVISION OF IEC 60118-13: 2011) |
ANSI/ASA S3.36:2012(R2018) | SPECIFICATION FOR A MANIKIN FOR SIMULATED IN-SITU AIRBORNE ACOUSTIC MEASUREMENTS |
NF EN 60645-6 : 2010 | ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 6: INSTRUMENTS FOR THE MEASUREMENT OF OTOACOUSTIC EMISSIONS |
BS EN 60645-1:2017 | Electroacoustics. Audiometric equipment Equipment for pure-tone and speech audiometry |
07/30166205 DC : 0 | BS ISO 389-9 - ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - PART 9: PREFERRED TEST CONDITIONS FOR THE DETERMINATION OF REFERENCE HEARING THRESHOLD LEVELS |
NF EN 60118-13 : 2012 | ELECTROACOUSTICS - HEARING AIDS - PART 13: ELECTROMAGNETIC COMPATIBILITY (EMC) |
CEI EN 60118-15 : 2014 | ELECTROACOUSTICS - HEARING AIDS - PART 15: METHODS FOR CHARACTERISING SIGNAL PROCESSING IN HEARING AIDS WITH A SPEECH-LIKE SIGNAL |
BS EN 71-1 : 2014 | SAFETY OF TOYS - PART 1: MECHANICAL AND PHYSICAL PROPERTIES |
EN 71-1:2014 | Safety of toys - Part 1: Mechanical and physical properties |
I.S. EN ISO 389-9:2009 | ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - PART 9: PREFERRED TEST CONDITIONS FOR THE DETERMINATION OF REFERENCE HEARING THRESHOLD LEVELS |
16/30348450 DC : 0 | BS EN 13819-3 - HEARING PROTECTORS - TESTING - PART 3: SUPPLEMENTARY ACOUSTIC TEST METHOD |
ANSI S3.42-2 : 2012 | TESTING HEARING AIDS - PART 2: METHODS FOR CHARACTERIZING SIGNAL PROCESSING IN HEARING AIDS WITH A SPEECH-LIKE SIGNAL |
I.S. EN 71-1:2014 | SAFETY OF TOYS - PART 1: MECHANICAL AND PHYSICAL PROPERTIES |
UNE-EN 60645-1:2015 | Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone audiometry |
IEC 60645-1:2017 RLV | Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry |
ISO 389-9:2009 | Acoustics Reference zero for the calibration of audiometric equipment Part 9: Preferred test conditions for the determination of reference hearing threshold levels |
IEC 60118-0:2015 | Electroacoustics - Hearing aids - Part 0: Measurement of the performance characteristics of hearing aids |
UNE-EN 60118-0:2016 | Electroacoustics - Hearing aids - Part 0: Measurement of the performance characteristics of hearing aids |
BS EN ISO 389-6:2007 | Acoustics. Reference zero for the calibration of audiometric equipment Reference threshold of hearing for test signals of short duration |
ISO 8253-1:2010 | Acoustics Audiometric test methods Part 1: Pure-tone air and bone conduction audiometry |
IEC 60118-15:2012 | Electroacoustics - Hearing aids - Part 15: Methods for characterising signal processing in hearing aids with a speech-like signal |
EN ISO 389-9:2009 | Acoustics - Reference zero for the calibration of audiometric equipment - Part 9: Preferred test conditions for the determination of reference hearing threshold levels (ISO 389-9:2009) |
EN ISO 389-6:2007 | Acoustics - Reference zero for the calibration of audiometric equipment - Part 6: Reference threshold of hearing for test signals of short duration (ISO 389-6:2007) |
CSA Z107.56 : 2013:R2018 | MEASUREMENT OF NOISE EXPOSURE |
DD IEC/TS 60318-7:2011 | Electroacoustics. Simulators of human head and ear Head and torso simulator for the measurement of hearing aids |
10/30217127 DC : 0 | BS EN 60645-2 ED 2 - AUDIOMETRIC EQUIPMENT - PART 2: EQUIPMENT FOR SPEECH AUDIOMETRY |
UNE-EN 71-1:2015 | Safety of toys - Part 1: Mechanical and physical properties |
BS EN 60118-13:2011 | Electroacoustics. Hearing aids Electromagnetic compatibility (EMC) |
UNE-EN 60118-15:2012 | Electroacoustics - Hearing aids - Part 15: Methods for characterising signal processing in hearing aids with a speech-like signal |
I.S. EN 61669:2016 | ELECTROACOUSTICS - MEASUREMENT OF REAL-EAR ACOUSTICAL PERFORMANCE CHARACTERISTICS OF HEARING AIDS |
ANSI S3.25 : 2009 | OCCLUDED EAR SIMULATOR |
ANSI/ASA S3.25 : 2009(R2014) | OCCLUDED EAR SIMULATOR |
ANSI S3.36 : 2012 | SPECIFICATION FOR A MANIKIN FOR SIMULATED IN-SITU AIRBORNE ACOUSTIC MEASUREMENTS |
DIN EN ISO 389-6:2007-10 | Acoustics - Reference zero for the calibration of audiometric equipment - Part 6: Reference threshold of hearing for test signals of short duration (ISO 389-6:2007) |
EN 50332-1:2013 | Sound system equipment: Headphones and earphones associated with personal music players - Maximum sound pressure level measurement methodology - Part 1: General method for "one package equipment" |
EN 60118-0:2015 | Electroacoustics - Hearing aids - Part 0: Measurement of the performance characteristics of hearing aids |
EN 60645-1:2017 | Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry |
EN 60645-6:2010 | Electroacoustics - Audiometric equipment - Part 6: Instruments for the measurement of otoacoustic emissions |
ANSI/ASA S3.7 : 2016 | METHOD FOR MEASUREMENT AND CALIBRATION OF EARPHONES |
IEC 61094-4:1995 | Measurement microphones - Part 4: Specifications for working standard microphones |
ISO 389-5:2006 | Acoustics Reference zero for the calibration of audiometric equipment Part 5: Reference equivalent threshold sound pressure levels for pure tones in the frequency range 8 kHz to 16 kHz |
ISO 389-6:2007 | Acoustics Reference zero for the calibration of audiometric equipment Part 6: Reference threshold of hearing for test signals of short duration |
ISO 389-2:1994 | Acoustics Reference zero for the calibration of audiometric equipment Part 2: Reference equivalent threshold sound pressure levels for pure tones and insert earphones |
AS/NZS ISO 8253.1:2019 | Acoustics - Audiometric test methods Pure-tone air and bone conduction audiometry |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.