I.S. EN 50399:2011
Current
The latest, up-to-date edition.
COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - HEAT RELEASE AND SMOKE PRODUCTION MEASUREMENT ON CABLES DURING FLAME SPREAD TEST - TEST APPARATUS, PROCEDURES, RESULTS
Hardcopy , PDF
English
01-01-2011
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
National Foreword
European foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Test apparatus
5 Qualification of test apparatus
6 Test procedure
7 Determination of parameters derived from the test
8 Test report
Annex A (normative) - Calculation of heat release
Annex B (normative) - Smoke production
Annex C (informative) - Additional information on Reynolds
number in Figure 5
Annex D (normative) - Flow distribution inside the duct
Annex E (normative) - Commissioning calibrations
Annex F (informative) - Guidance for calibration procedures
for specific measuring equipment
Annex G (normative) - Calculation of HRR[av], SPR[av]
and FIGRA
Annex H (informative) - Guidance on the choice of test
Equipment
Annex I (informative) - Guidance on the file format for
data from the test
Annex J (normative) - Rounding of numbers
Bibliography
Describes the apparatus and methods of test for the assessment of vertical flame spread, heat release, smoke production and occurrence of flaming droplets/particles of vertically-mounted bunched wires or cables, electrical or optical, under defined conditions.
DocumentType |
Standard
|
Pages |
72
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
SupersededBy |
Standards | Relationship |
EN 50399 : 2011 AMD 1 2016 | Identical |
EN ISO 5167-2:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 2: Orifice plates (ISO 5167-2:2003) |
ISO 9705:1993 | Fire tests Full-scale room test for surface products |
89/106/EEC : 1988 | COUNCIL DIRECTIVE OF 21 DECEMBER 1988 ON THE APPROXIMATION OF LAWS, REGULATIONS AND ADMINISTRATIVE PROVISIONS OF THE MEMBER STATES RELATING TO CONSTRUCTION PRODUCTS |
ISO 13943:2017 | Fire safety — Vocabulary |
ISO 5167-4:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 4: Venturi tubes |
EN 13823:2010+A1:2014 | Reaction to fire tests for building products - Building products excluding floorings exposed to the thermal attack by a single burning item |
EN ISO 5167-4:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 4: Venturi tubes (ISO 5167-4:2003) |
ISO 5167-2:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 2: Orifice plates |
EN 60332-3-10:2009 | Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus |
EN 14390:2007 | Fire test - Large-scale room reference test for surface products |
EN 60584-1:2013 | Thermocouples - Part 1: EMF specifications and tolerances |
EN ISO 13943:2017 | Fire safety - Vocabulary (ISO 13943:2017) |
ISO 3966:2008 | Measurement of fluid flow in closed conduits Velocity area method using Pitot static tubes |
IEC 60584-1:2013 | Thermocouples - Part 1: EMF specifications and tolerances |
IEC 60332-3-10:2000+AMD1:2008 CSV | Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus |