• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

IEC 60318-3:2014

Current

Current

The latest, up-to-date edition.

Electroacoustics - Simulators of human head and ear - Part 3: Acoustic coupler for the calibration of supra-aural earphones used in audiometry

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English - French

Published date

11-12-2014

£71.17
Excluding VAT

IEC 60318-3:2014 specifies an acoustic coupler for the measurement of supra-aural audiometric earphones in the frequency range from 125 Hz to 8 000 Hz. The sound pressure developed by an earphone is not, in general, the same in the coupler as in a person's ear. However, the acoustic coupler can be used as an objective and reproducible means of measuring the output of supra-aural earphones. It can be used for specifying reference equivalent threshold sound pressure levels for the calibration of audiometers. This second edition cancels and replaces the first edition published in 1998 and constitutes a technical revision which includes the following significant technical changes with respect to the previous edition:
- adjustment of terms and wording to the other parts of IEC 60318;
- introduction of maximum permitted uncertainties;
- and revised requirements for static pressure equalization. Keywords: electroacoustics, deafness, hearing aids

DevelopmentNote
Supersedes IEC 60303 (03/2001) Stability date: 2017. (12/2014) Also numbered as ANSI S3.55-3. (06/2015)
DocumentType
Standard
Pages
24
PublisherName
International Electrotechnical Committee
Status
Current
Supersedes

08/30189820 DC : DRAFT SEP 2008 BS EN ISO 8253-1 - ACOUSTICS - AUDIOMETRIC TEST METHODS - PART 1: BASIC PURE-TONE AIR AND BONE CONDUCTION THRESHOLD AUDIOMETRY
BS EN ISO 389-9:2009 Acoustics. Reference zero for the calibration of audiometric equipment Preferred test conditions for the determination of reference hearing threshold levels
BS EN ISO 8253-3:2012 Acoustics. Audiometric test methods Speech audiometry
BS EN ISO 8253-1:2010 Acoustics. Audiometric test methods Pure-tone air and bone conduction audiometry
NF EN 60645-3 : 2007 ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 3: TEST SIGNALS OF SHORT DURATION
10/30213857 DC : 0 BS ISO 8253-3 - ACOUSTICS - AUDIOMETRIC TEST METHODS - PART 3: SPEECH AUDIOMETRY
14/30313972 DC : 0 BS EN 60645-1 ED.4.0 - ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AND SPEECH AUDIOMETRY
CEI EN 60645-1 : 2016 ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AUDIOMETRY
UNI EN ISO 389-9 : 2009 ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - PART 9: PREFERRED TEST CONDITIONS FOR THE DETERMINATION OF REFERENCE HEARING THRESHOLD LEVELS
IEC 60645-1:2017 Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry
DIN EN ISO 8253-3:2012-08 Acoustics - Audiometric test methods - Part 3: Speech audiometry (ISO 8253-3:2012)
I.S. EN ISO 8253-3:2012 ACOUSTICS - AUDIOMETRIC TEST METHODS - PART 3: SPEECH AUDIOMETRY (ISO 8253-3:2012)
I.S. EN ISO 8253-1:2010 ACOUSTICS - AUDIOMETRIC TEST METHODS - PART 1: PURE-TONE AIR AND BONE CONDUCTION AUDIOMETRY
EN 60645-3:2007 Electroacoustics - Audiometric equipment - Part 3: Test signals of short duration
DIN EN ISO 389-9:2009-12 Acoustics - Reference zero for the calibration of audiometric equipment - Part 9: Preferred test conditions for the determination of reference hearing threshold levels (ISO 389-9:2009)
BS EN 60645-1:2017 Electroacoustics. Audiometric equipment Equipment for pure-tone and speech audiometry
17/30333265 DC : 0 BS EN ISO 389-1 - ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - PART 1: REFERENCE EQUIVALENT THRESHOLD SOUND PRESSURE LEVELS FOR PURE TONES AND SUPRA-AURAL EARPHONES
ANSI S3.6 : 2010 SPECIFICATION FOR AUDIOMETERS
BS EN 60268-7:2011 Sound system equipment Headphones and earphones
15/30328565 DC : 0 BS EN 60645-1 ED4.0 - ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AND SPEECH AUDIOMETRY
07/30173584 DC : 0 BS EN 60645-7 - ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 7: INSTRUMENTS FOR THE MEASUREMENT OF AUDITORY EVOKED POTENTIALS
I.S. EN 60645-1:2017 ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AND SPEECH AUDIOMETRY
UNE-EN ISO 8253-1:2011 Acoustics - Audiometric test methods - Part 1: Pure-tone air and bone conduction audiometry (ISO 8253-1:2010)
EN 60268-7:2011 Sound system equipment - Part 7: Headphones and earphones
EN ISO 389-1:2000 Acoustics - Reference zero for the calibration of audiometric equipment - Part 1: Reference equivalent threshold sound pressure levels for pure tones and supra-aural earphones (ISO 389-1:1998)
EN ISO 8253-1:2010 Acoustics - Audiometric test methods - Part 1: Pure-tone air and bone conduction audiometry (ISO 8253-1:2010)
UNI EN ISO 8253-1 : 2010 ACOUSTICS - AUDIOMETRIC TEST METHODS - PART 1: PURE-TONE AIR AND BONE CONDUCTION AUDIOMETRY
CEI EN 60645-3 : 2008 ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 3: TEST SIGNALS OF SHORT DURATION
ANSI/ASA S3.20 : 2015 American National Standard Bioacoustical Terminology
CEI EN 60268-7 : 2012 SOUND SYSTEM EQUIPMENT - PART 7: HEADPHONES AND EARPHONES
PD 6545:2005 Intended use of human head and ear simulators-guide
08/30176438 DC : DRAFT JAN 2008 BS EN 60645-1 - ELECTRO ACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: PURE-TONE AUDIOMETERS
07/30166205 DC : 0 BS ISO 389-9 - ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - PART 9: PREFERRED TEST CONDITIONS FOR THE DETERMINATION OF REFERENCE HEARING THRESHOLD LEVELS
BS EN 60645-3:2007 Electroacoustics. Audiometric equipment Test signals of short duration
BS EN ISO 389-1:2000 Acoustics. Reference zero for the calibration of audiometric equipment Reference equivalent threshold sound pressure levels for pure tones and supra-aural earphones
I.S. EN ISO 389-1:2018 ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - PART 1: REFERENCE EQUIVALENT THRESHOLD SOUND PRESSURE LEVELS FOR PURE TONES AND SUPRA-AURAL EARPHONES (ISO 389-1:2017)
I.S. EN ISO 389-9:2009 ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - PART 9: PREFERRED TEST CONDITIONS FOR THE DETERMINATION OF REFERENCE HEARING THRESHOLD LEVELS
I.S. EN 60645-3:2007 ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 3: TEST SIGNALS OF SHORT DURATION
I.S. EN 60268-7:2011 SOUND SYSTEM EQUIPMENT - PART 7: HEADPHONES AND EARPHONES
UNE-EN 60645-1:2015 Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone audiometry
IEC 60645-1:2017 RLV Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry
ISO 389-9:2009 Acoustics Reference zero for the calibration of audiometric equipment Part 9: Preferred test conditions for the determination of reference hearing threshold levels
IEC 60268-7:2010 Sound system equipment - Part 7: Headphones and earphones
ISO 8253-1:2010 Acoustics Audiometric test methods Part 1: Pure-tone air and bone conduction audiometry
IEC 60645-3:2007 Electroacoustics - Audiometric equipment - Part 3: Test signals of short duration
UNE-EN 60268-7:2013 Sound system equipment -- Part 7: Headphones and earphones
ISO 8253-3:2012 Acoustics Audiometric test methods Part 3: Speech audiometry
EN ISO 389-9:2009 Acoustics - Reference zero for the calibration of audiometric equipment - Part 9: Preferred test conditions for the determination of reference hearing threshold levels (ISO 389-9:2009)
UNI EN ISO 8253-3 : 2012 ACOUSTICS - AUDIOMETRIC TEST METHODS - PART 3: SPEECH AUDIOMETRY
IEEE DRAFT C63.19 : 2005 METHODS OF MEASUREMENT OF COMPATIBILITY BETWEEN WIRELESS COMMUNICATIONS DEVICES AND HEARING AIDS
04/30117001 DC : DRAFT JUL 2004 IEC 60645-3. ED.2.0 - AUDIOMETERS - PART 3: AUDITORY TEST SIGNALS OF SHORT DURATION FOR AUDIOMETRIC AND NEURO-OTOLOGICAL PURPOSES
10/30217127 DC : 0 BS EN 60645-2 ED 2 - AUDIOMETRIC EQUIPMENT - PART 2: EQUIPMENT FOR SPEECH AUDIOMETRY
IEEE/ANSI C63.19-2011 REDLINE American National Standard Methods of Measurement of Compatibility between Wireless Communications Devices and Hearing Aids
ANSI/ASA S3.7 : 2016 METHOD FOR MEASUREMENT AND CALIBRATION OF EARPHONES
ISO 389-1:2017 Acoustics — Reference zero for the calibration of audiometric equipment — Part 1: Reference equivalent threshold sound pressure levels for pure tones and supra-aural earphones
EN ISO 8253-3:2012 Acoustics - Audiometric test methods - Part 3: Speech audiometry (ISO 8253-3:2012)
EN 60645-1:2017 Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry

ANSI/ASA S3.7 : 2016 METHOD FOR MEASUREMENT AND CALIBRATION OF EARPHONES
IEC 61094-4:1995 Measurement microphones - Part 4: Specifications for working standard microphones
IEC 61094-1:2000 Measurement microphones - Part 1: Specifications for laboratory standard microphones
AS/NZS ISO 389.1:2019 Acoustics - Reference zero for the calibration of audiometric equipment Reference equivalent threshold sound pressure levels for pure tones and supra-aural earphones
AS/NZS ISO 8253.3:2019 Acoustics - Audiometric test methods Speech audiometry
AS/NZS ISO 8253.1:2019 Acoustics - Audiometric test methods Pure-tone air and bone conduction audiometry
ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.