1. General
    1.1 Scope
    1.2 Applicable tests
    1.3 Classification of tests according to the
         frequency with which they are carried out
    1.4 Sampling
    1.5 Pre-conditioning
    1.6 Test temperature
    1.7 Test voltage
    1.8 Checking of the durability of colours and
         markings
    1.9 Measurement of insulation thickness
    1.10 Measurement of sheath thickness
    1.11 Measurement of overall dimensions and ovality
    1.12 Solderability tests for untinned conductors
2. Electrical tests
    2.1 Electrical resistance of conductors
    2.2 Voltage test on completed cable
    2.3 Voltage test on cores
    2.4 Insulation resistance
    2.5 Long term resistance of insulation to direct
         current
    2.6 Test to check the absence of faults on
         insulation
    2.7 Surface resistance of sheath
3. Tests of mechanical strength of completed flexible
    cables
    3.1 Flexing test
    3.2 Static flexibility test
    3.3 Wear resistance test
    3.4 Three pulley flexing test
    3.5 Kink test
4. (Spare)
5. Test for resistance to hot particles
6. (Spare)
7. Ozone resistance test
    7.1 General
    7.2 Methods of test
    7.3 Method B
8. Test for resistance to heat of textile braid
Annex A Normative references (Normative)
Annex B Procedure for checking the efficacy of the
         method of spark testing (Normative)
Annex C Measurement of sheath thickness for flat cords
         (Normative)
Annex D Calculation of minimum insulation resistance
         (Informative)
Annex E Bibliography (Informative)

Specifies rigid and flexible cables with insulation and sheath, if any, based on vulcanised rubber, of rated voltages U[0]/U up to and including 450/750 V used in power installations of nominal voltage not exceeding 450/750 V a.c.

Committee
TC 20
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy
Supersedes

BS EN 50090-5-2:2004 Home and building electronic systems (HBES) Media and media dependent layers - Network based on HBES Class 1, Twisted Pair
BS EN 50395 : 2005 ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES
VDE 0472-514 : 1985 TESTING OF CABLES, WIRES AND FLEXIBLE CORDS; FAILURE ON INSULATION
DIN 57472-402 : 1984 TESTING OF INSULATED CABLES, WIRES AND FLEXIBLE CORDS; WALL THICKNESS AND THICKNESS OF ARMOURING
BS EN 61851-21:2002 Electric vehicle conductive charging system Electric vehicle requirements for conductive connection to an a.c./d.c. supply
I.S. EN 50090-5-2:2004 HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) - PART 5-2: MEDIA AND MEDIA DEPENDENT LAYERS - NETWORK BASED ON HBES CLASS 1, TWISTED PAIR
EN 50090-5-2:2004 Home and Building Electronic Systems (HBES) - Part 5-2: Media and media dependent layers - Network based on HBES Class 1, Twisted Pair
BS 6007:1991 Specification for rubber-insulated cables for electric power and lighting
97/703042 DC : DRAFT FEB 1997 PREN 50275-1 - CONDUCTIVE CHARGING FOR ELECTRIC VEHICLES - PART 1: GENERAL CONSIDERATIONS
EN 61851-21:2002 Electric vehicle conductive charging system - Part 21: Electric vehicle requirements for conductive connection to an a.c/d.c. supply
DIN VDE 0472-503 : 1985 TESTING OF CABLES, WIRES AND FLEXIBLE CORDS; SURFACE INSULATION RESISTANCE OF SHEATH
03/313661 DC : DRAFT SEP 2003 EN 50395 - ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES
EN 50395 : 2005 AMD 1 2011 ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES

EN 50268-1:1999 Common test methods for cables under fire conditions - Measurement of smoke density of cables burning under defined conditions - Part 1: Apparatus
EN 50266-2-1 : 2001 COR 2002 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY- MOUNTED BUNCHED WIRES OR CABLES - PART 2-1: PROCEDURES - CATEGORY A F/R
EN 50266-2-4 : 2001 COR 2002 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY- MOUNTED BUNCHED WIRES OR CABLES - PART 2-4: PROCEDURES - CATEGORY C
EN 60719:1993 Calculation of the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V
EN 50267-2-1:1998 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-1: Procedures - Determination of the amount of halogen acid gas
EN 50266-2-2 : 2001 COR 2002 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY- MOUNTED BUNCHED WIRES OR CABLES - PART 2-2: PROCEDURES - CATEGORY A
EN 50266-1:2001 Common test methods for cables under fire conditions - Test for vertical flame spread of vertically-mounted bunched wires or cables - Part 1: Apparatus
EN 50267-1:1998 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 1: Apparatus
HD 429 : 200S1 METHODS OF TEST FOR VOLUME RESISTIVITY AND SURFACE RESISTIVITY OF SOLID ELECTRICAL INSULATING MATERIALS
ISO 1302:2002 Geometrical Product Specifications (GPS) Indication of surface texture in technical product documentation
EN 50266-2-3 : 2001 COR 2002 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY- MOUNTED BUNCHED WIRES OR CABLES - PART 2-3: PROCEDURES - CATEGORY B
EN 50268-2:1999 Common test methods for cables under fire conditions - Measurement of smoke density of cables burning under defined conditions - Part 2: Procedure
EN 50265-2-2:1998 Common test methods for cables under fire conditions - Test for resistance to vertical flame propagation for a single insulated conductor or cable - Part 2-2: Procedures - Diffusion flame
EN 50267-2-3:1998 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-3: Procedures - Determination of degree of acidity of gases for cables by determination of the weighted average of pH and conductivity
EN 50266-2-5 : 2001 COR 2002 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY- MOUNTED BUNCHED WIRES OR CABLES - PART 2-5: PROCEDURES - SMALL CABLES - CATEGORY D
EN 50267-2-2:1998 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-2: Procedures - Determination of degree of acidity of gases for materials by measuring pH and conductivity
EN 60695-2-2:1994/A1:1995 FIRE HAZARD TESTING - TEST METHODS - NEEDLE-FLAME TEST
EN 50265-1:1998 Common test methods for cables under fire conditions - Test for resistance to vertical flame propagation for a single insulated conductor or cable - Part 1: Apparatus
EN 50265-2-1:1998 Common test methods for cables under fire conditions - Test for resistance to vertical flame propagation for a single insulated conductor or cable - Part 2-1: Procedures - 1 kW pre-mixed flame

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.