I.S. EN 80369-5:2016

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

SMALL-BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 5: CONNECTORS FOR LIMB CUFF INFLATION APPLICATIONS

Available format(s)

Hardcopy , PDF

Superseded date

24-07-2021

Language(s)

English

Published date

01-01-2017

Preview

For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.

Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

£54.77
Excluding VAT

National Foreword
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 Dimensional requirements for
  sphygmomanometer and cuff SMALL-BORE CONNECTORS
6 Performance requirements
Annex A (informative) - Rationale and guidance
Annex B (normative) - SMALL-BORE CONNECTORS for
        the limb cuff inflation APPLICATION
Annex C (normative) - Reference CONNECTORS
Annex D (informative) - Assessment of MEDICAL
        DEVICES and their attributes with CONNECTIONS
        within this APPLICATION
Annex E (informative) - Summary of the usability
        requirements for SMALL-BORE CONNECTORS for
        limb cuff inflation APPLICATIONS
Annex F (informative) - Summary of SMALL-BORE
        CONNECTOR design requirements for limb cuff
        inflation APPLICATIONS
Annex G (informative) - Summary of assessment
        of the design of the CONNECTORS for limb cuff
        inflation APPLICATION
Annex H (informative) - Obsolete limb cuff inflation
        CONNECTOR
Annex I (informative) - Air leakage by pressure decay
        TEST METHOD
Annex J (informative) - Resistance to separation from
        axial load TEST METHOD
Annex K (informative) - Reference to the essential principles
Index of defined terms
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications
Annex ZZ (informative) - Relationship between this
         European standard and the essential
         requirements of Directive 93/42/EEC
         [OJ L 169] aimed to be covered

Defines dimensions and requirements for the design and functional performance of SMALL-BORE CONNECTORS intended to be used for CONNECTIONS in limb cuff inflation APPLICATIONS of MEDICAL DEVICES and ACCESSORIES.

DevelopmentNote
2016 Edition issued incorporating corrigendum 2017. (05/2017)
DocumentType
Standard
Pages
104
PublisherName
National Standards Authority of Ireland
Status
Superseded
SupersededBy

ISO 80369-20:2015 Small-bore connectors for liquids and gases in healthcare applications Part 20: Common test methods
EN ISO 5356-1:2015 Anaesthetic and respiratory equipment - Conical connectors - Part 1: Cones and sockets (ISO 5356-1:2015)
ISO 81060-1:2007 Non-invasive sphygmomanometers — Part 1: Requirements and test methods for non-automated measurement type
EN ISO 80369-1:2010 Small bore connectors for liquids and gases in healthcare applications - Part 1: General requirements (ISO 80369-1:2010)
ISO 5356-1:2015 Anaesthetic and respiratory equipment Conical connectors Part 1: Cones and sockets
ANSI B11 : 2008 GENERAL SAFETY REQUIREMENTS COMMON TO ANSI B11 MACHINES
ISO 3040:2016 Geometrical product specifications (GPS) Dimensioning and tolerancing Cones
ISO 5356-2:2012 Anaesthetic and respiratory equipment — Conical connectors — Part 2: Screw-threaded weight-bearing connectors
CR 13825:2000 Luer connectors - A report to CEN chef from the CEN forum task group "Luer fittings"
ISO 8185:2007 Respiratory tract humidifiers for medical use Particular requirements for respiratory humidification systems
ISO/TR 16142:2006 Medical devices Guidance on the selection of standards in support of recognized essential principles of safety and performance of medical devices
ISO 80369-6:2016 Small bore connectors for liquids and gases in healthcare applications — Part 6: Connectors for neuraxial applications
ASTM D 790 : 2017 : REDLINE Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials
IEC 80601-2-30:2009+AMD1:2013 CSV Medical electrical equipment - Part 2-30: Particular requirements for the basic safety and essential performance of automated non-invasive sphygmomanometers
EN ISO 5356-2:2012 Anaesthetic and respiratory equipment - Conical connectors - Part 2: Screw-threaded weight-bearing connectors (ISO 5356-2:2012)
ISO 80369-1:2010 Small-bore connectors for liquids and gases in healthcare applications Part 1: General requirements
EN ISO 14971:2012 Medical devices - Application of risk management to medical devices (ISO 14971:2007, Corrected version 2007-10-01)
ISO 14971:2007 Medical devices Application of risk management to medical devices
EN ISO 8185:2009 Respiratory tract humidifiers for medical use - Particular requirements for respiratory humidification systems (ISO 8185:2007)
ISO 594-2:1998 Conical fittings with 6 % (Luer) taper for syringes, needles and certain other medical equipment Part 2: Lock fittings
ISO 594-1:1986 Conical fittings with a 6 % (Luer) taper for syringes, needles and certain other medical equipment Part 1: General requirements
ASTM D 638 : 2014 : REDLINE Standard Test Method for Tensile Properties of Plastics
ISO 80369-3:2016 Small-bore connectors for liquids and gases in healthcare applications — Part 3: Connectors for enteral applications

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.