I.S. EN 62310-2:2007
Current
The latest, up-to-date edition.
STATIC TRANSFER SYSTEMS (STS) - PART 2: ELECTROMAGNETIC COMPATIBILITY (EMC) REQUIREMENTS
Hardcopy , PDF
English
01-01-2007
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
3.1 General definitions
3.2 Circuit characteristics - Specified values
3.3 EMC definitions
3.4 Environments
4 STS categories
4.1 STS of category C1
4.2 STS of category C2
4.3 STS of category C3
4.4 STS of category C4
4.5 Categories and environment
5 Emission
5.1 General requirements
5.2 General measurement conditions
5.3 Conducted emissions
5.4 Radiated emissions
6 Immunity
6.1 General requirements and performance criteria
6.2 Basic immunity requirements - high-frequency disturbances
6.3 Immunity to low-frequency signals
6.4 Immunity to power frequency magnetic field
6.5 Immunity to voltage dips, short interruptions and voltage
variations
Annex A (normative) Electromagnetic emission - Test methods
Annex B (informative) Electromagnetic emission limits of magnetic
field - H field
Annex C (informative) Electromagnetic emission - Limits of signal
ports
Annex D (normative) Electromagnetic immunity - Test methods
Annex E (informative) User installation testing (in situ testing)
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Annex ZZ (informative) Coverage of Essential Requirements of EC
Directives
Bibliography
Pertains to free standing operation a.c. static transfer systems (STS) intended to ensure the continuity of load supply through controlled transfer, with or without interruption of power, from two or more independent a.c. sources.
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
77
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Standards | Relationship |
NF EN 62310-2 : 2007 | Identical |
DIN EN 62310-2 : 2007 | Identical |
NBN EN 62310-2 : 2007 | Identical |
BS EN 62310-2:2007 | Identical |
EN 62310-2:2007 | Identical |
IEC 62310-2:2006 | Identical |
EN 61000-4-1:2007 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
IEC 61000-4-1:2006 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
CISPR 16-1-1:2015 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus |
IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 62310-1:2005 | Static transfer systems (STS) - Part 1: General and safety requirements |
CISPR 16-1-5:2014+AMD1:2016 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration sites and reference test sites for 5 MHz to 18 GHz |
EN 62310-1:2005 | Static transfer systems (STS) - Part 1: General and safety requirements |
CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
EN 61000-2-2:2002/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS (IEC 61000-2-2:2002/A1:2017) |
EN 55016-1-5:2015/A1:2017 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-5: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNA CALIBRATION SITES AND REFERENCE TEST SITES FOR 5 MHZ TO 18 GHZ (CISPR 16-1-5:2014/A1:2016) |
EN 55022:2010/AC:2011 | INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008) |
EN 61000-4-8:2010 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 61000-2-2:2002+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems |
EN 61000-3-2:2014 | Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase) |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
IEC 60947-6-1:2005+AMD1:2013 CSV | Low-voltage switchgear and controlgear - Part 6-1: Multiple functionequipment - Transfer switching equipment |
EN 55016-1-1:2010/A2:2014 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS (CISPR 16-1-1:2010/A2:2014) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.