EN ISO 52016-1:2017
Current
The latest, up-to-date edition.
Energy performance of buildings - Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads - Part 1: Calculation procedures (ISO 52016-1:2017)
19-07-2017
European foreword
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols, subscripts and abbreviations
5 Description of the methods
6 Calculation method
7 Quality control
8 Compliance check
Annex A (normative) - Input and method selection data
sheet - Template
Annex B (informative) - Input and method selection data
sheet - Default choices
Annex C (normative) - Regional references in line with
ISO Global Relevance Policy
Annex D (normative) - Multi-zone calculation with thermal
coupling between zones
Annex E (normative) - Heat transfer and solar heat gains
of windows and special elements
Annex F (normative) - Calculation of solar shading
reduction factors
Annex G (normative) - Dynamic transparent building elements
Bibliography
ISO 52016-1:2017 specifies calculation methods for the assessment of:a) the (sensible) energy need for heating and cooling, based on hourly or monthly calculations;b) the latent energy need for (de-)humidification, based on hourly or monthly calculations;c) the internal temperature, based on hourly calculations;d) the sensible heating and cooling load, based on hourly calculations;e) the moisture and latent heat load for (de-)humidification, based on hourly calculations;f) the design sensible heating or cooling load and design latent heat load using an hourly calculation interval;g) the conditions of the supply air to provide the necessary humidification and dehumidification.The calculation methods can be used for residential or non-residential buildings, or a part of it, referred to as "the building" or the "assessed object".ISO 52016-1:2017 also contains specifications for the assessment of thermal zones in the building or in the part of a building. The calculations are performed per thermal zone. In the calculations, the thermal zones can be assumed to be thermally coupled or not.The calculation methods have been developed for the calculation of the basic energy loads and needs, without interaction with specific technical building systems, and for the calculation of the system specific energy loads and needs, including the interaction with specific systems. The hourly calculation procedures can also be used as basis for calculations with more extensive system control options.ISO 52016-1:2017 is applicable to buildings at the design stage, to new buildings after construction and to existing buildings in the use phase.NOTE Table 1 in the Introduction shows the relative position of ISO 52016-1:2017 within the set of EPB standards in the context of the modular structure as set out in ISO 52000-1.
Committee |
CEN/TC 89
|
DevelopmentNote |
Supersedes EN ISO 13792, EN ISO 13791, EN ISO 13790, EN 15265 and EN 15255. (07/2017)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Supersedes |
Standards | Relationship |
UNI EN ISO 52016-1 : 2018 | Identical |
ONORM EN ISO 52016-1 : 2018 | Identical |
UNE-EN ISO 52016-1:2017 | Identical |
I.S. EN ISO 52016-1:2017 | Identical |
DIN EN ISO 52016-1:2018-04 | Identical |
DIN EN ISO 52016-1 E : 2018 | Identical |
NF EN ISO 52016-1 : 2017 | Identical |
BS EN ISO 52016-1:2017 | Identical |
NS EN ISO 52016-1 : 2017 | Identical |
PN EN ISO 52016-1 : 2017 | Identical |
ISO 52016-1:2017 | Identical |
DIN EN ISO 52016-1:2015-03 (Draft) | Identical |
NEN EN ISO 52016-1 : 2017 | Identical |
SN EN ISO 52016-1 : 2017 | Identical |
SS-EN ISO 52016-1:2017 | Identical |
PNE-EN ISO 52016-1 | Identical |
15/30325699 DC : 0 | BS EN ISO 52000-1 - ENERGY PERFORMANCE OF BUILDINGS - OVERARCHING EPB ASSESSMENT - PART 1: GENERAL FRAMEWORK AND PROCEDURES |
DIN EN 16947-1:2016-01 (Draft) | ENERGY PERFORMANCE OF BUILDINGS - BUILDING MANAGEMENT SYSTEM - PART 1: MODULE M10-12 |
