IEC 60229:2007
Current
The latest, up-to-date edition.
Electric cables - Tests on extruded oversheaths with a special protective function
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French, Spanish, Castilian
10-10-2007
FOREWORD
1 Scope
2 Normative references
3 Routine tests
3.1 D.C. voltage test
3.2 Spark test
4 Type tests
4.1 Abrasion test
4.1.1 Purpose
4.1.2 Test procedure
4.1.3 Inspection
4.1.4 Performance requirement
4.2 Corrosion spread (aluminium metallic screen only)
4.2.1 General
4.2.2 Test procedure
4.2.3 Inspection
4.2.4 Performance requirement
5 Electrical test after installation
Annex A (normative) Application of the abrasion test
Annex B (informative) Guidance on tests after installation
Provides a range of tests which may be required for electric cables which have an extruded oversheath and where that oversheath performs a special protective function.The standard covers cables for use in insulated systems and in uninsulated systems. The tests are categorized for use as routine tests, type tests and tests after installation.These tests comprise of electrical routine tests on cable oversheath used in insulated or uninsulated systems, abrasion and corrosion spread type tests, electrical test on cable oversheath after installation.Routine tests and tests after installation, as specified in the relevant cable standards, are applicable for all situations.Type tests depend upon the nature of the system and the construction of the cable and do not have to be carried out for normal conditions of use.The significant technical changes with respect to the previous edition are as follows: - The text has been modified in order to consider the function of the oversheath, irrespective of the way the metallic sheath or screen of the cable is earthed because, in some cases, the oversheath is designed to act not only as a protection against corrosion, but also to reduce the risk of degradation of the cable insulation system. This requirement may be independent of the nature of the insulation and independent of the rated voltage of the cable.- More precise wording has been introduced regarding the application of some tests (if the sheaths or foils are bonded to the oversheath or not).- The test requirements have been revised in order to be in line with the standards published after the second edition.- The pressure test at high temperature has been deleted as the requirement is specified in the relevant cable standards.- A "Guidance on tests after installation" (Annex B) has been included.
Committee |
TC 20
|
DevelopmentNote |
Stability Date: 2019. (09/2017)
|
DocumentType |
Standard
|
Pages |
22
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NF EN 60229 : 2008 | Identical |
NEN EN IEC 60229 : 2008 | Identical |
I.S. EN 60229:2008 | Identical |
PN EN 60229 : 2008 | Identical |
DIN EN 60229 : 2009 | Identical |
VDE 0473-229 : 2009 | Identical |
BS EN 60229:2008 | Identical |
CEI EN 60229 : 2010 | Identical |
EN 60229:2008 | Identical |
UNE-EN 60229:2009 | Identical |
DIN VDE 0472-807 : 1985 | Corresponds |
UNE 21143:1985 | Identical |
BS 7923:2004 | Electric cables. Internal gas-pressure cables and accessories for alternating voltages up to and including 275 kV (<i>U</i><sub>m</sub> = 300 kV). Requirements and test methods |
HD 633 S1:1997 | Tests on oil-filled (fluid filled), paper- or polypropylene paper laminate-insulated, metal-sheathed cables and accessories for alternating voltages up to and including 400 kV (Um = 420 kV) |
CEI 20-71 : 2003 | TESTS ON OIL-FILLED (FLUID FILLED), PAPER- AND PPL-INSULATED, METAL-SHEATHED CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 400 KV (UM = 420 KV) |
I.S. HD 632:2016 | POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV) |
17/30347740 DC : 0 | BS EN 63075 - SUPERCONDUCTING AC POWER CABLES AND THEIR ACCESSORIES FOR RATED VOLTAGES FROM 6 KV TO 500 KV - TEST METHODS AND REQUIREMENTS |
CEI EN 62271-204 : 2012 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 204: RIGID GAS-INSULATED TRANSMISSION LINES FOR RATED VOLTAGES ABOVE 52 KV |
I.S. HD 634:1999 | TESTS ON INTERNAL GAS-PRESSURE CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 275 KV (UM = 300 KV) |
I.S. HD 622:1999 | POWER CABLES HAVING RATED VOLTAGES FROM 3,6/6(7,2) KV UP TO AND INCLUDING 20,8/36(42) KV WITH SPECIAL FIRE PERFORMANCE FOR USE IN POWER STATIONS |
IEC 62067:2011 RLV | Power cables with extruded insulation and their accessories for rated voltages above 150 kV (<em>U</em><sub>m</sub> = 170 kV) up to 500 kV (<em>U</em><sub>m</sub> = 550 kV) - Test methods and requirements |
HD 620 : 2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV |
UNE-EN 62271-204:2012 | High-voltage switchgear and controlgear - Part 204: Rigid gas-insulated transmission lines for rated voltage above 52 kV |
BS IEC 62895:2017 | High voltage direct current (HVDC) power transmission. Cables with extruded insulation and their accessories for rated voltages up to 320 kV for land applications. Test methods and requirements |
14/30290103 DC : 0 | BS EN 62895 - HIGH VOLTAGE DIRECT CURRENT (HVDC) POWER TRANSMISSION CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES UP TO 320KV FOR LAND APPLICATIONS - TEST METHODS AND REQUIREMENTS |
UNE 211067-2:2017 | Power cables with extruded insulation and their accessories for rated voltages above 150 kV (Um = 170 kV) up to 400 kV (Um = 420 kV). Part 2: Cables with XLPE insulation and polyolefin compound sheath or high density polyethylene (HDPE) compound sheath. |
