I.S. EN 50491-5-1:2010
Current
The latest, up-to-date edition.
GENERAL REQUIREMENTS FOR HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) AND BUILDING AUTOMATION AND CONTROL SYSTEMS (BACS) - PART 5-1: EMC REQUIREMENTS, CONDITIONS AND TEST SET-UP
Hardcopy , PDF
English
01-01-2010
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 General requirements
5 Performance criteria
6 Standard test conditions
Annex A (informative) - Additional information for fast
transients (burst) test set up
Annex B (informative) - Test set ups
Annex ZZ (informative) - Coverage of essential Requirements
of EC Directives
Bibliography
Arranges the minimum level of EMC performance for HBES/BACS products intended to be connected to an HBES/BACS system.
DevelopmentNote |
Partially supersedes 1998 edition of I.S. EN 50090-2-2. (07/2017)
|
DocumentType |
Standard
|
Pages |
19
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
SupersededBy |
Standards | Relationship |
EN 50491-5-1:2010 | Identical |
EN 61000-4-11:2004/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
EN 50491-3:2009 | General requirements for Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) - Part 3: Electrical safety requirements |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
EN 61000-3-3:2013 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION (IEC 61000-3-3:2013) |
IEC 62041:2017 | Transformers, power supplies, reactors and similar products - EMC requirements |
IEC 60669-2-1:2002+AMD1:2008+AMD2:2015 CSV | Switches for household and similar fixed electrical installations -Part 2-1: Particular requirements - Electronic switches |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
EN 62041:2010 | Safety of transformers, reactors, power supply units and combinations thereof - EMC requirements |
EN 55022:2010/AC:2011 | INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008) |
EN 61000-4-8:2010 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
EN 61000-3-2:2014 | Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase) |
EN 50428 : 2005 AMD 2 2009 | SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS - COLLATERAL STANDARD - SWITCHES AND RELATED ACCESSORIES FOR USE IN HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
EN 61000-4-6:2014/AC:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.