I.S. EN 60300-3-4:2008
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
DEPENDABILITY MANAGEMENT - PART 3-4: APPLICATION GUIDE - GUIDE TO THE SPECIFICATION OF DEPENDABILITY REQUIREMENTS
Hardcopy , PDF
13-05-2022
English
01-01-2008
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General considerations for dependability specifications
4.1 The need for dependability
4.2 Requirements and goals
4.3 Systems
4.4 Demonstration of achievement of requirements
4.4.1 Concept
4.4.2 Activities
4.5 Contracting for dependability
4.6 Types of specification
4.7 Derivation of dependability specifications
5 Dependability management
6 Availability
6.1 General
6.1.1 Choice of dependability characteristic
6.1.2 Relationship between availability, reliability
and maintainability
6.2 Availability specifications
6.2.1 Quantitative requirements
6.2.2 Qualitative requirements
6.3 Provision of availability verification and validation
6.3.1 General
6.3.2 Verification and validation by testing
6.3.3 Verification and validation by analysis
7 Reliability
7.1 General
7.2 Reliability specification
7.2.1 Quantitative requirements
7.2.2 Qualitative requirements
7.3 Reliability verification and validation
7.3.1 General
7.3.2 Verification and validation by testing
7.3.3 Verification and validation by analysis
8 Maintainability
8.1 General
8.2 Maintainability specification
8.2.1 Quantitative requirements
8.2.2 Qualitative requirements
8.3 Maintainability verification and validation
9 Maintenance support
9.1 General
9.2 Maintenance support specification
9.2.1 Quantitative requirements
9.2.2 Qualitative requirements
9.3 Maintenance support verification and validation
Annex A (informative) Reference standards for verification
and validation techniques
Annex B (informative) Examples of reliability, maintainability,
maintenance support and availability requirements
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Bibliography
Presents guidance on specifying the required dependability characteristics in specifications, together with specifications of procedures and criteria for verification and validation.
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
84
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
IEC 60300-3-4:2007 | Identical |
EN 60300-3-4:2008 | Identical |
IEC 61025:2006 | Fault tree analysis (FTA) |
IEC 60605-3-5:1996 | Equipment reliability testing - Part 3: Preferred test conditions - Section 5: Test cycle 5: Ground mobile equipment - Low degree of simulation |
DEFSTAN 00-42(PT3)/2(2003) : 2003 | RELIABILITY AND MAINTAINABILITY (R&M) ASSURANCE GUIDANCE - PART 3: R&M CASE |
IEC 60605-3-2:1986 | Equipment reliability testing. Part 3: Preferred test conditions. Equipment for stationary use in weatherprotected locations - High degree of simulation |
IEC 61123:1991 | Reliability testing - Compliance test plans for success ratio |
IEC 60605-4:2001 | Equipment reliability testing - Part 4: Statistical procedures for exponential distribution - Point estimates, confidence intervals, prediction intervals and tolerance intervals |
IEC 62308:2006 | Equipment reliability - Reliability assessment methods |
IEC 60605-3-6:1996 | Equipment reliability testing - Part 3: Preferred test conditions - Section 6: Test cycle 6: Outdoor transportable equipment - Low degree of simulation |
IEC 60605-3-3:1992 | Equipment reliability testing - Part 3: Preferred test conditions - Section 3: Test Cycle 3: Equipment for stationary use in partially weatherprotected locations - Low degree of simulation |
IEC 62198:2013 | Managing risk in projects - Application guidelines |
EN 60300-3-2:2005 | Dependability management - Part 3-2: Application guide - Collection of dependability data from the field |
IEC 60812:2006 | Analysis techniques for system reliability - Procedure for failure mode and effects analysis (FMEA) |
IEC 60300-3-3:2017 | Dependability management - Part 3-3: Application guide - Life cycle costing |
IEC 61649:2008 | Weibull analysis |
IEC 60300-3-12:2011 | Dependability management - Part 3-12: Application guide - Integrated logistic support |
IEC 60605-3-4:1992 | Equipment reliability testing - Part 3: Preferred test conditions - Section 4: Test cycle 4: Equipment for portable and non-stationary use - Low degree of simulation |
IEC 61014:2003 | Programmes for reliability growth |
IEC 60300-3-14:2004 | Dependability management - Part 3-14: Application guide - Maintenance and maintenance support |
IEC 60605-6:2007 | Equipment reliability testing - Part 6: Tests for the validity and estimation of the constant failure rate and constant failure intensity |
IEC 60706-3:2006 | Maintainability of equipment - Part 3: Verification and collection, analysis and presentation of data |
EN 60300-1:2014 | Dependability management - Part 1: Guidance for management and application |
IEC 61160:2005 | Design review |
EN 60706-2:2006 | Maintainability of equipment - Part 2: Maintainability requirements and studies during the design and development phase |
