I.S. EN 116000-3:1998
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
GENERIC SPECIFICATION: ELECTROMECHANICAL ALL-OR-NOTHING RELAYS - PART 3: TEST AND MEASUREMENT PROCEDURES
Hardcopy , PDF
18-07-2006
English
27-11-1998
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
1 General
1.1 Scope
1.2 Normative references
2 Definitions
2.1 Types of relays
2.2 Types of relays, based upon environmental
protection
2.3 Functions of a relay
2.4 Types of contacts
2.5 Prefixes for the values applicable to relays
2.6 Energization values
2.7 Electrical properties of contacts
2.8 Categories of application of contacts
2.9 Mechanical properties of contacts
2.10 Terms relating to times
2.11 Coil transient suppression device
3 Test and measurement procedures
3.1 General
3.2 Alternative test methods
3.3 Precision of measurement
3.4 Requirements in Detail Specifications
3.5 Standard conditions for testing
3.6 Visual inspection and check of dimensions
3.7 Mechanical tests and weighing
3.8 Relay coil properties
3.9 Dielectric test
3.10 Impulse voltage test
3.11 Insulation resistance
3.12 Contact-circuit resistance (or voltage drop)
3.13 Functional tests
3.14 Timing tests
3.15 Climatic sequence
3.16 Damp heat, steady state
3.17 Thermal resistance
3.18 Heating
3.19 Rapid change of temperature
3.20 Enclosure
3.21 Internal moisture
3.22 Corrosive atmosphere
3.23 Mould growth
3.24 Robustness of terminals
3.25 Soldering
3.26 Shock
3.27 Bump
3.28 Vibration
3.29 Acceleration
3.30 Electrical endurance
3.31 Mechanical endurance
3.32 Thermal endurance
3.33 Limiting continuous current
3.34 Overload (contact circuit)
3.35 Load transfer
3.36 Electromagnetic compatibility
3.37 Magnetic interference
3.38 Crosstalk and insertion loss
3.39 Electrical contact noise
3.40 Thermoelectric e.m.f.
3.41 Capacitance
3.42 Contact sticking
3.43 Magnetic remanence
3.44 Acoustic noise
3.45 Continuity of protective earth connection
3.46 Fluid contamination
3.47 Resistance to cleaning solvents
3.48 Fire hazard
3.49 Free particle noise test
3.50 Contact dynamic dielectric test
3.51 Temperature rise at rated load
3.52 Ozone test
3.53 Explosion proof
3.54 Rupture
3.55 Time current characteristic
3.56 Mechanical interlock
3.57 Mixed load
3.58 Insertion and withdrawal forces
3.59 Immersion
3.60 Monitoring of contacts
Annex A (informative) Free particle noise test
Forms the basis for qualification approval within the CECC quality assessment system in accordance with CECC 00114.
DocumentType |
Standard
|
Pages |
68
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Withdrawn
|
Standards | Relationship |
SN EN 116000-3 : 1996 | Identical |
BS EN 116000-3:1996 | Identical |
NEN EN 116000-3 : 1996 | Identical |
DIN EN 116000-3:1996-10 | Identical |
EN 116000-3 : 1996 | Identical |
HD 323.2.11 : 200S1 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST KA: SALT MIST |
HD 323.2.20 : 200S3 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST T - SOLDERING |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
HD 323.2.13 : 200S1 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST M: LOW AIR PRESSURE |
IEC 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
CECC 00802 : 1994 | GUIDANCE DOCUMENT: CECC STANDARD METHOD FOR THE SPECIFICATION OF SURFACE MOUNTING (SMDs) OF ASSESSED QUALITY |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 60068-2-21:2006 | Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices |
IEC 60068-2-13:1983 | Basic environmental testing procedures - Part 2-13: Tests - Test M: Low air pressure |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
IEC 60068-2-11:1981 | Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist |
HD 323.2.14 : 200S2 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST N: OF TEMPERATURE |
EN 60068-2-7:1993 | Environmental testing - Part 2: Tests - Test Ga: Acceleration, steady state |
HD 588.1 : S1 AMD 1 | HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS |
HD 323.2.34 : 200S1 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST Fd: RANDOM VIBRATION WIDE BAND - GENERAL REQUIREMENTS |
IEC 60027-1:1992 | Letters symbols to be used in electrical technology - Part 1: General |
CECC 00114 : 93 AMD 1 | QUALITY ASSESSMENT PROCEDURES - APPROVAL OF MANUFACTURERS AND OTHER ORGANIZATIONS |
HD 323.2.30 : 200S3 | BASIC ENVIRONMENTAL TESTING PROCEDURES - PART 2: TESTS - TEST DB AND GUIDANCE: DAMP HEAT, CYCLIC (12 + 12-HOUR CYCLE) |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
HD 323.2.3 : 200S2 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST CA - DAMP HEAT, STEADY STATE |
IEC 60068-2-3:1969 | Basic environmental testing procedures - Part 2-3: Tests - Test Ca: Damp heat, steady state |
EN 60068-2-17:1994 | Environmental testing - Part 2: Tests - Test Q: Sealing |
IEC 60050-446:1983 | International Electrotechnical Vocabulary (IEV) - Part 446: Electrical relays |
IEC 60068-2-17:1994 | Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing |
IEC 60068-2-10:2005 | Environmental testing - Part 2-10: Tests - Test J and guidance: Mould growth |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
HD 323.2.10 : 200S3 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST J AND GUIDANCE: MOULD GROWTH |
EN 60068-2-29:1993 | Environmental testing - Part 2: Tests - Test Eb and guidance: Bump |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
IEC 60068-2-29:1987 | Environmental testing. Part 2: Tests. Test Eb and guidance: Bump |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
HD 323.2.21 : 200S3 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST U: ROBUSTNESS OF TERMINATIONS AND INTEGRAL MOUNTING DEVICES |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.