I.S. EN 62232:2017
Current
The latest, up-to-date edition.
DETERMINATION OF RF FIELD STRENGTH, POWER DENSITY AND SAR IN THE VICINITY OF RADIOCOMMUNICATION BASE STATIONS FOR THE PURPOSE OF EVALUATING HUMAN EXPOSURE
Hardcopy , PDF
English
01-01-2017
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
National Foreword
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviated terms
5 Quick start guide and how to use this document
6 Evaluation processes for product compliance,
product installation compliance and in-situ RF
exposure assessments
7 Determining the evaluation method
8 Evaluation methods
9 Uncertainty
10 Reporting
Annex A (informative) - Source environment plane and
guidance on the evaluation method selection
Annex B (normative) - Evaluation methods
Annex C (informative) - Rationale supporting simplified
product installation criteria
Annex D (informative) - Guidance on comparing evaluated
parameters with a limit value
Annex E (informative) - Uncertainty
Annex F (informative) - Technology-specific guidance
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Gives methods for the determination of radio-frequency (RF) field strength and specific absorption rate (SAR) in the vicinity of radiocommunication base stations (RBS) for the purpose of evaluating human exposure.
DevelopmentNote |
Supersedes I.S. EN 50383, I.S. EN 50400 and I.S. EN 50492. For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (12/2017)
|
DocumentType |
Standard
|
Pages |
254
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
IEC 60050-394:2007 | International Electrotechnical Vocabulary (IEV) - Part 394: Nuclear instrumentation - Instruments, systems, equipment and detectors |
IEC 62209-2:2010 | Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures - Part 2: Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body (frequency range of 30 MHz to 6 GHz) |
EN 62311:2008 | Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz - 300 GHz) |
CISPR 16-4-2:2011+AMD1:2014 CSV | Specification for radio disturbance and immunity measuring apparatusand methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty |
IEC 62209-1:2016 | Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz) |
IEC 62479:2010 | Assessment of the compliance of low-power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz) |
IEEE C95.3-2002 | IEEE Recommended Practice for Measurements and Computations of Radio Frequency Electromagnetic Fields With Respect to Human Exposure to Such Fields, 100 kHz-300 GHz |
IEC TR 62630:2010 | Guidance for evaluating exposure from multiple electromagnetic sources |
IEEE C95.1-2005 | IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz |
IEC 62311:2007 | Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz - 300 GHz) |
EN 62479:2010 | Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz) |
EN 62209-1:2016 | Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz) |
IEEE 145-2013 REDLINE | IEEE Standard for Definitions of Terms for Antennas |
IEC 60050-121:1998 | International Electrotechnical Vocabulary (IEV) - Part 121: Electromagnetism |
EN 62209-2:2010 | HUMAN EXPOSURE TO RADIO FREQUENCY FIELDS FROM HAND-HELD AND BODYMOUNTED WIRELESS COMMUNICATION DEVICES - HUMAN MODELS, INSTRUMENTATION, AND PROCEDURES - PART 2: PROCEDURE TO DETERMINE THE SPECIFIC ABSORPTION RATE (SAR) FOR WIRELESS COMMUNICATION DEVICES USED IN CLOSE PROXIMITY TO THE HUMAN BODY (FREQUENCY RANGE OF 30 MHZ TO 6 GHZ) |
TR 102 457 : 1.1.1 | TRANSMISSION AND MULTIPLEXING (TM); STUDY ON THE ELECTROMAGNETIC RADIATED FIELD IN FIXED RADIO SYSTEMS FOR ENVIRONMENTAL ISSUES |
IEC 60050-705:1995 | International Electrotechnical Vocabulary (IEV) - Part 705: Radio wave propagation |
IEC 60050-712:1992 | International Electrotechnical Vocabulary (IEV) - Part 712: Antennas |
IEC TR 62669:2011 | Case studies supporting IEC 62232 - Determination of RF field strength and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.