95/211874 DC : DRAFT SEP 1995 | PRHD 621 - MEDIUM VOLTAGE IMPREGNATED PAPER INSULATED DISTRIBUTION CABLES |
UNE 211632-4A:2017 | Power cables with extruded insulation and their accessories for rated voltages above 36 kV (Um = 42 kV) up to 150 kV (Um = 170 kV). Part 4A: Cables with XLPE insulation and polyolefin compound sheath (Types 1, 2 and 3) or high density polyethylene (HDPE) compound sheath. |
CEI 20-58 : 1999 | OVERHEAD DISTRIBUTION CABLES OF RATED VOLTAGE UO/U (UM): 0,6/1 (12) KV |
VDE 0276-621 : 1997 | POWER CABLES - PART 621: MEDIUM VOLTAGE IMPREGNATED PAPER INSULATED DISTRIBUTION CABLES |
NF EN 62271-204 : 2012 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 204: RIGID GAS-INSULATED TRANSMISSION LINES FOR RATED VOLTAGE ABOVE 52 KV |
IEC 60840:2011 RLV | Power cables with extruded insulation and their accessories for rated voltages above 30 kV (<em>U</em><sub>m</sub> = 36 kV) up to 150 kV (<em>U</em><sub>m</sub> = 170 kV) - Test methods and requirements |
DIN VDE 0276-633 : 1999 | TESTS ON OIL-FILLED (FLUID-FILLED), PAPER- AND POLYPROPYLENE PAPER LAMINATE-INSULATED, METAL-SHEATHED CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 400 KV (U[M] = 420 KV) |
VDE 0276-633 : 1999 | TESTS ON OIL-FILLED (FLUID-FILLED), PAPER- AND POLYPROPYLENE PAPER LAMINATE-INSULATED, METAL-SHEATHED CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 400 KV (U[M] = 420 KV) |
BS 7912:2001 | Power cables with XLPE insulation and metallic sheath, and their accessories, for rated voltages from 66 kV (<i>U</i><sub>m</sub>=72.5 kV) to 132kV (<i>U</i><sub>m</sub>=145kV). Requirements and test methods |
EA 0051:2014 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV. HPTE insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1, type 2 and type 3). |
IEC 60502-2:2014 RLV | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) – Part 2: Cables for rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) |
DIN VDE 0276-621 : 1997 | POWER CABLES - PART 621: MEDIUM VOLTAGE IMPREGNATED PAPER INSULATED DISTRIBUTION CABLES |
UNE-HD 620-10E:2012 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 10: XLPE insulated single core and 3 core cables, and single core pre-assembled cables. Section E: Cables with polyolefine compound sheath (types 10E-1, 10E-3, 10E-4 and 10E-5). |
UNE-HD 620-9E:2012 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 9: HEPR insulated single core cables, and single core pre-assembled cables. Section E: Cables with polyolefine compound sheath (types 9E-1, 9E-3, 9E-4 and 9E-5). |
EA 0052:2014 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV. HPTR insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1, type 2 and type 3). |
BS 7922:2004 | Electric cables. Fluid-filled, paper- and PPL-insulated, metal-sheathed cables and accessories for alternating voltages up to and including 400 kV (<i>U</i><sub>m</sub> = 420 kV). Requirements and test methods |
DIN VDE 0472-807 : 1985 | TESTING OF CABLES, WIRES AND FLEXIBLE CORDS; CORROSION |
I.S. HD 620:2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV |
IEC 60141-1:1993 | Tests on oil-filled and gas-pressure cables and their accessories - Part 1: Oil-filled, paper or polypropylene paper laminate insulated, metal-sheathed cables and accessories for alternating voltages up to and including 500 kV |
IEC 62271-204:2011 | High-voltage switchgear and controlgear - Part 204: Rigid gas-insulated transmission lines for rated voltage above 52 kV |
EN 62271-204:2011 | High-voltage switchgear and controlgear - Part 204: Rigid gas-insulated transmission lines for rated voltage above 52 kV |
HD 634 : 200S1 | TESTS ON INTERNAL GAS-PRESSURE CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 275 KV (UM = 300 KV) |
UNE 211632-6A:2017 | Power cables with extruded insulation and their accessories for rated voltages above 36 kV (Um = 42 kV) up to 150 kV (Um = 170 kV). Part 6A: Cables with HEPR insulation and polyolefin compound sheath (Types 1, 2 and 3) or high density polyethylene (HDPE) compound sheath. |
I.S. EN 62271-204:2011 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 204: RIGID GAS-INSULATED TRANSMISSION LINES FOR RATED VOLTAGE ABOVE 52 KV (IEC 62271-204:2011 (EQV)) |
03/318201 DC : DRAFT NOV 2003 | IEC 60502-2, ED.2 - POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES FROM 1 KV (UM = 1,2 KV) UP TO 30 KV (UM = 36 KV) - PART 2: CABLES FOR RATED VOLTAGES FROM 6 KV (UM = 7,2 KV) UP TO 30 KV (UM = 36 KV) |
BS EN 62271-204:2011 | High-voltage switchgear and controlgear Rigid gas-insulated transmission lines for rated voltage above 52 kV |
CEI 20-56 : 2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV SOMMARIO |
I.S. HD 633:1999 | TESTS ON OIL-FILLED (FLUID FILLED), PAPER- OR POLYPROPYLENE PAPER LAMINATED-INSULATED, METAL-SHEATHED CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 400 KV (UM = 420 KV) |
HD 622 S1:1996/A2:2005 | Power cables having rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV with special fire performance for use in power stations |
UNE-HD 620-1:2010 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 1: General requirements. |
IEC 60230:1966 | Impulse tests on cables and their accessories |
IEC 62230:2006+AMD1:2013 CSV | Electric cables - Spark-test method |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.