I.S. EN 15267-4:2017
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
AIR QUALITY - CERTIFICATION OF AUTOMATED MEASURING SYSTEMS - PART 4: PERFORMANCE CRITERIA AND TEST PROCEDURES FOR AUTOMATED MEASURING SYSTEMS FOR PERIODIC MEASUREMENTS OF EMISSIONS FROM STATIONARY SOURCES
Hardcopy , PDF
11-01-2024
English
01-01-2017
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
National Foreword
European foreword
0 Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 General requirements
6 Performance criteria common to all P-AMS for laboratory testing
7 Performance criteria common to all P-AMS for field testing
8 Performance criteria specific to measured components
9 General test requirements
10 Test procedures for laboratory tests
11 Requirements for the field test
12 Test procedures common to all P-AMS for field tests
13 Equivalence with the SRM
14 Measurement uncertainty
15 Test report
Annex A (normative) - Minimum requirements for a test bench
Annex B (normative) - Interferents
Annex C (normative) - Test of linearity
Annex D (normative) - Determination of the total uncertainty
Annex E (informative) - Elements of performance testing report
Annex F (informative) - European standard reference methods
Bibliography
Gives the general performance criteria and test procedures for portable automated measuring systems (P-AMS) used for periodic measurements of stationary source emissions.
DocumentType |
Standard
|
Pages |
64
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
EN 15267-4:2017 | Identical |
CEN/TS 15675:2007 | Air quality - Measurement of stationary source emissions - Application of EN ISO/IEC 17025:2005 to periodic measurements |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
EN 50160 : 2010 AMD 1 2015 | VOLTAGE CHARACTERISTICS OF ELECTRICITY SUPPLIED BY PUBLIC ELECTRICITY NETWORKS |
EN 15267-3:2007 | Air quality - Certification of automated measuring systems - Part 3: Performance criteria and test procedures for automated measuring systems for monitoring emissions from stationary sources |
EN 50379-3:2012 | Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances - Part 3: Performance requirements for apparatus used in non-statutory servicing of gas fired heating appliances |
EN 14791:2017 | Stationary source emissions - Determination of mass concentration of sulphur oxides - Standard reference method |
EN ISO/IEC 17043:2010 | Conformity assessment - General requirements for proficiency testing (ISO/IEC 17043:2010) |
EN 50379-2:2012 | Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances - Part 2: Performance requirements for apparatus used in statutory inspections and assessment |
ISO 14956:2002 | Air quality — Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty |
EN ISO 9169:2006 | Air quality - Definition and determination of performance characteristics of an automatic measuring system (ISO 9169:2006) |
2004/108/EC : 2004 | DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 15 DECEMBER 2004 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO ELECTROMAGNETIC COMPATIBILITY AND REPEALING DIRECTIVE 89/336/EC |
EN 15267-2:2009 | Air quality - Certification of automated measuring systems - Part 2: Initial assessment of the AMS manufacturer’s quality management system and post certification surveillance for the manufacturing process |
EN 14789:2017 | Stationary source emissions - Determination of volume concentration of oxygen - Standard reference method: Paramagnetism |
EN 15259:2007 | Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report |
EN 13284-1:2017 | Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual gravimetric method |
EN 14181:2014 | Stationary source emissions - Quality assurance of automated measuring systems |
EN 15058:2017 | Stationary source emissions - Determination of the mass concentration of carbon monoxide - Standard reference method: non-dispersive infrared spectrometry |
EN 12619:2013 | Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
ISO/IEC 17043:2010 | Conformity assessment — General requirements for proficiency testing |
EN 1911:2010 | Stationary source emissions - Determination of mass concentration of gaseous chlorides expressed as HCl - Standard reference method |
EN ISO 14956:2002 | Air quality - Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty (ISO 14956:2002) |
ISO 5725-2:1994 | Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
EN 14790:2017 | Stationary source emissions - Determination of the water vapour in ducts - Standard reference method |
EN 50379-1:2012 | Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances - Part 1: General requirements and test methods |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 14792:2017 | Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: chemiluminescence |
EN 15267-1:2009 | Air quality - Certification of automated measuring systems - Part 1: General principles |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
ISO 9169:2006 | Air quality Definition and determination of performance characteristics of an automatic measuring system |
EN 14793:2017 | Stationary source emissions - Demonstration of equivalence of an alternative method with a reference method |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.