I.S. EN 50600-2-2:2014
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-2: POWER DISTRIBUTION
Hardcopy , PDF
21-06-2019
English
01-01-2014
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Conformance
5 Power supply and distribution within
data centres
6 Availability
7 Physical security
8 Energy efficiency enablement and
power distribution
Annex A (informative) - Example implementations of
power distribution
Bibliography
Defines requirements and recommendations for the following: a) power supplies to data centres; b) power distribution systems within data centres; c) facilities for both normal and emergency lighting; d) equipotential bonding and earthing; e) lightning protection; f) devices for the measurement of the power consumption characteristics at points along the power distribution system and their integration within management tools.
DocumentType |
Standard
|
Pages |
40
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
EN 50600-2-2:2014 | Identical |
EN 50160 : 2010 AMD 1 2015 | VOLTAGE CHARACTERISTICS OF ELECTRICITY SUPPLIED BY PUBLIC ELECTRICITY NETWORKS |
IEC 60050-131:2002 | International Electrotechnical Vocabulary (IEV) - Part 131: Circuit theory |
IEC 61000-2-4:2002 | Electromagnetic compatibility (EMC) - Part 2-4: Environment - Compatibility levels in industrial plants for low-frequency conducted disturbances |
EN 50600-2-1:2014 | Information technology - Data centre facilities and infrastructures - Part 2-1: Building construction |
EN 62305-4:2011/AC:2016 | PROTECTION AGAINST LIGHTNING - PART 4: ELECTRICAL AND ELECTRONIC SYSTEMS WITHIN STRUCTURES (IEC 62305-4:2010) |
EN 50174-1:2009/A2:2014 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 1: INSTALLATION SPECIFICATION AND QUALITY ASSURANCE |
EN 61000-2-4:2002/AC:2014 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-4: ENVIRONMENT - COMPATIBILITY LEVELS IN INDUSTRIAL PLANTS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES |
EN 60076-11:2004 | Power transformers - Part 11: Dry-type transformers |
EN 50174-3:2013/A1:2017 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS |
IEC 88528-11:2004 | Reciprocating internal combustion engine driven alternating current generating sets - Part 11: Rotary uninterruptible power systems - Performance requirements and test methods |
HD 60364-4-444:2010/AC:2012 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-444: PROTECTION FOR SAFETY - PROTECTION AGAINST VOLTAGE DISTURBANCES AND ELECTROMAGNETIC DISTURBANCES |
EN 50600-1:2012 | INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 1: GENERAL CONCEPTS |
EN 50174-2 : 2009 AMD 2 2014 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 2: INSTALLATION PLANNING AND PRACTICES INSIDE BUILDINGS |
IEC 60044-1:1996+AMD1:2000+AMD2:2002 CSV | Instrument transformers - Part 1: Current transformers |
IEC 60364-4-44:2007+AMD1:2015 CSV | Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances |
EN 50600-2-4:2015 | Information technology - Data centre facilities and infrastructures - Part 2-4: Telecommunications cabling infrastructure |
PREN 50600-2-5 : DRAFT 2012 | BS EN 50600-2-5 - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-5: SECURITY SYSTEMS |
PREN 50600-2-3 : DRAFT 2012 | DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-3: ENVIRONMENTAL CONTROL |
EN 60044-1:1999/A2:2003 | INSTRUMENT TRANSFORMERS - PART 1: CURRENT TRANSFORMERS |
IEC 62305-4:2010 | Protection against lightning - Part 4: Electrical and electronic systems within structures |
EN 50310:2016 | Telecommunications bonding networks for buildings and other structures |
EN 88528-11 : 2004 | RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN ALTERNATING CURRENT GENERATING SETS - PART 11: ROTARY UNINTERRUPTIBLE POWER SYSTEMS - PERFORMANCE REQUIREMENTS AND TEST METHODS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.