I.S. EN 80369-5:2016
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
SMALL-BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 5: CONNECTORS FOR LIMB CUFF INFLATION APPLICATIONS
Hardcopy , PDF
24-07-2021
English
01-01-2017
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
National Foreword
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 Dimensional requirements for
sphygmomanometer and cuff SMALL-BORE CONNECTORS
6 Performance requirements
Annex A (informative) - Rationale and guidance
Annex B (normative) - SMALL-BORE CONNECTORS for
the limb cuff inflation APPLICATION
Annex C (normative) - Reference CONNECTORS
Annex D (informative) - Assessment of MEDICAL
DEVICES and their attributes with CONNECTIONS
within this APPLICATION
Annex E (informative) - Summary of the usability
requirements for SMALL-BORE CONNECTORS for
limb cuff inflation APPLICATIONS
Annex F (informative) - Summary of SMALL-BORE
CONNECTOR design requirements for limb cuff
inflation APPLICATIONS
Annex G (informative) - Summary of assessment
of the design of the CONNECTORS for limb cuff
inflation APPLICATION
Annex H (informative) - Obsolete limb cuff inflation
CONNECTOR
Annex I (informative) - Air leakage by pressure decay
TEST METHOD
Annex J (informative) - Resistance to separation from
axial load TEST METHOD
Annex K (informative) - Reference to the essential principles
Index of defined terms
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Annex ZZ (informative) - Relationship between this
European standard and the essential
requirements of Directive 93/42/EEC
[OJ L 169] aimed to be covered
Defines dimensions and requirements for the design and functional performance of SMALL-BORE CONNECTORS intended to be used for CONNECTIONS in limb cuff inflation APPLICATIONS of MEDICAL DEVICES and ACCESSORIES.
DevelopmentNote |
2016 Edition issued incorporating corrigendum 2017. (05/2017)
|
DocumentType |
Standard
|
Pages |
104
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy |
ISO 80369-20:2015 | Small-bore connectors for liquids and gases in healthcare applications Part 20: Common test methods |
EN ISO 5356-1:2015 | Anaesthetic and respiratory equipment - Conical connectors - Part 1: Cones and sockets (ISO 5356-1:2015) |
ISO 81060-1:2007 | Non-invasive sphygmomanometers — Part 1: Requirements and test methods for non-automated measurement type |
EN ISO 80369-1:2010 | Small bore connectors for liquids and gases in healthcare applications - Part 1: General requirements (ISO 80369-1:2010) |
ISO 5356-1:2015 | Anaesthetic and respiratory equipment Conical connectors Part 1: Cones and sockets |
ANSI B11 : 2008 | GENERAL SAFETY REQUIREMENTS COMMON TO ANSI B11 MACHINES |
ISO 3040:2016 | Geometrical product specifications (GPS) Dimensioning and tolerancing Cones |
ISO 5356-2:2012 | Anaesthetic and respiratory equipment — Conical connectors — Part 2: Screw-threaded weight-bearing connectors |
CR 13825:2000 | Luer connectors - A report to CEN chef from the CEN forum task group "Luer fittings" |
ISO 8185:2007 | Respiratory tract humidifiers for medical use Particular requirements for respiratory humidification systems |
ISO/TR 16142:2006 | Medical devices Guidance on the selection of standards in support of recognized essential principles of safety and performance of medical devices |
ISO 80369-6:2016 | Small bore connectors for liquids and gases in healthcare applications — Part 6: Connectors for neuraxial applications |
ASTM D 790 : 2017 : REDLINE | Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials |
IEC 80601-2-30:2009+AMD1:2013 CSV | Medical electrical equipment - Part 2-30: Particular requirements for the basic safety and essential performance of automated non-invasive sphygmomanometers |
EN ISO 5356-2:2012 | Anaesthetic and respiratory equipment - Conical connectors - Part 2: Screw-threaded weight-bearing connectors (ISO 5356-2:2012) |
ISO 80369-1:2010 | Small-bore connectors for liquids and gases in healthcare applications Part 1: General requirements |
EN ISO 14971:2012 | Medical devices - Application of risk management to medical devices (ISO 14971:2007, Corrected version 2007-10-01) |
ISO 14971:2007 | Medical devices Application of risk management to medical devices |
EN ISO 8185:2009 | Respiratory tract humidifiers for medical use - Particular requirements for respiratory humidification systems (ISO 8185:2007) |
ISO 594-2:1998 | Conical fittings with 6 % (Luer) taper for syringes, needles and certain other medical equipment Part 2: Lock fittings |
ISO 594-1:1986 | Conical fittings with a 6 % (Luer) taper for syringes, needles and certain other medical equipment Part 1: General requirements |
ASTM D 638 : 2014 : REDLINE | Standard Test Method for Tensile Properties of Plastics |
ISO 80369-3:2016 | Small-bore connectors for liquids and gases in healthcare applications — Part 3: Connectors for enteral applications |