• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

IEC 60110-1:1998

Current

Current

The latest, up-to-date edition.

Power capacitors for induction heating installations - Part 1: General

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English - French, Spanish, Castilian

Published date

10-06-1998

£169.03
Excluding VAT

FOREWORD
1 General
    1.1 Scope and object
    1.2 Normative references
    1.3 Definitions
    1.4 Service conditions
2 Quality requirements and tests
    2.1 Test requirements
    2.2 Classification of tests
    2.3 Capacitance measurement
    2.4 Measurement of the tangent of the loss angle
          of a capacitor
    2.5 Voltage test between terminals (routine test)
    2.6 Voltage test between terminals and container
    2.7 Test on internal discharge device
    2.8 Sealing test
    2.9 Thermal stability test
    2.10 Capacitor losses test
    2.11 Capacitance as a function of temperature
    2.12 Sealing test of cooling ducts, if any
    2.13 Self-healing test (for self-healing metallized
          dielectric capacitors)
    2.14 Short-circuit discharge test
    2.15 Ageing test (see IEC 60110-2)
    2.16 Destruction test (see IEC 60110-2)
    2.17 Disconnecting tests on internal fuses, if any
          (see IEC 60110-2)
3 Overloads
    3.1 Maximum permissible voltage
    3.2 Switching voltages
    3.3 Maximum permissible current
4 Safety requirements
    4.1 Creepage distances
    4.2 Discharge device
    4.3 Container connections
    4.4 Protection of the environment
    4.5 Additional safety requirements
5 Markings
    5.1 Marking of the capacitor unit
    5.2 Marking of the bank
6 Guide for installation and operation
    6.1 General
    6.2 Measures to obtain adequate cooling
    6.3 Choice of rated voltage, current and output
    6.4 Capacitors for frequent switching on load
    6.5 Choice of the highest voltage for equipment of
          a capacitor bank
    6.9 Shunt capacitors connected in series
    6.10 Series capacitors
    6.11 Connecting leads
    6.12 Live parts along water supply
    6.13 Post insulators
    6.14 Danger of freezing for water cooled capacitors
Annex A (normative) Methods of measuring the losses on
air-cooled self-and forced-ventilated capacitors
Annex B (informative) Formulae for capacitors and
installations
Annex C (informative) Bibliography

Is applicable both to indoor capacitor units and indoor capacitor banks intended to be used, particularly, for power factor correction in induction heating, melting, stirring or casting installations, and similar applications with controlled or adjustable a.c. voltage systems in a frequency range up to 50 kHz, and with a rated voltage not exceeding 3,6 kV.

Committee
TC 33
DevelopmentNote
Supersedes IEC 60110 (03/2001) Supersedes IEC 60594. (06/2004) Also numbered as BS EN 60110-1 (05/2005) Stability Date: 2020. (09/2017)
DocumentType
Standard
Pages
59
PublisherName
International Electrotechnical Committee
Status
Current
Supersedes