I.S. EN 16798-15:2017 | ENERGY PERFORMANCE OF BUILDINGS - VENTILATION FOR BUILDINGS - PART 15: CALCULATION OF COOLING SYSTEMS (MODULE M4-7) - STORAGE |
I.S. EN 16798-5-1:2017 | ENERGY PERFORMANCE OF BUILDINGS - VENTILATION FOR BUILDINGS - PART 5-1: CALCULATION METHODS FOR ENERGY REQUIREMENTS OF VENTILATION AND AIR CONDITIONING SYSTEMS (MODULES M5-6, M5-8, M6-5, M6-8, M7-5, M7-8) - METHOD 1: DISTRIBUTION AND GENERATION |
I.S. EN 16947-1:2017 | ENERGY PERFORMANCE OF BUILDINGS - BUILDING MANAGEMENT SYSTEM - PART 1: MODULE M10-12 |
CEI UNI EN 16247-2:2022 | Energy audits Part 2: Buildings<br> |
BS EN 15232-1:2017 | Energy Performance of Buildings Impact of Building Automation, Controls and Building Management. Modules M10-4,5,6,7,8,9,10 |
I.S. EN 16798-5-2:2017 | ENERGY PERFORMANCE OF BUILDINGS - VENTILATION FOR BUILDINGS - PART 5-2: CALCULATION METHODS FOR ENERGY REQUIREMENTS OF VENTILATION SYSTEMS (MODULES M5-6, M5-8, M6-5, M6-8, M7-5, M7-8) - METHOD 2: DISTRIBUTION AND GENERATION |
DIN EN 16798-5-2:2015-06 (Draft) | ENERGY PERFORMANCE OF BUILDINGS - VENTILATION FOR BUILDINGS - PART 5-2: CALCULATION METHODS FOR ENERGY REQUIREMENTS OF VENTILATION SYSTEMS (MODULES M5-6, M5-8, M6-5, M6-8, M7-5, M7-8) - METHOD 2: DISTRIBUTION AND GENERATION |
EN 15232-1:2017 | Energy Performance of Buildings - Energy performance of buildings - Part 1: Impact of Building Automation, Controls and Building Management - Modules M10-4,5,6,7,8,9,10 |
18/30367193 DC : 0 | BS EN 17213 - WINDOWS AND DOORS - ENVIRONMENTAL PRODUCT DECLARATIONS - PRODUCT CATEGORY RULES FOR WINDOWS AND PEDESTRIAN DOORSETS |
I.S. EN 15232-1:2017 | ENERGY PERFORMANCE OF BUILDINGS - ENERGY PERFORMANCE OF BUILDINGS - PART 1: IMPACT OF BUILDING AUTOMATION, CONTROLS AND BUILDING MANAGEMENT - MODULES M10-4, 5, 6, 7, 8, 9, 10 |
EN 16798-5-1:2017 | Energy performance of buildings - Ventilation for buildings - Part 5-1: Calculation methods for energy requirements of ventilation and air conditioning systems (Modules M5-6, M5-8, M6-5, M6-8, M7-5, M7-8) - Method 1: Distribution and generation |
EN 16798-15:2017 | Energy performance of buildings - Ventilation for buildings - Part 15: Calculation of cooling systems (Module M4-7) - Storage |
EN 16947-1:2017 | Energy Performance of Buildings - Building Management System - Part 1: Module M10-12 |
EN 16798-7:2017 | Energy performance of buildings - Ventilation for buildings - Part 7: Calculation methods for the determination of air flow rates in buildings including infiltration (Modules M5-5) |
BS EN 16798-7:2017 | Energy performance of buildings. Ventilation for buildings Calculation methods for the determination of air flow rates in buildings including infiltration (Modules M5-5) |
PREN 17213 : DRAFT 2018 | WINDOWS AND DOORS - ENVIRONMENTAL PRODUCT DECLARATIONS - PRODUCT CATEGORY RULES FOR WINDOWS AND PEDESTRIAN DOORSETS |
BS EN 16947-1:2017 | Energy Performance of Buildings. Building Management System Module M10-12 |
BS EN 16798-5-1:2017 | Energy performance of buildings. Ventilation for buildings Calculation methods for energy requirements of ventilation and air conditioning systems (Modules M5-6, M5-8, M6-5, M6-8, M7-5, M7-8). Method 1: Distribution and generation |
DIN EN 16798-5-2:2017-11 | ENERGY PERFORMANCE OF BUILDINGS - VENTILATION FOR BUILDINGS - PART 5-2: CALCULATION METHODS FOR ENERGY REQUIREMENTS OF VENTILATION SYSTEMS (MODULES M5-6, M5-8, M6-5, M6-8, M7-5, M7-8) - METHOD 2: DISTRIBUTION AND GENERATION |
ISO 13789:2017 | Thermal performance of buildings — Transmission and ventilation heat transfer coefficients — Calculation method |
CEN/TS 16629:2014 | Energy Performance of Buildings - Detailed Technical Rules for the set of EPB-standards |
ISO 13792:2012 | Thermal performance of buildings Calculation of internal temperatures of a room in summer without mechanical cooling Simplified methods |
