I.S. EN 1434-2:2015
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
HEAT METERS - PART 2: CONSTRUCTIONAL REQUIREMENTS
Hardcopy , PDF
03-02-2020
22-11-2015
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
European foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Temperature sensors
5 Flow sensors
6 Calculators
7 Complete meter
8 Interfaces between sub-assemblies
9 Marking and security seals
Annex A (informative) Examples of temperature sensors
Annex B (normative) Input and output test signals
Annex C (informative) Low voltage Power Supply for heat meters and their sub-assemblies
Annex ZA (informative) Relationship between this European Standard and the essential requirements of Directive2014/32/EU aimed to be covered
Bibliography
This European Standard specifies the constructional requirements for heat meters.
Committee |
TC 176
|
DocumentType |
Standard
|
Pages |
46
|
ProductNote |
The date of any NSAI previous adoption may not match the date of its original CEN/CENELEC document.
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
DIN EN 1434-2:2016-02 | Identical |
NEN EN 1434-2 : 2015 | Identical |
NBN EN 1434-2 : 2015 | Identical |
ONORM EN 1434-2 : 2016 | Identical |
UNI EN 1434-2 : 2007 | Identical |
NF EN 1434-2 : 2016 | Identical |
SN EN 1434-2 : 2016 | Identical |
NS EN 1434-2 : 1997 | Identical |
EN 1434-2:2015 | Identical |
BS EN 1434-2 : 2015 | Identical |
UNE-EN 1434-2:2016 | Identical |
EN 10088-3:2014 | Stainless steels - Part 3: Technical delivery conditions for semi-finished products, bars, rods, wire, sections and bright products of corrosion resisting steels for general purposes |
ISO 4903:1989 | Information technology Data communication 15-pole DTE/DCE interface connector and contact number assignments |
EN ISO 228-1:2003 | Pipe threads where pressure-tight joints are not made on the threads - Part 1: Dimensions, tolerances and designation (ISO 228-1:2000) |
EN 60947-5-6:2000 | Low-voltage switchgear and controlgear - Part 5-6: Control circuit devices and switching elements - DC interface for proximity sensors and switching amplifiers (NAMUR) |
EN 60751:2008 | INDUSTRIAL PLATINUM RESISTANCE THERMOMETERS AND PLATINUM TEMPERATURE SENSORS |
IEC 60751:2008 | Industrial platinum resistance thermometers and platinum temperature sensors |
ISO 286-2:2010 | Geometrical product specifications (GPS) ISO code system for tolerances on linear sizes Part 2: Tables of standard tolerance classes and limit deviations for holes and shafts |
EN 1434-1:2015 | Heat meters - Part 1: General requirements |
EN 1434-3:2015 | Heat meters - Part 3: Data exchange and interfaces |
EN 1092-2:1997 | Flanges and their joints - Circular flanges for pipes, valves, fittings and accessories, PN designated - Part 2: Cast iron flanges |
ISO 228-1:2000 | Pipe threads where pressure-tight joints are not made on the threads Part 1: Dimensions, tolerances and designation |
IEC 60947-5-6:1999 | Low-voltage switchgear and controlgear - Part 5-6: Control circuit devices and switching elements - DC interface for proximity sensors and switching amplifiers (NAMUR) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.