HD 627 S1:1996/A2:2005
Current
The latest, up-to-date edition.
MULTICORE AND MULTIPAIR CABLES FOR INSTALLATION ABOVE AND BELOW GROUND
28-11-2005
PART 1 General Requirements
PART 2 Special test methods
PART 3 Multicore and multipair cables for use underground
3-A1: Multicore cable with copper conductors, single wire
armoured and PVC sheathed
3-A2: Multipair cable with copper conductors, single wire
armoured and PVC sheathed
3-E: 450/750 V multicore cable with polyethylene insulation
and sheath
3-F1: 300 V armoured XLPE insulated and PVC sheathed,
screened instrumentation cables
3-F2: 250 V armoured PVC insulated and PVC sheathed single
and multipair screened signalling cables
3-F3: 1kV armoured multicore XLPE insulated and PVC
sheathed cables
PART 4 Multicore and multipair halogenated cables complying with HD
405.1
4-B1: 500 V multiquad cables with and without a metallic
covering
4-B2: 750 V multicore cables with and without a metallic
covering
4-C1: 300/500 V Cables with solid or stranded conductors and
with or without a common screen
4-C2: Screened cables with stranded conductors and rated
voltage 150/250 V
4-D1: 450/750 V multicore PVC insulated and sheathed cables
4-D2: 450/750 V multicore PVC insulated and sheathed cables
with concentric conductor
4-E1: 450/750 V multicore cable with a metallic covering
4-E2: Multipair cables with a metallic covering
4-E3: 450/750 V multicore cable with a metallic covering
4-F: 300 V armoured and unarmoured XLPE insulated and PVC
sheathed, screened instrumentation cables
4-H1: 0.6/1kV PVC insulated multicore cables with and without
concentric conductor
4-H2: 0.6/1kV XLPE insulated multicore cables with or without
concentric conductor
4-J1: PVC insulated and sheathed multicore and multipair
cables
4-J2: 0.6/1kV multicore cables with a metallic screen
4-N: Multicore cables with PVC-insulation with and without
concentric conductor or screen or armouring for rated
voltages 0,6/1 kV
PART 5 Multicore and Multipair halogenated cables complying with HD
405.3 or similar
5-A1: Multicore cables with copper conductors, single wire
armoured and PVC sheathed
5-A2: Multipair cables with copper conductors, single wire and
double steel tape armoured and PVC sheathed
5-F1: 1kV XLPE insulated and PVC sheathed multicore cables
5-F2: 250 V PVC insulated and PVC sheathed multicore,
single and multipair signalling cables
5-F3: 500 V screened and unscreened PVC insulated and PVC
sheathed multicore control cables
5-F4: 300 V armoured and unarmoured XLPE insulated and
PVC sheathed, screened instrumentation cables
5-G1: Cables in pairs, triples and quads with copper
conductors, PVC insulated and sheathed and metallic
screen
5-G2: Cables in pairs, triples and quads with copper
conductors, EPR insulation, CSP sheaths and metallic
screen
5-M: PVC insulated and sheathed multicore cables and PVC or
Polyethylene insulated and PVC sheathed multipair cables
PART 6 Multicore and multipair halogen-free cables complying with HD
405.1
6-E: 450/750 V multicore cables with common screen
PART 7: Multicore and multipair halogen-free cables complying with
HD 405.3 or similar
7-A1: Multicore cables with copper conductors, single wire
armoured and unarmoured with non-halogenated
sheath
7-A2: Multipair cables with copper conductors single wire and
double steel tape armoured with non-halogenated
sheath
7-B1: 500 V multiquad cables with a metallic covering
7-B2: 750 V multicore cables with a metallic covering
7-D1: 450/750 V multicore cables without screen
7-D2: 450/750 V multicore cables with concentric conductor
7-F1: 1kV XLPE insulated and non-halogenated sheathed
multicore cables
7-F2: 300 V armoured and unarmoured XLPE insulated and
non-halogenated sheathed and screened
instrumentation cables
7-G: Cables in pairs, triples and quads with copper
conductors, metallic screen and having halogen free
all-non-metallic components
7-H: 0.6/1kV multicore cables with and without a concentric
conductor
7-K: 150 V multicore and multipair cables with and without a
metallic covering
7-L1: Cables in pairs and triples and multicore cables with
circular copper conductors and metallic covering
7-L2: Multipair and multicore cables with circular copper
conductors for plug-in connections
7-M: EPR or XLPE insulated and ZH sheathed multicore cables
and polyethylene insulated and ZH sheathed multipair
cables
7-N: Halogen free, multicore cables with and without
concentric conductor or screen for rated voltages
0,6/1 kV
Applies to multicore and multipair rigid and flexible conductor cables for fixed installations having a rated voltage up to 1 kV and operating at a voltage above 80 V r.m.s.