EN 673:2011 | Glass in building - Determination of thermal transmittance (U value) - Calculation method |
CEN/TS 16628:2014 | Energy Performance of Buildings - Basic Principles for the set of EPB standards |
ISO 9488:1999 | Solar energy Vocabulary |
EN 410:2011 | Glass in building - Determination of luminous and solar characteristics of glazing |
ISO 52022-3:2017 | Energy performance of buildings — Thermal, solar and daylight properties of building components and elements — Part 3: Detailed calculation method of the solar and daylight characteristics for solar protection devices combined with glazing |
ISO 15927-4:2005 | Hygrothermal performance of buildings — Calculation and presentation of climatic data — Part 4: Hourly data for assessing the annual energy use for heating and cooling |
ISO 15099:2003 | Thermal performance of windows, doors and shading devices — Detailed calculations |
EN 15265:2007 | Energy performance of buildings - Calculation of energy needs for space heating and cooling using dynamic methods - General criteria and validation procedures |
ISO 52000-1:2017 | Energy performance of buildings — Overarching EPB assessment — Part 1: General framework and procedures |
ISO 52017-1:2017 | Energy performance of buildings — Sensible and latent heat loads and internal temperatures — Part 1: Generic calculation procedures |
ISO 15927-5:2004 | Hygrothermal performance of buildings Calculation and presentation of climatic data Part 5: Data for design heat load for space heating |
ISO 52010-1:2017 | Energy performance of buildings — External climatic conditions — Part 1: Conversion of climatic data for energy calculations |
ISO/TR 52016-2:2017 | Energy performance of buildings Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads Part 2: Explanation and justification of ISO 52016-1 and ISO 52017-1 |
ISO/TR 52019-2:2017 | Energy performance of buildings Hygrothermal performance of building components and building elements Part 2: Explanation and justification |
ISO 9050:2003 | Glass in building — Determination of light transmittance, solar direct transmittance, total solar energy transmittance, ultraviolet transmittance and related glazing factors |
EN 12831-1:2017 | Energy performance of buildings - Method for calculation of the design heat load - Part 1: Space heating load, Module M3-3 |
ISO 13786:2017 | Thermal performance of building components — Dynamic thermal characteristics — Calculation methods |
ISO 13370:2017 | Thermal performance of buildings — Heat transfer via the ground — Calculation methods |
ISO/TR 52000-2:2017 | Energy performance of buildings Overarching EPB assessment Part 2: Explanation and justification of ISO 52000-1 |
ISO 13791:2012 | Thermal performance of buildings Calculation of internal temperatures of a room in summer without mechanical cooling General criteria and validation procedures |
EN 14351-1:2006+A2:2016 | Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets |
ISO 15927-2:2009 | Hygrothermal performance of buildings Calculation and presentation of climatic data Part 2: Hourly data for design cooling load |
EN 15255:2007 | Energy performance of buildings - Sensible room cooling load calculation - General criteria and validation procedures |
ISO 6946:2017 | Building components and building elements — Thermal resistance and thermal transmittance — Calculation methods |
ISO 10077-1:2017 | Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 1: General |
ISO 13790:2008 | Energy performance of buildings Calculation of energy use for space heating and cooling |
ASHRAE 140 : 2014 | METHOD OF TEST FOR THE EVALUATION OF BUILDING ENERGY ANALYSIS COMPUTER PROGRAMS |
ISO 7345:1987 | Thermal insulation Physical quantities and definitions |
ISO 10292:1994 | Glass in building — Calculation of steady-state U values (thermal transmittance) of multiple glazing |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.