I.S. EN 50377-13-3:2011
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
CONNECTOR SETS AND INTERCONNECT COMPONENTS TO BE USED IN OPTICAL FIBRE COMMUNICATION SYSTEMS - PRODUCT SPECIFICATIONS - PART 13-3: TYPE LX.5-APC DUPLEX TERMINATED ON IEC 60793-2-50 CATEGORY B1.1 AND B1.3 SINGLEMODE FIBRE, WITH FULL ZIRCONIA FERRULE CATEGORY U
Hardcopy , PDF
13-05-2021
English
01-01-2011
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
1 Scope
2 Normative references
3 Description
4 Variants
5 Dimensional requirements
6 Tests
7 Test report
8 Performance requirements
Annex A (informative) - Attenuation against reference
Annex B (normative) - Adaptor matched reference plug
details
Annex C (normative) - Sample size and product sourcing
requirements
Annex D (informative) - Zirconia ferrule response surface
Bibliography
Includes the initial, start of life dimensional, optical, mechanical and environmental performance requirements which a terminated and assembled singlemode resilient alignment sleeve LX.5 APC connector set (plug/adaptor/plug) should meet in order for it to be categorised as an EN standard product.
DocumentType |
Standard
|
Pages |
42
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Withdrawn
|
Standards | Relationship |
EN 50377-13-3:2011 | Identical |
IEC 61300-3-10:2006 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-10: Examinations and measurements - Gauge retention force |
ISO 8015:2011 | Geometrical product specifications (GPS) Fundamentals Concepts, principles and rules |
EN 61300-2-5:2011 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-5: Tests - Torsion |
EN 61754-23:2005 | Fibre optic connector interfaces - Part 23: Type LX.5 connector family |
EN 61300-2-18:2005 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-18: Tests - Dry heat - High temperature endurance |
IEC 61300-3-28:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-28: Examinations and measurements - Transient loss |
EN 61300-2-1:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal) |
EN 61300-3-4:2013 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-4: Examinations and measurements - Attenuation |
EN 60794-2:2017 | Optical fibre cables - Part 2: Indoor cables - Sectional specification |
IEC 61300-3-16:2003 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-16: Examinations and measurements - Endface radius of spherically polished ferrules |
EN 61300-2-17:2011 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-17: Tests - Cold |
EN 60793-2-50:2016 | Optical fibres - Part 2-50: Product specifications - Sectional specification for class B single-mode fibres |
EN 61300-2-2:2009/corrigendum:2009 | FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - BASIC TEST AND MEASUREMENT PROCEDURES - PART 2-2: TESTS - MATING DURABILITY |
IEC 61300-2-1:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal) |
IEC 61300-2-12:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-12: Tests - Impact |
EN 61300-2-6:2011 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-6: Tests - Tensile strength of coupling mechanism |
EN 61300-2-22:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22: Tests - Change of temperature |
EN 61300-2-44:2013 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-44: Tests - Flexing of the strain relief of fibre optic devices |
IEC 61300-2-17:2010 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-17: Tests - Cold |
IEC 61753-1:2007 | Fibre optic interconnecting devices and passive components performance standard - Part 1: General and guidance for performance standards |
EN 61753-1:2007 | Fibre optic interconnecting devices and passive components performance standard - Part 1: General and guidance for performance standards |
EN 61300-3-23:1998 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-23: Examination and measurements - Fibre position relative to ferrule endface |
IEC 61300-2-46:2006 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-46: Tests - Damp heat, cyclic |
IEC 61300-2-5:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-5: Tests - Torsion |
EN 61755-2-2 : 2006 | FIBRE OPTIC CONNECTOR OPTICAL INTERFACES - PART 2-2: OPTICAL INTERFACE STANDARD SINGLE MODE ANGLED PHYSICALLY CONTACTING FIBRES |
IEC 61300-3-34:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-34: Examinations and measurements - Attenuation of random mated connectors |
IEC 61300-3-23:1998 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-23: Examination and measurements - Fibre position relative to ferrule endface |
IEC 61300-2-26:2006 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-26: Tests - Salt mist |
EN 61300-3-16:2003 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-16: Examinations and measurements - Endface radius of spherically polished ferrules |
IEC 61300-2-18:2005 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-18: Tests - Dry heat - High temperature endurance |
IEC 61300-2-22:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22: Tests - Change of temperature |
EN 60794-2-50 : 2008 | OPTICAL FIBRE CABLES - PART 2-50: INDOOR CABLES - FAMILY SPECIFICATION FOR SIMPLEX AND DUPLEX CABLES FOR USE IN TERMINATED CABLE ASSEMBLIES |