Committee |
TC 20
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
UNE-HD 627-7M:1997 | Identical |
DIN VDE 0276-627 : 2006 | Identical |
CEI 20-59 V2 : 2006 | Identical |
PN HD 627 : 2002 AMD 2 2006 | Identical |
CEI 20-59 : 1999 | Identical |
CEI 20-59 V1 : 2006 | Identical |
VDE 0276-627 : 2006 | Identical |
NBN HD 627 : 1997 AMD 2 2007 | Identical |
SN HD 627 : S1 AMD 1 2000 | Identical |
NEN HD 627 : 1998 AMD 2 2005 | Identical |
I.S. HD 627:2003 | Identical |
PNE-HD 627S1:1996/prA2 | Identical |
BS 7870-8.4:2003 | Identical |
DIN VDE 0276-627 : 2006 | Corresponds |
BS 7870-8.2:2003 | Identical |
BS 7870-8.1:2003 | Identical |
BS 7870-3.50:2005 | LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated, copper wire waveform or helical concentric cables with solid aluminium conductors, having low emission of smoke and corrosive gases when affected by fire. (Implementation of HD 603) |
BS 7870-6.3:1999 | LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for 0.6/1 kV and 1.9/3.3 kV power cables with special fire performance for use in power stations - Cables with thermosetting insulation and non-halogenated sheath |
11/30214073 DC : 0 | BS 7870-4.10 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV AND 33 KV - SECTION 4.10: SINGLE-CORE 11 KV AND 33 KV CABLES |
BS EN 50363-0:2011 | Insulating, sheathing and covering materials for low-voltage energy cables General introduction |
11/30214059 DC : 0 | BS 7870-3.11 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 3: SPECIFICATION FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0.6/1 KV - SECTION 3.11: XLPE INSULATED COMBINED NEUTRAL AND EARTH COPPER WIRE CONCENTRIC CABLES WITH COPPER OR ALUMINIUM CONDUCTORS |
11/30214055 DC : 0 | BS 7870-1 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 1: GENERAL |
BS EN 45510-2-8:2004 | Guide for procurement of power station equipment Electrical equipment - Power cables |
11/30214071 DC : 0 | BS 7870-3.50 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 3: SPECIFICATION FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0.6/1 KV - SECTION 3.50: XLPE INSULATED, COPPER WIRE WAVEFORM OR HELICAL CONCENTRIC CABLES WITH SOLID ALUMINIUM CONDUCTORS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE |
BS 7870-3.12:2001 | LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV - XLPE insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors, having low emission of smoke and corrosive gases when affected by fire |
BS 7870-8.5:2003 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire armoured and unarmoured multicore cables with copper conductors and non-halogenated sheath - Section 8.5 Single wire armoured and unarmoured multicore cables with copper conductors and non-halogenated sheath |
BS 7870-6.2:1999 | LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for 0.6/1 kV and 1.9/3.3 kV power cables with special fire performance for use in power stations - XLPE or HEPR insulated and PVC sheathed cables |
BS 7870-1:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities General |
11/30214068 DC : 0 | BS 7870-3.40 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 3: SPECIFICATION FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0.6/1 KV - SECTION 3.40: XLPE INSULATED, COPPER WIRE WAVEFORM CONCENTRIC CABLES WITH SOLID ALUMINIUM CONDUCTORS |
BS 7870-4.10(2011) : 2011 | LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION OF RATED VOLTAGES OF 11 KV TO 33 KV - SECTION 4.10: SINGLE-CORE 11 KV TO 33 KV CABLES (IMPLEMENTATION OF HD 620) |
BS EN 50363-9-1:2005 | Insulating, sheathing and covering materials for low-voltage energy cables Miscellaneous insulating compounds. Cross-linked polyvinyl chloride (XLPVC) |
BS 7870-3.21:2001 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV XLPE insulated split concentric cables with copper or aluminium conductors |
CEI UNI EN 45510-2-8 : 2006 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-8: ELECTRICAL EQUIPMENT - POWER CABLES |
I.S. EN 50363-0:2011 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW-VOLTAGE ENERGY CABLES - PART 0: GENERAL INTRODUCTION |
EN 50363-10-1:2005 | Insulating, sheathing and covering materials for low voltage energy cables - Part 10-1: Miscellaneous sheathing compounds - Cross-linked polyvinyl chloride (XLPVC) |
BS 7870-4.11(2011) : 2011 | LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV AND 33 KV - SECTION 4.11: SINGLE-CORE 33 KV LEAD SHEATHED CABLES (IMPLEMENTATION OF HD 620) |
EN 45510-2-8 : 2004 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-8: ELECTRICAL EQUIPMENT - POWER CABLES |
EN 50363-9-1:2005 | Insulating, sheathing and covering materials for low voltage energy cables - Part 9-1: Miscellaneous insulating compounds - Cross-linked polyvinyl chloride (XLPVC) |
