I.S. EN 60099-5:2013
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS (IEC 60099-5:2013 (EQV))
Hardcopy , PDF
23-02-2021
English
01-01-2013
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 General principles for the application of surge
arresters
5 Surge arrester fundamentals and applications issues
6 Insulation coordination and surge arrester
applications
7 Surge arresters for special applications
8 Asset management of surge arresters
Annex A (informative) - Determination of temporary
overvoltages due to earth faults
Annex B (informative) - Current practice
Annex C (informative) - Arrester modelling techniques
for studies involving insulation coordination
and energy requirements
Annex D (informative) - Diagnostic indicators of
metal-oxide surge arresters in service
Annex E (informative) - Typical data needed from arrester
manufacturers for proper selection of surge
arresters
Annex F (informative) - Typical maximum residual
voltages for metal-oxide arresters without gaps
according to IEC 60099-4
Annex G (informative) - Steepness reduction of
incoming surge with additional line terminal
surge capacitance
Annex H (informative) - End of life and replacement
of old gapped SiC-arresters
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Gives information, guidance, and recommendations for the selection and application of surge arresters to be used in three-phase systems with nominal voltages above 1 kV.
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
151
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Withdrawn
|
Standards | Relationship |
UNE-EN 60099-5:2000 | Identical |
NBN EN 60099-5 : 2013 | Identical |
BS EN 60099-5:2013 | Identical |
NF EN 60099-5 : 2017 | Identical |
DIN EN 60099-5 : 2014 | Identical |
EN 60099-5:2013 | Identical |
SN EN 60099-5 : 1996 AMD 1 1999 | Identical |
IEC 62271-200:2011 | High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
EN 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
IEC 60099-4:2014 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
IEC TR 60071-4:2004 | Insulation co-ordination - Part 4: Computational guide to insulation co-ordination and modelling of electrical networks |
IEC TS 60815-2:2008 | Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 2: Ceramic and glass insulators for a.c. systems |
EN 62271-203:2012 | High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV |
IEC TR 62271-300:2006 | High-voltage switchgear and controlgear - Part 300: Seismic qualification of alternating current circuit-breakers |
EN 60099-4:2014 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
IEC 60099-6:2002 | Surge arresters - Part 6: Surge arresters containing both series and parallel gapped structures - Rated 52 kV and less |
EN 60507:2014 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems |
IEC 62271-203:2011 | High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV |
EN 60071-1:2006/A1:2010 | INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES |
IEC 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
IEC 60071-2:1996 | Insulation co-ordination - Part 2: Application guide |
IEC 60099-8:2017 | Surge arresters - Part 8: Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV |
EN 60071-2:1997 | Insulation co-ordination - Part 2: Application guide |
IEC 60507:2013 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
IEC TS 60815-1:2008 | Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles |
EN 62271-200:2012/AC:2015 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV (IEC 62271-200:2011) |
IEC TS 60815-3:2008 | Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 3: Polymer insulators for a.c. systems |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.