I.S. EN 14884:2006
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
AIR QUALITY - STATIONARY SOURCE EMISSIONS - DETERMINATION OF TOTAL MERCURY: AUTOMATED MEASURING SYSTEMS
Hardcopy , PDF
11-07-2023
English
01-01-2006
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Principle
5 AMS performance criteria for QAL 1
6 AMS location
7 Calibration and validation of the AMS (QAL2)
7.1 General
7.2 Calibration procedure
7.2.1 Parallel measurements with SRM
7.2.2 Automatic recording of AMS output signals
7.3 Establishing the calibration function
8 Ongoing quality assurance during operation (QAL 3)
9 Annual surveillance test (AST)
Annex A (informative) Example of calculation of the
calibration function and of the variability
test
A.1 General
A.2 Data evaluation
A.2.1 General
A.2.2 Calculation of measured values of the
SRM at standard conditions
A.2.3 Calibration function
A.2.4 Calibrated values of AMS
A.2.5 Conversion of data to standard conditions
A.2.6 Valid calibration range
A.2.7 Test of variability
Bibliography
Describes the requirements on automated measuring systems (AMS) for monitoring of total mercury.
DocumentType |
Standard
|
Pages |
20
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
ONORM EN 14884 : 2006 | Identical |
NS EN 14884 : 1ED 2006 | Identical |
BS EN 14884:2005 | Identical |
NEN EN 14884 : 2006 | Identical |
EN 14884:2005 | Identical |
UNI EN 14884 : 2006 | Identical |
SN EN 14884 : 2006 | Identical |
UNE-EN 14884:2006 | Identical |
NF EN 14884 : 2006 | Identical |
NBN EN 14884 : 2006 | Identical |
DIN EN 14884:2006-03 | Identical |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
ISO 14956:2002 | Air quality — Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty |
EN 14181:2014 | Stationary source emissions - Quality assurance of automated measuring systems |
EN ISO 14956:2002 | Air quality - Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty (ISO 14956:2002) |
ENV 13005 : DRAFT 1999 | GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.