IEC 61070:1991 | Compliance test procedures for steady-state availability |
IEC 61508-5:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 5: Examples of methods for the determination of safety integrity levels (see Functional Safety and IEC 61508) |
IEC 61078:2016 | Reliability block diagrams |
IEC 61165:2006 | Application of Markov techniques |
IEC 61508-4:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 4: Definitions and abbreviations (see Functional Safety and IEC 61508) |
IEC 61508-3:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements (see Functional Safety and IEC 61508) |
IEC 60605-3-1:1986 | Equipment reliability testing. Part 3: Preferred test conditions. Indoor portable equipment - Low degree of simulation |
EN 60706-3:2006 | Maintainability of equipment - Part 3: Verification and collection, analysis and presentation of data |
EN 62347:2007 | Guidance on system dependability specifications |
EN 60300-3-1:2004 | Dependability management - Part 3-1: Application guide - Analysis techniques for dependability - Guide on methodology |
EN 60300-3-12:2011 | Dependability management - Part 3-12: Application guide - Integrated logistic support |
EN 61078 : 1991 | RELIABILITY BLOCK DIAGRAMS (IEC 61078:2016) |
EN 60300-3-14:2004 | Dependability management - Part 3-14: Application guide - Maintenance and maintenance support |
EN 60300-3-3:2017 | Dependability management - Part 3-3: Application guide - Life cycle costing |
IEC 62347:2006 | Guidance on system dependability specifications |
IEC 60300-3-2:2004 | Dependability management - Part 3-2: Application guide - Collection of dependability data from the field |
IEC 61124:2012 | Reliability testing - Compliance tests for constant failure rate and constant failure intensity |
IEC 60300-3-1:2003 | Dependability management - Part 3-1: Application guide - Analysis techniques for dependability - Guide on methodology |
IEC 61164:2004 | Reliability growth - Statistical test and estimation methods |
IEC 61703:2016 | Mathematical expressions for reliability, availability, maintainability and maintenance support terms |
IEC 61709:2017 | Electric components - Reliability - Reference conditions for failure rates and stress models for conversion |
EN 61025:2007 | Fault tree analysis (FTA) |
IEC 60300-1:2014 | Dependability management - Part 1: Guidance for management and application |
IEC 60605-2:1994 | Equipment reliability testing - Part 2: Design of test cycles |
IEC 60706-2:2006 | Maintainability of equipment - Part 2: Maintainability requirements and studies during the design and development phase |
IEC 60300-2:2004 | Dependability management - Part 2: Guidelines for dependability management |
IEC 60300-3-10:2001 | Dependability management - Part 3-10: Application guide - Maintainability |
IEC 61713:2000 | Software dependability through the software life-cycle processes- Application guide |
EN 61014:2003 | Programmes for reliability growth |
IEC 60706-5:2007 | Maintainability of equipment - Part 5: Testability and diagnostic testing |
IEC 61508-6:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 6: Guidelines on the application of IEC 61508-2 and IEC 61508-3 (see Functional Safety and IEC 61508) |
EN 61160:2005 | Design review |
IEC 61508-1:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements (see Functional Safety and IEC 61508) |
IEC TR 61508-0:2005 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 0: Functional safety and IEC 61508 (see Functional Safety and IEC 61508) |
IEC 61650:1997 | Reliability data analysis techniques - Procedures for comparison of two constant failure rates and two constant failure (event) intensities |
EN 61164:2004 | Reliability growth - Statistical test and estimation methods |
IEC 61508-7:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 7: Overview of techniques and measures (see Functional Safety and IEC 61508) |
EN 60300-2:2004 | Dependability management - Part 2: Guidelines for dependability management |
EN 62308 : 2006 | EQUIPMENT RELIABILITY - RELIABILITY ASSESSMENT METHODS |
EN 61124:2012 | RELIABILITY TESTING - COMPLIANCE TESTS FOR CONSTANT FAILURE RATE AND CONSTANT FAILURE INTENSITY (IEC 61124:2012) |
EN 60706-5:2007 | Maintainability of equipment - Part 5: Testability and diagnostic testing |
IEC 61508-2:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 2: Requirements for electrical/electronic/programmable electronic safety-related systems (see Functional Safety and IEC 61508) |
IEC 61710:2013 | Power law model - Goodness-of-fit tests and estimation methods |
EN 61703:2016 | Mathematical expressions for reliability, availability, maintainability and maintenance support terms |
IEC 60300-3-5:2001 | Dependability management - Part 3-5: Application guide - Reliability test conditions and statistical test principles |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.