BS 7870-4.20(2011) : 2011 | LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV TO 33 KV - SECTION 4.20: THREE-CORE 11 KV CABLES (IMPLEMENTATION OF HD 620) |
BS 7870-5:1999 | LV and MV polymeric insulated cables for use by distribution and generation utilities Polymeric insulated aerial bundled conductors (ABC) of rated voltage 0.6/1 kV for overhead distribution |
11/30214061 DC : 0 | BS 7870-3.12 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 3: SPECIFICATION FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0.6/1 KV - SECTION 3.12: XLPE INSULATED COMBINED NEUTRAL AND EARTH COPPER WIRE CONCENTRIC CABLES WITH COPPER OR ALUMINIUM CONDUCTORS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE |
11/30219798 DC : 0 | BS 7870-5 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 5: POLYMERIC INSULATED AERIAL BUNDLED CONDUCTORS (ABC) OF RATED VOLTAGE 0.6/1 KV FOR OVERHEAD DISTRIBUTION |
I.S. EN 45510-2-9:2008 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-9: ELECTRICAL EQUIPMENT - CABLING SYSTEMS |
BS 7870-8.4:2003 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire or double steel tape armoured and PVC sheathed multipair cable with copper conductors, having reduced fire propagation performance - Section 8.4 Single wire or double steel tape armoured and PVC sheathed multipair cable with copper conductors, having reduced fire propagation performance |
I.S. HD 605:2008 | ELECTRIC CABLES - ADDITIONAL TEST METHODS |
HD 605 S2:2008/corrigendum:2010 | ELECTRIC CABLES - ADDITIONAL TEST METHODS |
BS 7870-3.11:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors |
BS 7870-3.12:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors, having low emission of smoke and corrosive gases when affected by fire |
BS 7870-3.11:2001 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV XLPE insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors |
BS 7870-3.21:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated split concentric cables with copper or aluminium conductors |
BS 7870-5:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities Polymeric insulated aerial bundled conductors (ABC) of rated voltage 0.6/1 kV for overhead distribution |
BS 7870-3.40:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated, copper wire waveform concentric cables with solid aluminium conductors |
BS 7870-3.50:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated, copper wire waveform or helical concentric cables with solid aluminium conductors, having low emission of smoke and corrosive gases when affected by fire |
05/30126924 DC : DRAFT MAY 2005 | BS 7870-3.50 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 3: SPECIFICATION FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0.6/1 KV - SECTION 3.50: XLPE INSULATED, COPPER WIRE WAVEFORM OR HELICAL CONCENTRIC CABLES WITH SOLID ALUMINIUM CONDUCTORS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE |
BS 7870-3.40:2001 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV XLPE insulated, copper wire waveform concentric cables with solid aluminium conductors |
BS 7870-7.1:2003 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for power cables having rated voltages of 3.8/6.6 kV and 6.35/11 kV with special fire performance for use in power stations Single core and 3-core cables with halogenated materials and with aluminium or steel wire armouring |
11/30214077 DC : 0 | BS 7870-4.20 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV AND 33 KV - SECTION 4.20: THREE-CORE 11 KV CABLES |
11/30214065 DC : 0 | BS 7870-3.22 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 3: SPECIFICATION FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0.6/1 KV - SECTION 3.22: XLPE INSULATED SPLIT CONCENTRIC CABLES WITH COPPER OR ALUMINIUM CONDUCTORS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE |
BS 7870-8.6:2003 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire or double steel tape armoured and non-halogenated sheathed multipair cable with copper conductors - Section 8.6 Single wire or double steel tape armoured and non-halogenated sheathed multipair cable with copper conductors |
BS 7870-2:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities Methods of test |
EN 45510-2-9:2008 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-9: ELECTRICAL EQUIPMENT - CABLING SYSTEMS |
EN 45510-2-8:2004 | Guide for procurement of power station equipment - Part 2-8: Electrical equipment - Power cables |
BS 7870-8.1:2003 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire armoured and PVC sheathed multicore cable with copper conductors - Section 8.1 Single wire armoured and PVC sheathed multicore cable with copper conductors |