IEC 61300-3-6:2008 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-6: Examinations and measurements - Return loss |
IEC 61300-3-15:2006 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-15: Examinations and measurements - Dome eccentricity of a convex polished ferrule endface |
EN 61300-3-6:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-6: Examinations and measurements - Return loss |
IEC 61300-3-35:2015 RLV | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-35: Examinations and measurements - Visual inspection of fibre optic connectors and fibre-stub transceivers |
IEC 61300-2-7:2013 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-7: Tests - Bending moment |
EN 61300-2-12:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-12: Tests - Impact |
IEC 61300-3-4:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-4: Examinations and measurements - Attenuation |
EN 61300-2-4:1997 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-4: Tests - Fibre/cable retention |
EN 61300-3-15:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-15: Examinations and measurements - Dome eccentricity of a convex polished ferrule endface |
EN 61755-1:2006/corrigendum:2006 | FIBRE OPTIC CONNECTOR OPTICAL INTERFACES - PART 1: OPTICAL INTERFACES FOR SINGLE MODE NON-DISPERSION SHIFTED FIBRES - GENERAL AND GUIDANCE |
IEC 61754-23:2005 | Fibre optic connector interfaces - Part 23: Type LX.5 connector family |
IEC 61300-2-42:2014 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-42: Tests - Static side load for strain relief |
EN 61300-3-35:2015 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-35: Examinations and measurements - Visual inspection of fibre optic connectors and fibre-stub transceivers |
EN 61300-3-28:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-28: Examinations and measurements - Transient loss |
IEC 60793-2-50:2015 | Optical fibres - Part 2-50: Product specifications - Sectional specification for class B single-mode fibres |
EN 61300-3-42:2008 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-42: Examinations and measurements - Attenuation of single mode alignment sleeves and or adaptors with resilient alignment sleeves |
IEC 61755-3-2:2006 | Fibre optic connector optical interfaces - Part 3-2: Optical interface, 2,5 mm and 1,25 mm diameter cylindrical full zirconia ferrules for 8 degrees angled-PC single mode fibres |
IEC 61300-2-44:2013 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-44: Tests - Flexing of the strain relief of fibre optic devices |
IEC 60794-2:2017 | Optical fibre cables - Part 2: Indoor cables - Sectional specification |
IEC 61755-2-2:2006 | Fibre optic connector optical interfaces - Part 2-2: Optical interface standard single mode angled physically contacting fibres |
IEC 61300-2-2:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-2: Tests - Mating durability |
IEC 61300-2-4:1995 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-4: Tests - Fibre/cable retention |
EN 61300-2-42:2014 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-42: Tests - Static side load for strain relief |
IEC 61754-15:2009 | Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 15: Type LSH connector family |
TS 100 671 : 1.3.1 | TRANSMISSION AND MULTIPLEXING (TM); PASSIVE OPTICAL COMPONENTS; OPTICAL FIBRE CONNECTORS FOR SINGLE MODE OPTICAL FIBRE COMMUNICATION SYSTEMS; COMMON REQUIREMENTS AND CONFORMANCE TESTING |
EN 61754-15:2009/AC:2014 | FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - FIBRE OPTIC CONNECTOR INTERFACES - PART 15: TYPE LSH CONNECTOR FAMILY (IEC 61754-15:2009) |
IEC 61300-2-6:2010 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-6: Tests - Tensile strength of coupling mechanism |
EN 61300-3-34:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-34: Examinations and measurements - Attenuation of random mated connectors |
EN 61300-2-26:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-26: Tests - Salt mist |
IEC 60794-2-50:2008 | Optical fibre cables - Part 2-50: Indoor cables - Family specification for simplex and duplex cables for use in terminated cable assemblies |
EN 61300-2-7:2013 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-7: Tests - Bending moment |
EN 61755-3-2:2009 | Fibre optic connector optical interfaces - Part 3-2: Optical interface, 2,5 mm and 1,25 mm diameter cylindrical full zirconia ferrules for 8 degrees angled-PC single mode fibres |
IEC 61755-1:2005 | Fibre optic connector optical interfaces - Part 1: Optical interfaces for single mode non-dispersion shifted fibres - General and guidance |
EN 61300-3-10:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-10: Examinations and measurements - Gauge retention force |
IEC 61300-3-42:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-42: Examinations and measurements - Attenuation of single mode alignment sleeves and or adaptors with resilient alignment sleeves |
EN 61300-2-46:2006 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-46: Tests - Damp heat cyclic |
IEC 61300-2-27:1995 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-27: Tests - Dust - Laminar flow |
EN 61300-2-27:1997 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-27: Tests - Dust - Laminar flow |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.