IEC 60317-27:2013
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
Specifications for particular types of winding wires - Part 27: Paper tape covered rectangular copper wire
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
12-09-2022
English - French, Spanish, Castilian
10-10-2013
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions, general notes and appearance
4 Dimensions
5 Electrical resistance
6 Elongation
7 Springiness
8 Flexibility and adherence
9 Heat shock
10 Cut-through
11 Resistance to abrasion
12 Resistance to solvents
13 Breakdown voltage
14 Continuity of insulation
15 Temperature index
16 Resistance to refrigerants
17 Solderability
18 Heat or solvent bonding
19 Dielectric dissipation factor
20 Resistance to hydrolysis and to transformer oil
21 Loss of mass
23 Pin hole test
30 Packaging
Annex A (informative) - Method of determination
of x % proof stress: Rpx
Bibliography
IEC 60317-27:2013 specifies the requirements of paper tape covered rectangular copper winding wires. This covering consists of two or more layers of paper tape, all in the same direction and is primarily intended for winding coils for oil immersed transformers. The range of nominal conductor dimensions covered by this standard is:
- width: min. 2,0 mm max. 16,0 mm;
- thickness: min. 0,80 mm max. 5,60 mm. The paper tapes covered by this standard are restricted to those specified in IEC 60554-1 having thicknesses in the range 25 μm to 125 μm inclusive. This fourth edition cancels and replaces the third edition published in 1998, Amendment 1:1999. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- new subclause containing general notes on winding wire, formerly a part of the scope;
- revision to references to IEC 60317-0-2:2013 to clarify that their application is normative;
- new 3.3, Appearance;
- modification to 4.4, Increase in dimensions due to paper tape covering;
- deletion of Clause 22, High temperature failure;
- new Clause 23, Pin hole test. Keywords: requirements of paper tape covered rectangular copper winding wires, winding coils for oil immersed transformers
This publication is to be read in conjunction with IEC 60317-0-2:2013.
Committee |
TC 55
|
DevelopmentNote |
Supersedes IEC 60182-3 (03/2001) To be read in conjunction with the IEC 60317-0-2. Stability date: 2018. (10/2013)
|
DocumentType |
Standard
|
Pages |
24
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
Supersedes |
Standards | Relationship |
OVE/ONORM EN 60317-27 : 2014 | Identical |
NF EN 60317-27 : 2014 | Identical |
NBN EN 60317-27 : 2014 | Identical |
NEN EN IEC 60317-27 : 2014 | Identical |
I.S. EN 60317-27:2014 | Identical |
PN EN 60317-27 : 2014 | Identical |
BS EN 60317-27:2014 | Identical |
UNE-EN 60317-27:2014 | Identical |
CEI EN 60317-27 : 2014 | Identical |
EN 60317-27:2014 | Identical |
DIN EN 60317-27:2014-09 | Identical |
SN EN 60317-27:2014 | Identical |
19/30386553 DC : 2019 | Identical |
UNE 21179-27:1993 | Identical |
CEI 55-2/27 : 4ED 1991 | Identical |
SN EN 60317-27 : 1998 AMD 1 2000 | Identical |
BS IEC 61858-2 : 2014 | ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED ELECTRICAL INSULATION SYSTEM (EIS) - PART 2: FORM-WOUND EIS |
EN 61858-2:2014 | Electrical insulation systems - Thermal evaluation of modifications to an established electrical insulation system (EIS) - Part 2: Form-wound EIS |
12/30273912 DC : 0 | BS EN 61858-2 - ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED EIS - PART-2: FORM-WOUND EIS |
I.S. EN 61858-2:2014 | ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED ELECTRICAL INSULATION SYSTEM (EIS) - PART 2: FORM-WOUND EIS |
IEC 60034-18-22:2000 | Rotating electrical machines - Part 18-22: Functional evaluation of insulation systems - Test procedures for wire-wound windings - Classification of changes and insulation component substitutions |
BS EN 61858-2:2014 | Electrical insulation systems. Thermal evaluation of modifications to an established electrical insulation system (EIS) Form-wound EIS |
IEC 61858-2:2014 | Electrical insulation systems - Thermal evaluation of modifications to an established electrical insulation system (EIS) - Part 2: Form-wound EIS |
ISO 6892-1:2016 | Metallic materials Tensile testing Part 1: Method of test at room temperature |
IEC 60317-0-2:2013 | Specifications for particular types of winding wires - Part 0-2: General requirements - Enamelled rectangular copper wire |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.