09/30173454 DC : 0 BS EN 61881-1 - RAILWAY APPLICATIONS - ROLLING STOCK EQUIPMENT - CAPACITORS FOR POWER ELECTRONICS - PART 1: REQUIREMENTS, TESTS AND GENERAL INFORMATION
CEI EN 61881-1 : 2012 RAILWAY APPLICATIONS - ROLLING STOCK EQUIPMENT - CAPACITORS FOR POWER ELECTRONICS - PART 1: PAPER/PLASTIC FILM CAPACITORS
I.S. EN 60252-1:2011 AC MOTOR CAPACITORS - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDANCE FOR INSTALLATION AND OPERATION (IEC 60252-1:2010 (EQV))
UNE-EN 60252-1:2011 AC motor capacitors -- Part 1: General - Performance, testing and rating - Safety requirements - Guidance for installation and operation
BS EN 60871-1:2014 Shunt capacitors for a.c. power systems having a rated voltage above 1 000 V General
I.S. EN 61071:2007 CAPACITORS FOR POWER ELECTRONICS
I.S. EN 61881-1:2011 RAILWAY APPLICATIONS - ROLLING STOCK EQUIPMENT - CAPACITORS FOR POWER ELECTRONICS - PART 1: PAPER/PLASTIC FILM CAPACITORS
BS EN 60252-1 : 2011 AC MOTOR CAPACITORS - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDANCE FOR INSTALLATION AND OPERATION
IEC 60143-1:2015 Series capacitors for power systems - Part 1: General
08/30195433 DC : 0 BS EN 60519-1 - SAFETY IN ELECTROHEAT INSTALLATIONS - PART 1: GENERAL REQUIREMENTS
BS EN 60519-11:2007 Safety in electroheat installations Particular requirements for installations using the effect of electromagnetic forces on liquid metals
EN 61881-1:2011 Railway applications - Rolling stock equipment - Capacitors for power electronics - Part 1: Paper/plastic film capacitors
EN 60831-1:2014/AC:2014 SHUNT POWER CAPACITORS OF THE SELF-HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AND INCLUDING 1000 V - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDE FOR INSTALLATION AND OPERATION
EN 60252-1 : 2011 AMD 1 2013 AC MOTOR CAPACITORS - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDANCE FOR INSTALLATION AND OPERATION (IEC 60252-1:2010/A1:2013)
EN 60143-1:2015/AC:2017-05 Series capacitors for power systems - Part 1: General
14/30310457 DC : 0 BS EN 60143-1 - SERIES CAPACITORS FOR POWER SYSTEMS - PART 1: GENERAL
BS EN 61881-1:2011 Railway applications. Rolling stock equipment. Capacitors for power electronics Paper/plastic film capacitors
18/30366694 DC BS EN 60519-3. Safety in installations for electroheating and electromagnetic processing Part 3. Particular requirements for inductively coupled and resistive equipment and processing installations
I.S. EN 60519-3:2005 SAFETY IN ELECTROHEAT INSTALLATIONS - PART 3: PARTICULAR REQUIREMENTS FOR INDUCTION AND CONDUCTION HEATING AND INDUCTION MELTING INSTALLATIONS
CEI EN 60871-1 : 2015 SHUNT CAPACITORS FOR A.C. POWER SYSTEMS HAVING A RATED VOLTAGE ABOVE 1000 V - PART 1: GENERAL
I.S. EN 60831-1:2014-2015-10 SHUNT POWER CAPACITORS OF THE SELF-HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AND INCLUDING 1000 V - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDE FOR INSTALLATION AND OPERATION
IEC 60519-11:2007 Safety in electroheat installations - Part 11: Particular requirements for installations using the effect of electromagnetic forces on liquid metals
BS EN 60519-3:2005 Safety in electroheat installations Particular requirements for induction and conduction heating and induction melting installations
BS EN 61071:2007 Capacitors for power electronics
IEC 61071:2017 Capacitors for power electronics
13/30277685 DC : 0 BS EN 60519-1 - SAFETY IN INSTALLATIONS FOR ELECTROHEATING AND ELECTROMAGNETIC PROCESSING - PART 1: GENERAL REQUIREMENTS
IEC 60871-1:2014 Shunt capacitors for a.c. power systems having a rated voltage above 1 000 V - Part 1: General
IEC 60831-1:2014 RLV Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 000 V - Part 1: General - Performance, testing and rating - Safety requirements - Guide for installation and operation
IEC 60519-3:2005 Safety in electroheat installations - Part 3: Particular requirements for induction and conduction heating and induction melting installations
IEC 61881-1:2010 Railway applications - Rolling stock equipment - Capacitors for power electronics - Part 1: Paper/plastic film capacitors
IEC 60252-1:2010+AMD1:2013 CSV AC motor capacitors - Part 1: General - Performance, testing andrating - Safety requirements - Guidance for installation and operation
I.S. EN 60871-1:2014 SHUNT CAPACITORS FOR A.C. POWER SYSTEMS HAVING A RATED VOLTAGE ABOVE 1000 V - PART 1: GENERAL
BS EN 60831-1:2014 Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 000 V General. Performance, testing and rating. Safety requirements. Guide for installation and operation
CEI EN 61071 : 2007 CAPACITORS FOR POWER ELECTRONICS
BS EN 60143-1:2015 Series capacitors for power systems General
I.S. EN 60143-1:2015 SERIES CAPACITORS FOR POWER SYSTEMS - PART 1: GENERAL
I.S. EN 60519-11:2007 SAFETY IN ELECTROHEAT INSTALLATIONS - PART 11: PARTICULAR REQUIREMENTS FOR INSTALLATIONS USING THE EFFECT OF ELECTROMAGNETIC FORCES ON LIQUID METALS
IEC TS 60110-2:2000 Power capacitors for induction heating installations - Part 2: Ageing test, destruction test and requirements for disconnecting internal fuses
IEC 61071:2017 RLV Capacitors for power electronics
EN 60519-3:2005 Safety in electroheat installations - Part 3: Particular requirements for induction and conduction heating and induction melting installations
EN 61071:2007 Capacitors for power electronics
EN 60871-1:2014 Shunt capacitors for a.c. power systems having a rated voltage above 1 000 V - Part 1: General
EN 60519-11:2007 Safety in electroheat installations - Part 11: Particular requirements for installations using the effect of electromagnetic forces on liquid metals
CSA C60871.1 : 2014 SHUNT CAPACITORS FOR A.C. POWER SYSTEMS HAVING A RATED VOLTAGE ABOVE 1000 V - PART 1: GENERAL

IEC TR 60996:1989 Method for verifying accuracy of tan delta measurements applicable to capacitors
IEC 60143:1972 Series capacitors for power systems
IEC 60050-436:1990 International Electrotechnical Vocabulary (IEV) - Part 436: Power capacitors

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.