11/30215743 DC : 0 | BS 7870-3.21 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 3: SPECIFICATION FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0.6/1 KV - SECTION 3.21: XLPE INSULATED SPLIT CONCENTRIC CABLES WITH COPPER OR ALUMINIUM CONDUCTORS |
BS 7870-6.1:1999 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for 0.6/1 kV and 1.9/3.3 kV power cables with special fire performance for use in power stations PVC insulated and PVC sheathed cables |
BS 7870-3.20:2001 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV PVC insulated split concentric cables with copper or aluminium conductors |
BS EN 50363-10-1:2005 | Insulating, sheathing and covering materials for low-voltage energy cables Miscellaneous sheathing compounds. Cross-linked polyvinyl chloride (XLPVC) |
I.S. EN 50363-9-1:2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 9-1: MISCELLANEOUS INSULATING COMPOUNDS - CROSS-LINKED POLYVINYL CHLORIDE (XLPVC) |
EN 45510-2-9 : 2008 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-9: ELECTRICAL EQUIPMENT - CABLING SYSTEMS |
BS 7870-8.2:2003 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire armoured and PVC sheathed multipair cable with copper conductors - Section 8.2 Single wire armoured and PVC sheathed multipair cable with copper conductors |
11/30214075 DC : 0 | BS 7870-4.11 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV AND 33 KV - SECTION 4.11: SINGLE-CORE 33 KV LEAD SHEATHED CABLES |
I.S. EN 45510-2-8:2004 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-8: ELECTRICAL EQUIPMENT - POWER CABLES |
BS 7870-7.2:2003 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for power cables having rated voltages of 3.8/6.6 kV and 6.35/11 kV with special fire performance for use in power stations Single-core and 3-core cables with halogen-free materials and with aluminium or steel wire armouring |
BS 7870-8.3:2003 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire armoured and PVC sheathed multicore cable with copper conductors, having reduced fire propagation performance - Section 8.3 Single wire armoured and PVC sheathed multicore cable with copper conductors, having reduced fire propagation performance |
BS 7870-3.22:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated split concentric cables with copper or aluminium conductors, having low emission of smoke and corrosive gases when affected by fire |
BS 7870-3.10:2001 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV PVC insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors |
UNI CEI EN 45510-2-8 : 2011 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-8: ELECTRICAL EQUIPMENT - POWER CABLES |
UNE-EN 50363-0:2011 | Insulating, sheathing and covering materials for low-voltage energy cables -- Part 0: General introduction |
BS EN 45510-2-9:2008 | Guide for procurement of power station equipment Electrical equipment. Cabling systems |
EN 50363-0:2011 | Insulating, sheathing and covering materials for low-voltage energy cables - Part 0: General introduction |
EN 50267-2-1:1998 | Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-1: Procedures - Determination of the amount of halogen acid gas |
IEC 60502:1994 | Extruded solid dielectric insulated power cables for rated voltages from 1 kV up to 30 kV |
IEC 60502-1:2004+AMD1:2009 CSV | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV(<em>U</em><sub>m</sub> = 36 kV) - Part 1: Cables for rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV) |
HD 605 S2:2008/corrigendum:2010 | ELECTRIC CABLES - ADDITIONAL TEST METHODS |
IEC 60754-1:2011 | Test on gases evolved during combustion of materials from cables - Part 1: Determination of the halogen acid gas content |
EN 60228:2005 COR 2005 | CONDUCTORS OF INSULATED CABLES |
EN 60332-1-2:2004/A11:2016 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004/A1:2015) |
HD 383 : S2 AMD 2 | CONDUCTORS OF INSULATED CABLES - GUIDE TO THE DIMENSIONAL LIMITS OF CIRCULAR CONDUCTORS |
IEC 60183:2015 | Guidance for the selection of high-voltage A.C. cable systems |
HD 186 : S2 AMD 1 | MARKING BY INSCRIPTION FOR THE IDENTIFICATION OF CORES OF ELECTRIC CABLES HAVING MORE THAN 5 CORES |
HD 602 : 200S1 | TEST ON GASES EVOLVED DURING COMBUSTION OF ELECTRIC CABLES - DETERMINATION OF DEGREE OF ACIDITY OF GASES EVOLVED DURING THE COMBUSTION OF MATERIALS TAKEN FROM ELECTRIC CABLES BY MEASURING PH CONDUCTIVITY |
EN 50334:2001 | Marking by inscription for the identification of cores of electric cables |
EN 50267-2-2:1998 | Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-2: Procedures - Determination of degree of acidity of gases for materials by measuring pH and conductivity |
EN 50265-2-1:1998 | Common test methods for cables under fire conditions - Test for resistance to vertical flame propagation for a single insulated conductor or cable - Part 2-1: Procedures - 1 kW pre-mixed flame |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.